Embolic Stroke of Undetermined Source: Role of Implantable Loop Recorder in Secondary Prevention.

被引:0
|
作者
Gambino, Andrea [1 ]
Ravetti, Emanuele [2 ]
Naldi, Andrea [3 ]
Russo, Riccardo [4 ]
Molinaro, Stefano [4 ]
Mistretta, Francesco [1 ]
Jorfida, Marcella [2 ]
Castagno, Davide [2 ]
De Ferrari, Gaetano Maria [2 ]
Cerrato, Paolo [5 ]
Bosco, Giovanni [5 ]
D'Agata, Federico [6 ]
Cicerale, Alessandro [6 ]
Bergui, Mauro [4 ]
机构
[1] Univ Turin, Azienda Osped Citta Salute & Sci Hosp, Dept Surg Sci, Radiol Unit, Turin, Italy
[2] Azienda Osped Univ Citta Salute & Sci Torino, Cardiovasc & Thorac Dept, Turin, Italy
[3] San Giovanni Bosco Hosp, Dept Neurosci, Neurol Unit, Turin, Italy
[4] Univ Turin, Azienda Osped Citta Salute & Sci Hosp, Dept Neurosci, Neuroradiol Unit, Turin, Italy
[5] Azienda Osped Univ Citta Salute & Sci Torino, Dept Neurol, Stroke Unit, Turin, Italy
[6] Univ Turin, Dept Neurosci, Turin, Italy
关键词
Embolic stroke of undetermined source; Atrial fibrillation; Implantable loop recorder; Secondary prevention; Stroke recurrence; RANDOMIZED-TRIAL RATIONALE;
D O I
10.1017/cjn.2022.66
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Aims: Atrial fibrillation (AF) is the most important cause of embolic stroke of undetermined source (ESUS). Implantable loop recorder (ILR) demonstrated the highest sensitivity for detecting it. This register was created to confirm the high prevalence of AF in patients after ESUS and to verify possible benefits on clinical outcomes such as TIA (Transient Ischaemic Attack)/stroke recurrence and death using ILR. Methods: A total of 278 patients admitted to "Molinette" Hospital in Stroke Unit department between 2011 and 2016, diagnosed with ESUS, underwent ILR implantation if they had at least one risk factor for AF. A total of 165 patients admitted to other departments in the same center for the same pathology, without ILR, represent the control group. We used propensity score to select 132 patients from each group (matching age, sex, CHADS-VASC, and HAS-BLEED baseline characteristics). Results: The detection rate of AF episodes was significantly higher in the ILR group (p < 0.001). No significant protective role of ILR for clinical endpoints was found on univariate analysis, although a trend towards significance has been pointed for the composite outcome of death and ischemic events recurrence (OR 0.52, CI 0.26-1.04, p = 0.06). A protective role of ILR was found for deaths (OR 0.4, CI 0.17-0.94, p 0.03) and for the composite outcome (OR 0.41, CI 0.19-0.87, p 0.02) on multivariate analysis in the best subsets. Conclusion: With our statistical models, we identified a significant clinical benefit from ILR monitoring, evidenced by a trend of less death and TIA/stroke recurrence and relevant ILR protection for prediction of TIA/stroke recurrence.
引用
收藏
页码:529 / 534
页数:6
相关论文
共 50 条
  • [31] Atrial fibrillation detection in patients with an implantable loop recorder after acute embolic stroke of unknown source (ESUS)
    Kitsiou, A.
    Kalyani, M.
    Ejangue, L. Ekosso
    Hagemeister, C.
    Manegold, J.
    Israel, C.
    Schaebitz, W.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 273 - 273
  • [32] Atrial Fibrillation Detection in Patients With an Implantable Loop Recorder After Acute Embolic Stroke of Unknown Source (ESUS)
    Kitsiou, Alkisti
    Kalyani, Malik
    Ejangue, Ekosso Lucy
    Hagemeister, Christoph
    Manegold, Johannes
    Israel, Carsten
    Schaebitz, Wolf-Ruediger
    STROKE, 2016, 47
  • [33] Impact of a Stroke Physician-Provided Loop Recorder Implant Service in a Model 3 Hospital Investigating Embolic Stroke of Undetermined Source
    Zeeshan, Muhammad
    O'Sullivan, Ciara
    Coghlan, Roseann
    Flahive, Ann
    McCormick, John
    Cotter, Paul
    AGE AND AGEING, 2024, 53
  • [34] Association between implantable loop recorder use and secondary stroke prevention: a meta-analysis
    Huang, Wen-Yi
    Ovbiagele, Bruce
    Hsieh, Cheng-Yang
    Lee, Meng
    OPEN HEART, 2022, 9 (01):
  • [35] Embolic stroke of undetermined source: The role of the nonstenotic carotid plaque
    Bulwa, Zachary
    Gupta, Ajay
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 382 : 49 - 52
  • [36] THE ROLE OF ECHOCARDIOGRAPHY IN THE DIAGNOSIS AND MANAGEMENT OF EMBOLIC STROKE OF UNDETERMINED SOURCE
    Ziada, S.
    Messelmani, M.
    Derbali, H.
    Mansour, M.
    Bedoui, I.
    Zaouali, J.
    Mrissa, R.
    INTERNATIONAL JOURNAL OF STROKE, 2022, 17 (3_SUPPL) : 288 - 288
  • [37] Is Embolic Stroke of Undetermined Source Shrinking?
    Tirschwell, David L.
    Taylor, Breana L.
    STROKE, 2019, 50 (09) : 2290 - 2291
  • [38] Cancer and Embolic Stroke of Undetermined Source
    Navi, Babak B.
    Kasner, Scott E.
    Elkind, Mitchell S., V
    Cushman, Mary
    Bang, Oh Young
    DeAngelis, Lisa M.
    STROKE, 2021, 52 (03) : 1121 - 1130
  • [39] Early atrial fibrillation detection is associated with higher arrhythmic burden in patients with loop recorder after an embolic stroke of undetermined source
    Capocci, Sofia
    Tomasi, Luca
    Zivelonghi, Cecilia
    Bolzan, Bruna
    Berton, Giampaolo
    Strazzanti, Mattia
    Franchi, Elena
    Tomei, Ruggero
    Vassanelli, Francesca
    Cappellari, Manuel
    Ribichini, Flavio Luciano
    Mugnai, Giacomo
    INTERNATIONAL JOURNAL OF CARDIOLOGY CARDIOVASCULAR RISK AND PREVENTION, 2023, 17
  • [40] Sex-based comparisons of clinical characteristics and outcomes of patients with embolic stroke of undetermined source with implantable loop recorders
    Low, C. H. X.
    Ong, J. S. P.
    Li, T. Y. W.
    Ho, J. S. Y.
    Sharma, V. K.
    Tan, B. Y. Q.
    Seow, S. C.
    Yeo, L. L. L.
    Yeo, T. C.
    Chai, P.
    Chan, M. Y. Y.
    Sia, C. H.
    EUROPEAN HEART JOURNAL, 2023, 44 : 105 - 105