Evaluation of an early-stage prototype polyurethane femoral head implant for hip arthroplasty

被引:2
|
作者
Siroros, Nad [1 ,2 ,3 ]
Merfort, Ricarda [1 ]
Migliorini, Filippo [1 ,4 ]
Lecouturier, Sophie [1 ]
Leven, Sophia [1 ]
Praster, Maximilian [1 ]
Hildebrand, Frank [1 ]
Eschweiler, Jorg [5 ]
机构
[1] Univ Med Ctr RWTH Aachen, Dept Orthopaed Trauma & Reconstruct Surg, Aachen, Germany
[2] Chiang Mai Univ, Biomed Engn Inst, Chiang Mai, Thailand
[3] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai, Thailand
[4] Acad Hosp Bolzano SABES ASDAA, Teaching Hosp Paracelsus Med Univ PMU, Dept Orthopaed & Trauma Surg, I-39100 Bolzano, Italy
[5] BG Hosp Bergmannstrost, Dept Trauma & Reconstruct Surg, Halle An Der Saale, Germany
关键词
Bearings; Implant; Hip arthroplasty; Polyurethane; ALAMAR BLUE; ARTICULAR-CARTILAGE; THICKNESS;
D O I
10.1016/j.jor.2023.11.067
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Thi study evalautes a new bone-preserving femoral head cover that mimics the articular cartilage of the femoral head.Methods A specially developed polyurethane (PU) was evaluated in biocompatibility (cytotoxicity test) and mechanical response to tensile loading. In the cytotoxicity test, steam sterilized (SS) and ethylene oxide sterilized (EtO) PU samples were incubated separately in a cell culture medium. The seeded cell line MG-63 was then added to these sample-incubated cell culture mediums. One negative control group and one positive control group were also evaluated. The cells in each group were cultured for seven days before being quantified using the alamarBlue assay. In the mechanical test, the femoral head cover implants were separated into three groups of three samples. Each group represented a different implant insertion idea: direct insertion (uc sample) and another two insertion modes (is and ss samples) representing implants with enclosure mechanisms. The test consisted of distance-controlled cyclic tensile loadings followed by a failure test.Results The cytotoxicity test results show no significant difference in fluorescence intensity between the negative control, the three SS groups, and one EtO group (P > 0.05). However, the other two EtO groups exhibit significantly lower fluorescence intensity compared with the negative control (P < 0.05). In the mechanical test, the is samples have the highest cyclic loading force at 559.50 +/- 51.41 N, while the uc samples exhibit the highest force in the failure test at 632.16 +/- 50.55 N. There are no significant differences (P > 0.05) among the uc, is, and ss groups in terms of stiffness.Conclusion The cytotoxicity test and the mechanical experiment provide initial assessments of the proposed PU femoral head cover implant. The evaluation outcomes of this study could serve as a foundation for developing more functional design and testing methods, utilizing numerical simulations, and developing animal/clinical trials in the future.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] An Evaluation of Core Decompression and Cancellous Bone Grafting for Early-Stage Avascular Necrosis of the Femoral Head
    Singh, Harpreet
    Agarwal, Kamal Kumar
    Tyagi, Sangam
    Rampurwala, Ammar
    Singh, Amritesh
    Bhrambhatt, Purvesh
    Unjia, Rishit
    Agarwal, Neel
    Rampurwala, Aliasgar J.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [2] The Relationship of the Canine Femoral Head to the Femoral Neck: An Anatomic Study with Relevance for Hip Arthroplasty Implant Design and Implantation
    Franklin, Samuel P.
    Franklin, Ashley L.
    Wilson, Howard
    Schultz, Loren
    Bal, B. Sonny
    Cook, James L.
    VETERINARY SURGERY, 2012, 41 (01) : 86 - 93
  • [3] PROSTHETIC FEMORAL HEAD ARTHROPLASTY OF THE HIP JOINT
    CAMERON, GW
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1954, 71 (06) : 580 - 584
  • [4] One-stage Hip Arthroplasty and Bone Grafting for Bilateral Femoral Head Osteonecrosis
    Shih, Lih-Yuann
    Wong, Yon-Cheong
    Shih, Hsin-Nung
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (06) : 1522 - 1528
  • [5] Impact of implant design on femoral head hemiresurfacing arthroplasty
    Grecula, MJ
    Thomas, JA
    Kreuzer, SW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (418) : 41 - 47
  • [6] Investigations of Cartilage Matrix Degeneration in Patients with Early-Stage Femoral Head Necrosis
    Xu, Ronghua
    Wei, Bo
    Li, Jiayi
    Huang, Chenyu
    Lin, Rongcai
    Tang, Cheng
    Xu, Yan
    Yao, Qingqiang
    Wang, Liming
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5783 - 5792
  • [7] Early Disassembly of Femoral Head and Neck Components After Total Hip Arthroplasty Revision
    Tutuncu, Mehmed Nuri
    Karaismailoglu, Bedri
    Sahin, Erdem
    Karaismailoglu, Turgut Nedim
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
  • [8] Blood flow to the femoral head and hip resurfacing arthroplasty
    Beaule, P. E.
    Ganz, R.
    Leunig, M.
    ORTHOPADE, 2008, 37 (07): : 659 - 666
  • [9] Hip Arthroplasty How much of the femoral head is opened?
    Preuss, Roman
    Flohr, Markus
    Bertmaring, Hendrik
    Haeussler, Kim Lars
    Wirtz, Dieter C.
    Trieb, Klemens
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2012, 150 (04): : 351 - 351
  • [10] Femoral head fractures: hemiarthroplasty or total hip arthroplasty?
    Ullmark, Gosta
    HIP INTERNATIONAL, 2014, 24 : S12 - S14