Effects of temperature and humidity ratio on the performance of desiccant dehumidification system under low-temperature regeneration

被引:6
|
作者
Yu, Hao [1 ]
Seo, Sang Won [1 ]
Miksik, Frantisek [2 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
Ng, Kim Choon [3 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] King Abdullah Univ Sci & Technol KAUST, Water Desalinat & Reuse Ctr WDRC, Thuwal 239556900, Saudi Arabia
关键词
Adsorption; Dehumidification; Desiccant; Low-temperature regeneration; Performance analysis; WATER-VAPOR; LIQUID DESICCANT; COOLING SYSTEM; SODIUM-SALT; SILICA-GEL; WASTE HEAT; ADSORPTION; ENERGY; ENVIRONMENT; SORBENTS;
D O I
10.1007/s10973-022-11368-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
The desiccant dehumidification system can separate the latent heat and sensible heat in the air-conditioning system and achieve energy savings by removing latent heat. Industrial waste heat and renewable energy could be utilized in desiccant dehumidification systems, where the desorption process can be performed below 70 degrees C. The vapor pressure and temperature of the regenerating air dictate the desorption process corresponding to the isotherm properties. This study has focused on the effects of various temperatures and humidity ratios of regeneration air on the performance of a desiccant dehumidifier using a polymer as an adsorbent. Experiments were performed using the regeneration air with the humidity ratios of 0.005 kg kg(-1), 0.010 kg kg(-1), 0.015 kg kg(-1), and 0.020 kg kg(-1), while the air temperatures were varied from 40 degrees C to 70 degrees C. The evaluation of this study employs the adsorption/desorption amount, average moisture removal capacity, and latent energy ratio (LER) of the regeneration process as key performance indexes. At the regeneration temperature of 68 degrees C, the peak desorption amount at the humidity ratio of 0.005 kg kg(-1) and 0.010 kg kg(-1) both reached 0.011 kg kg(-1). The results indicated that the higher desorption temperature led to a higher desorption amount. Besides, with the increased desorption temperature, the average moisture removal capacity increases. In contrast, the high humidity ratio of regeneration air resulted in a weak dehumidification ability. Lower regeneration temperature was difficult to apply to regenerate the polymer-based desiccant under a high-humidity-ratio atmosphere. To attain a high LER, a lower humidity ratio of dry air and regeneration temperature was preferred. The regeneration air with a humidity ratio of 0.020 kg kg(-1) is not suitable to apply in the dehumidification system in the temperature range of 40-70 degrees C.
引用
收藏
页码:3045 / 3058
页数:14
相关论文
共 50 条
  • [31] A review of photovoltaic thermal (PV/T) heat utilisation with low temperature desiccant cooling and dehumidification
    Guo, Jinyi
    Lin, Simao
    Bilbao, Jose I.
    White, Stephen D.
    Sproul, Alistair B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 1 - 14
  • [32] Study on the Alleviation of Performance Degradation and Voltage Stability of PEMFC by Adding Silica Under Low-Temperature and Low-Humidity Conditions
    Bai, Qiang
    Hsieh, Chuangyu
    Liu, Zhenghong
    Chen, Qipeng
    Weng, Fangbor
    CRYSTALS, 2024, 14 (12)
  • [33] Research of Low-temperature Regeneration of Waste EPDM
    Wang, Chuansheng
    Xie, Qingguo
    Bian, Huiguang
    PROGRESS IN POLYMER PROCESSING, 2012, 501 : 311 - 315
  • [34] The impact of wettability on the performance of a two row wavy fin and tube liquid desiccant system for dehumidification and regeneration
    Indrawan, Wisnu
    Lubis, Arnas
    Alhamid, M. I.
    APPLIED THERMAL ENGINEERING, 2024, 241
  • [35] INVESTIGATION OF LOW-TEMPERATURE REGENERATION OF ACTIVATED CARBON
    AMICARELLI, V
    BALDASSARRE, G
    LIBERTI, L
    JOURNAL OF THERMAL ANALYSIS, 1980, 18 (01): : 155 - 160
  • [36] EXPERIMENTAL STUDIES OF LOW-TEMPERATURE DRYING BY DEHUMIDIFICATION .2. EXPERIMENTAL
    TOAL, BR
    MORGAN, R
    MCMULLAN, JT
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1988, 12 (02) : 315 - 344
  • [37] LOW-TEMPERATURE REGENERATION OF ADSORBENTS IN-SITU
    FEDOROVA, MF
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY,USSR, 1970, 44 (06): : 830 - &
  • [38] DIVIDED FLOW, LOW-TEMPERATURE HUMIDITY TEST APPARATUS
    WEXLER, A
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1948, 40 (06): : 479 - 486
  • [39] Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature
    Ruivo, Celestino R.
    Goldsworthy, Mark
    Intini, Manuel
    ENERGY, 2014, 68 : 765 - 772
  • [40] Influence of plate surface temperature on the wetted area and system performance for falling film liquid desiccant regeneration system
    Qi, Ronghui
    Lu, Lin
    Yang, Hongxing
    Qin, Fei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 : 1003 - 1013