Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture

被引:1
|
作者
Kim, Jae Kwang [1 ]
Shin, Young Ho [1 ]
Kim, Minsoo [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Orthoped Surg, 88,Olymp Rd 43 Gil, Seoul 05505, South Korea
关键词
Volar locking plate; Distal radius fracture; Flexor tendon attrition; Ultrasound; HARDWARE REMOVAL; FIXATION; POSITION; RUPTURE; WRIST; TILT;
D O I
10.1007/s00402-022-04499-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction We classified the contact configuration between the volar prominence of volar locking plate (VLP) and flexor pollicis longus (FPL) tendon using ultrasound (US) into indentation contact and smooth contact, and investigated whether the contact configuration is associated with the flexor tendon attrition. Materials and methods Ninety-four patients who underwent VLP removal were included in this study. We assessed pain using visual analogue scale, grip strength, and Disabilities of the Arm, Shoulder and Hand score for clinical evaluations, radial inclination, palmar tilt, ulnar variance, and Soong classification for radiological evaluations, and contact configuration using US at 1 year after VLP fixation. After these evaluations, we removed the VLP with observation for the presence of fibrillation or wear of FPL tendon substance. Subsequently, we classified the patients into either of FPL attrition and FPL intact group. Results Twenty-eight patients had indentation contact configuration and 66 patients had smooth contact configuration. The kappa value for inter-observer reliability for the contact configuration was 0.78. Twelve patients were included in the FPL attrition group and 82 in the FPL intact group. There was no significant difference in clinical outcomes and Soong classification between the groups. However, palmar tilt of the flexor tendon attrition group was significantly lower than that of the flexor tendon intact group and the FPL attrition group showed significantly higher indentation contact configuration rate than the FPL intact group. FPL tendon attrition was diagnosed using the contact configuration on US with a sensitivity of 100% and specificity of 80%. Conclusion This study demonstrated that FPL tendon attrition was significantly associated with indentation contact on US with high sensitivity. Therefore, we recommend selective implant removal in patients with indentation contact configuration.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 50 条
  • [41] Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases
    Valbuena, S. E.
    Cogswell, L. K.
    Baraziol, R.
    Valenti, P.
    CHIRURGIE DE LA MAIN, 2010, 29 (02) : 109 - 113
  • [42] Flexor Pollicis Longus Tendon Wear Associated With Volar Plating: A Cadaveric Study
    Zelenski, Nicole A.
    Schmidt, Elaine
    Chin, Matthew
    Gittings, Daniel
    Steinberg, David
    Hast, Michael W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (02): : 106 - 113
  • [43] Usefulness of CT-based measurement of volar prominence for evaluation of risk of flexor tendon injury following fixation of a distal radius fracture
    Tokutake, Katsuhiro
    Iwatsuki, Katsuyuki
    Tatebe, Masahiro
    Okui, Nobuyuki
    Mizuno, Masanori
    Hirata, Hitoshi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (02) : 263 - 268
  • [44] EXTENSOR POLLICIS LONGUS TENDON RUPTURES AFTER THE USE OF VOLAR LOCKING PLATES FOR DISTAL RADIUS FRACTURES
    Zenke, Yukichi
    Sakai, Akinori
    Oshige, Toshihisa
    Moritani, Shiro
    Menuki, Kunitaka
    Yamanaka, Yoshiaki
    Furukawa, Kayoko
    Nakamura, Toshitaka
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2013, 18 (02): : 169 - 173
  • [45] Complications of Volar Plate for Distal Radius Fracture
    Nakamura, Toshiyasu
    JOURNAL OF WRIST SURGERY, 2023, 12 (05) : 383 - 383
  • [46] Predicting Flexor Tendon Complications Following Volar Plate Fixation of Distal Radius Fractures
    Yang, J.
    Parkes, R.
    Yip, C. R.
    Chojnowski, A.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [47] The Interobserver Reliability of Grading of Distal Radius Volar Plate Prominence
    Crijns, Tom J.
    Merkel, Patrick
    Kortlever, Joost T. P.
    Wagner III, K. John
    Ring, David
    Vagner, Gregg
    Teunis, Teun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (11): : 1095 - 1100
  • [48] Flexor tendon repair after rupture caused by volar plate fixation of the distal radius
    Rubensson, Carin C.
    Ydreborg, Karin
    Boren, Linda
    Karlander, Lars-Erik
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2015, 49 (02) : 112 - 115
  • [49] Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
    Lv, Yang-Xun
    Chen, Mang-Mang
    Su, Chen-Xian
    Ye, Hao-Nan
    Yang, Jie
    Li, Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (08)
  • [50] Letter Regarding "Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation" Reply
    Afshar, Ahmadreza
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (11): : 2303 - 2304