Racial Differences in Detection of Glaucoma Using Retinal Nerve Fiber Layer Thickness and Bruch Membrane Opening Minimum Rim Width

被引:5
|
作者
El-Nimri, Nevin W. [1 ,2 ,3 ]
Moghimi, Sasan [1 ,2 ,3 ]
Nishida, Takashi [1 ,2 ,3 ]
Yarmohammadi, Adeleh [1 ,2 ,3 ]
Zangwill, Linda M. [1 ,2 ,3 ]
Hou, Huiyuan [1 ,2 ,3 ]
Proudfoot, James [1 ,2 ,3 ]
Walker, Evan [1 ,2 ,3 ]
Fazio, Massimo A. [4 ]
Girkin, Christopher A. [4 ]
Liebmann, Jeffrey M. [5 ]
Weinreb, Robert N. [1 ,2 ,3 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Shiley Eye Inst, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Viterbi Family Dept Ophthalmol, La Jolla, CA 92093 USA
[4] Univ Alabama Birmingham, Dept Ophthalmol & Visual Sci, Heersink Sch Med, Birmingham, AL USA
[5] Columbia Univ Irving Med Ctr, Edward S Harkness Eye Inst, Dept Ophthalmol, Bernard & Shirlee Brown Glaucoma Res Lab, New York, NY USA
关键词
OPEN-ANGLE GLAUCOMA; OPTICAL COHERENCE TOMOGRAPHY; SCANNING LASER OPHTHALMOSCOPY; OCULAR HYPERTENSION TREATMENT; NEURORETINAL RIM; NORMATIVE DATABASE; DISC TOPOGRAPHY; PREVALENCE; WHITE; RACE;
D O I
10.1016/j.ajo.2022.10.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the sensitivities and specificities of the retinal nerve fiber layer thickness (RNFLT) and Bruch membrane opening minimum rim width (BMOMRW) reference database-based criteria for detection of glaucoma in individuals of European descent (ED) and individuals of African descent (AD). DESIGN: Comparative diagnostic analysis by race METHODS: 382 eyes of 255 glaucoma patients (ED = 170, AD = 85) and 94 eyes of 50 healthy individuals (ED = 30, AD = 20) with global and sectoral RNFLT and BMO-MRW measured with Spectralis optical coherence tomography (OCT) were included. Six diagnostic criteria were evaluated: global measurement below the 5th or 1st percentile, =1 of the 6 sector measurements below the 5th or 1st percentile, and superotemporal (ST) and/or inferotemporal (IT) measurement below the 5th or 1st percentile. The sensitivities and specificities of these measurements for detection of glaucoma were compared using bootstrapping methods. RESULTS: ST and/or IT RNFLT below the 5th percentile has the best performance for detection of glaucoma among RNFLT classifications with a sensitivity (95% CI) of 89.5% (86.1, 92.5) and specificity of 87.2% (77.8, 95.1). In AD individuals, sensitivities of ST and IT RNFLT and BMO-MRW measurements below the 5th percentile criteria were lower than in ED individuals (RNFLT: 83.7% vs 92.5%, and BMO-MRW: 72.1% vs 88.5%, respectively), as well as specificities (AD RNFLT: 73.7% and BMO-MRW: 89.5% vs ED RNFLT: 96.4% and BMO-MRW: 98.2%, respectively). CONCLUSIONS: RNFLT and BMO-MRW had consistently lower diagnostic performance in AD individuals compared with ED individuals. BMO-MRW criteria might fail to detect as many as one-third of eyes with glaucoma, specifically in AD individuals. With the current reference database, RNFLT, and especially BMO-MRW, criteria are not adequate for diagnosing glaucoma in AD individuals. (Am J Ophthalmol 2023;246: 223-235. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:223 / 235
页数:13
相关论文
共 50 条
  • [1] Racial differences in detection of glaucoma using retinal nerve fiber layer thickness and neuroretinal minimum rim width
    Yarmohammadi, Adeleh
    Moghimi, Sasan
    Zangwill, Linda
    Hou, Huiyuan
    Proudfoot, James
    Bowd, Christopher
    Massimo, Fazio
    Michael, Haft
    Carlos, De Moraes Gustavo
    Girkin, Christopher
    Leibmann, Jeffrey M.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)
  • [2] Bruch membrane opening-minimum rim width and retinal nerve fiber layer thickness in myopic children
    Gedik, Ali Ceyhun
    Ozbilen, Kemal Turgay
    Bayraktar, Serife
    Altinkurt, Emre
    Izgi, Belgin
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2021, 36
  • [3] Comparison of Bruch's Membrane Opening Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness in Early Glaucoma Assessment
    Gmeiner, Jonas M. D.
    Schrems, Wolfgang A.
    Mardin, Christian Y.
    Laemmer, Robert
    Kruse, Friedrich E.
    Schrems-Hoesl, Laura M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT575 - OCT584
  • [4] Sources of Discrepancy between Retinal Nerve Fiber Layer and Bruch's Membrane Opening-Minimum Rim Width Thickness in Eyes with Glaucoma
    Zhuang, Iris
    Ashrafkhorasani, Maryam
    Mohammadzadeh, Vahid
    Nouri-Mahdavi, Kouros
    OPHTHALMOLOGY SCIENCE, 2025, 5 (01):
  • [5] Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a Brazilian population of healthy subjects
    Zangalli, Camila S.
    Vianna, Jayme R.
    Reis, Alexandre S. C.
    Miguel-Neto, Jamil
    Burgoyne, Claude F.
    Chauhan, Balwantray C.
    Costa, Vital P.
    PLOS ONE, 2018, 13 (12):
  • [6] Accuracy of Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size
    Englmaier, Verena Anna
    Storp, Jens Julian
    Leclaire, Martin Dominik
    Lahme, Larissa
    Bruecher, Viktoria Constanze
    Biermann, Julia
    Diener, Raphael
    Eter, Nicole
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1899 - 1910
  • [7] Comparison of retinal nerve fiber layer thickness and Bruch’s membrane opening minimum rim width thinning rate in open-angle glaucoma
    Donghee Park
    Sung Pyo Park
    Kyeong Ik Na
    Scientific Reports, 12
  • [8] Accuracy of Bruch’s membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size
    Verena Anna Englmaier
    Jens Julian Storp
    Martin Dominik Leclaire
    Larissa Lahme
    Viktoria Constanze Brücher
    Julia Biermann
    Raphael Diener
    Nicole Eter
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1899 - 1910
  • [9] Comparison of retinal nerve fiber layer thickness and Bruch's membrane opening minimum rim width thinning rate in open-angle glaucoma
    Park, Donghee
    Park, Sung Pyo
    Na, Kyeong Ik
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Bruch Membrane Opening Minimum Rim Width and Retinal Nerve Fiber Layer Helps Differentiate Compressive Optic Neuropathy From Glaucoma
    Andrade, Thais de Souza
    de Araujo, Rafael Barbosa
    do Nascimento Rocha, Arthur Andrade
    Marchesi Mello, Luiz Guilherme
    Cunha, Leonardo P.
    Monteiro, Mario L. R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 234 : 156 - 165