Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Development, optimization and validation of an analytical method for the determination of voriconazole in plasma by high-performance liquid chromatography-ultraviolet detection: Application for comprehensive study
    Berriri, Sarra
    Zribi, Kaouther
    Gloulou, Olfa
    Mokni, Yassine
    Safta, Fathi
    ANNALES PHARMACEUTIQUES FRANCAISES, 2024, 82 (05): : 886 - 897
  • [22] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma
    Ahmadi-Jouibari, Toraj
    Fattahi, Nazir
    Shamsipur, Mojtaba
    Pirsaheb, Meghdad
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 85 : 14 - 20
  • [23] On-line solid-phase microextraction of triclosan, bisphenol A, chlorophenols, and selected pharmaceuticals in environmental water samples by high-performance liquid chromatography-ultraviolet detection
    Kim, Dalho
    Han, Jungho
    Choi, Yongwook
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 377 - 387
  • [24] Simultaneous determination of nitroimidazole residues in honey samples by high-performance liquid chromatography with ultraviolet detection
    Zhou, Jinhui
    Shen, Jianzhong
    Xue, Xiaofeng
    Zhao, Jing
    Li, Yi
    Zhang, Jinzhen
    Zhang, Suxia
    Journal of AOAC International, 1600, 90 (03): : 872 - 878
  • [25] The Simultaneous Determination of Ibuprofen and Paracetamol in Pharmaceutical Formulations by High-performance Liquid Chromatography with Ultraviolet Detection
    Alsaad, Ahmed A. A.
    Alassadi, Erfan A. S.
    Al-Salman, H. N. K.
    Hussein, Hussein H.
    ASIAN JOURNAL OF PHARMACEUTICS, 2019, 13 (02) : 141 - 152
  • [26] Simultaneous determination of nitroimidazole residues in honey samples by high-performance liquid chromatography with ultraviolet detection
    Zhou, Jinhui
    Shen, Jianzhong
    Xue, Xiaofeng
    Zhao, Jing
    Li, Yi
    Zhang, Jinzhen
    Zhang, Suxia
    JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (03) : 872 - 878
  • [27] Simultaneous determination of tricarboxylic acid cycle metabolites by high-performance liquid chromatography with ultraviolet detection
    Shurubor, Yevgeniya I.
    Cooper, Arthur J. L.
    Isakova, Elena P.
    Deryabina, Yulia I.
    Beal, M. Flint
    Krasnikov, Boris F.
    ANALYTICAL BIOCHEMISTRY, 2016, 503 : 8 - 10
  • [28] Simultaneous determination of five systemic azoles in plasma by high-performance liquid chromatography with ultraviolet detection
    Gordien, Jean-Baptiste
    Pigneux, Arnaud
    Vigouroux, Stephane
    Tabrizi, Reza
    Accoceberry, Isabelle
    Bernadou, Jean-Marc
    Rouault, Audrey
    Saux, Marie-Claude
    Breilh, Dominique
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 932 - 938
  • [29] A SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR SEPARATION OF BENZO(A)PYRENE METABOLITES
    ELNENAEY, E
    SCHOOR, WP
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1099 - 1099
  • [30] Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
    de Andrade, MCC
    Di Marco, GS
    Felipe, CR
    Alfieri, F
    Júnior, HTS
    Pestana, JOM
    Casarini, DE
    TRANSPLANT INTERNATIONAL, 2005, 18 (03) : 354 - 359