Evaluation of an early-stage prototype polyurethane femoral head implant for hip arthroplasty

被引:3
|
作者
Siroros, Nad [1 ,2 ,3 ]
Merfort, Ricarda [1 ]
Migliorini, Filippo [1 ,4 ]
Lecouturier, Sophie [1 ]
Leven, Sophia [1 ]
Praster, Maximilian [1 ]
Hildebrand, Frank [1 ]
Eschweiler, Jorg [5 ]
机构
[1] Univ Med Ctr RWTH Aachen, Dept Orthopaed Trauma & Reconstruct Surg, Aachen, Germany
[2] Chiang Mai Univ, Biomed Engn Inst, Chiang Mai, Thailand
[3] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai, Thailand
[4] Acad Hosp Bolzano SABES ASDAA, Teaching Hosp Paracelsus Med Univ PMU, Dept Orthopaed & Trauma Surg, I-39100 Bolzano, Italy
[5] BG Hosp Bergmannstrost, Dept Trauma & Reconstruct Surg, Halle An Der Saale, Germany
关键词
Bearings; Implant; Hip arthroplasty; Polyurethane; ALAMAR BLUE; ARTICULAR-CARTILAGE; THICKNESS;
D O I
10.1016/j.jor.2023.11.067
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Thi study evalautes a new bone-preserving femoral head cover that mimics the articular cartilage of the femoral head.Methods A specially developed polyurethane (PU) was evaluated in biocompatibility (cytotoxicity test) and mechanical response to tensile loading. In the cytotoxicity test, steam sterilized (SS) and ethylene oxide sterilized (EtO) PU samples were incubated separately in a cell culture medium. The seeded cell line MG-63 was then added to these sample-incubated cell culture mediums. One negative control group and one positive control group were also evaluated. The cells in each group were cultured for seven days before being quantified using the alamarBlue assay. In the mechanical test, the femoral head cover implants were separated into three groups of three samples. Each group represented a different implant insertion idea: direct insertion (uc sample) and another two insertion modes (is and ss samples) representing implants with enclosure mechanisms. The test consisted of distance-controlled cyclic tensile loadings followed by a failure test.Results The cytotoxicity test results show no significant difference in fluorescence intensity between the negative control, the three SS groups, and one EtO group (P > 0.05). However, the other two EtO groups exhibit significantly lower fluorescence intensity compared with the negative control (P < 0.05). In the mechanical test, the is samples have the highest cyclic loading force at 559.50 +/- 51.41 N, while the uc samples exhibit the highest force in the failure test at 632.16 +/- 50.55 N. There are no significant differences (P > 0.05) among the uc, is, and ss groups in terms of stiffness.Conclusion The cytotoxicity test and the mechanical experiment provide initial assessments of the proposed PU femoral head cover implant. The evaluation outcomes of this study could serve as a foundation for developing more functional design and testing methods, utilizing numerical simulations, and developing animal/clinical trials in the future.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [31] Influence of the femoral head size on early postoperative gait restoration after total hip arthroplasty
    Zhou Yi-xin
    Guo Sheng-jie
    Liu Qing
    Tang Jing
    Li Yu-jun
    CHINESE MEDICAL JOURNAL, 2009, 122 (13) : 1513 - 1516
  • [32] Hip resurfacing arthroplasty for osteonecrosis of the femoral head: Implant-speci fic outcomes and risk factors for failure
    Park, Chan-Woo
    Lim, Seung-Jae
    Kim, Joo-Hwan
    Park, Youn-Soo
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 21 : 41 - 48
  • [33] Short-stem hip arthroplasty in osteonecrosis of the femoral head
    Floerkemeier, Thilo
    Budde, Stefan
    Gronewold, Jens
    Radtke, Kerstin
    Ettinger, Max
    Windhagen, Henning
    von Lewinski, Gabriela
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (05) : 715 - 722
  • [34] Dislocations and the femoral head size in primary total hip arthroplasty
    Hedlundh, U
    Ahnfelt, L
    Hybbinette, CH
    Wallinder, L
    Weckstrom, J
    Fredin, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (333) : 226 - 233
  • [35] DISTRACTION ARTHROPLASTY OF THE HIP BY BICENTRIC FEMORAL-HEAD PROSTHESIS
    ITO, T
    NAKAYAMA, Y
    TANAKA, H
    ISHIDA, K
    MASUDA, K
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (255) : 186 - 193
  • [36] Hip Resurfacing Arthroplasty in Treatment of Avascular Necrosis of the Femoral Head
    Pyda, Michal
    Koczy, Bogdan
    Widuchowski, Wojciech
    Widuchowska, Malgorzata
    Stoltny, Tomasz
    Mielnik, Michal
    Hermanson, Jacek
    MEDICAL SCIENCE MONITOR, 2015, 21 : 304 - 309
  • [37] Femoral head diameter considerations for primary total hip arthroplasty
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (01) : S25 - S29
  • [38] BLEEDING OF FEMORAL HEAD DURING TOTAL HIP ARTHROPLASTY FOR OSTEOARTHROSIS
    Schwartsmann, Carlos Roberto
    Spinelli, Leandro de Freitas
    Sotomayor, Marco Yanez
    Yepez, Anthony Kerbes
    Boschin, Leonardo Carbonera
    Silva, Marcelo Faria
    ACTA ORTOPEDICA BRASILEIRA, 2015, 23 (05): : 268 - 270
  • [39] Osteonecrosis of the femoral head treated with cementless total hip arthroplasty
    Hartley, WT
    McAuley, JP
    Culpepper, WJ
    Engh, CA
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10): : 1408 - 1413
  • [40] Short-stem hip arthroplasty in osteonecrosis of the femoral head
    Thilo Floerkemeier
    Stefan Budde
    Jens Gronewold
    Kerstin Radtke
    Max Ettinger
    Henning Windhagen
    Gabriela von Lewinski
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 715 - 722