Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Simple High-Performance Liquid Chromatography-Ultraviolet Method To Quantify the Molecular Size Distribution of Nonylphenol Ethoxylates
    Arturi, Tatiana S.
    Zaritzky, Noemi E.
    Contreras, Edgardo M.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (04) : 1327 - 1333
  • [2] Simultaneous determination of selected ionophoric coccidiostats and amino acids in feed premixes using high-performance liquid chromatography-ultraviolet detection method
    Zayed, Sahar
    Belal, Fathalla
    Barghash, Sona
    Fouad, Fatma
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (04)
  • [3] A simple method for quantification of voriconazole by high-performance liquid chromatography with ultraviolet-detection
    Yamada, T.
    Suzuki, K.
    Urashima, Y.
    Kato, R.
    Ijiri, Y.
    Nishihara, M.
    Tanaka, K.
    Takiuchi, H.
    Tamai, H.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 519 - 519
  • [4] Chemical profiling of floral and chestnut honey using high-performance liquid chromatography-ultraviolet detection
    Aloglu, Ahmet Kemal
    Harrington, Peter de B.
    Sahin, Saliha
    Demir, Cevdet
    Gunes, Mesut Ertan
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2017, 62 : 205 - 210
  • [5] Analysis of CoQ10 in Cultivated Tobacco by a High-Performance Liquid Chromatography-Ultraviolet Method
    Stiff, Michael R.
    Weissinger, Arthur K.
    Danehower, David A.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (17) : 9054 - 9058
  • [6] An evaluation of the Abbott IMx sirolimus assay in relation to a high-performance liquid chromatography-ultraviolet method
    Johnson, RN
    Sargon, R
    Woollard, G
    Davidson, J
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 394 - 397
  • [7] A SIMPLE AND CONVENIENT METHOD FOR QUANTITATION OF CORTICOSTERONE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ULTRAVIOLET DETECTION
    YAMADA, K
    AIZAWA, Y
    JOURNAL OF PHARMACOLOGICAL METHODS, 1984, 11 (04): : 291 - 297
  • [8] Simultaneous determination of 9 flavored nucleotides in aquatic products by high performance liquid chromatography-ultraviolet method
    Shang, Xiaorui
    Chen, Rouhan
    Deng, Bo
    Tang, Yunyu
    Tian, Liangliang
    Li, Siman
    Ma, Yingqing
    Han, Yiyi
    Xu, Yilin
    Huang, Dongmei
    Feng, Dongsheng
    Chinese Journal of Analysis Laboratory, 2024, 43 (12) : 1763 - 1770
  • [9] A simple, sensitive high-performance liquid chromatography-ultraviolet method for the quantification of concentration and steady-state pharmacokinetics of itraconazole and hydroxyitraconazole
    Miura, M.
    Takahashi, N.
    Nara, M.
    Fujishima, N.
    Kagaya, H.
    Kameoka, Y.
    Saitoh, H.
    Tagawa, H.
    Sawada, K.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 432 - 439
  • [10] High-Performance Liquid Chromatography-Ultraviolet Detection Method for the Simultaneous Determination of Typical Biogenic Amines and Precursor Amino Acids. Applications in Food Chemistry
    Mazzucco, Eleonora
    Gosetti, Fabio
    Bobba, Marco
    Marengo, Emilio
    Robotti, Elisa
    Gennaro, Maria Carla
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (01) : 127 - 134