Adequate Silicone Oil Tamponade by Utilizing the Space of Anterior Segment for Complicated Retinal Detachment: Technique, Efficacy, and Safety

被引:2
|
作者
Wang, Yifan [1 ]
Huang, Zijing [1 ]
Zheng, Dezhi [1 ]
Liu, Juntao [1 ]
Huang, Dingguo [1 ]
Zheng, Jianlong [1 ]
Xie, Haixia [1 ]
Lin, Peimin [1 ]
Chen, Weiqi [1 ]
机构
[1] Joint Shantou Int Eye Ctr Shantou Univ & Chinese, 69 North Dongxia Rd, Shantou 515041, Guangdong, Peoples R China
来源
ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY | 2021年 / 10卷 / 06期
关键词
adequate silicone oil tamponade; inferior peripheral iridotomy; posterior capsulotomy; retinal detachment; PARS-PLANA VITRECTOMY; OUTCOMES; MANAGEMENT; INJECTION; GLAUCOMA; RISK;
D O I
10.1097/APO.0000000000000436
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the efficacy and safety of adequate silicone oil (SO) tamponade procedure in patients with complicated retinal detachment. Methods: Thirty-one eyes in 31 patients were enrolled in this prospective case series. Adequate SO tamponade was performed by injecting the SO into the vitreous cavity and the entire anterior chamber, followed by posterior capsulotomy and inferior peripheral iridotomy. Preoperative and follow-up data including retinal anatomic reattachment and SO plications and management were collected and analyzed. Results: Twenty-nine eyes presented with complete retinal reattachment after subsequent SO removal with a primary success rate of 93.5%. Seventeen patients (54.8%) had complete anterior chamber SO migration to the vitreous cavity within the first postoperative day. The average time for anterior chamber SO migration was 2.3 +/- 1.8 days. No oil-fluid interface in the vitreous cavity was observed in all the eyes, indicating occurred in 16 (51.6%) eyes and was controllable under medication (n = 16) and anterior chamber paracentesis (n = 1). Two patients develsecondary adequate SO tamponade. At final follow-up, all the eyes attached. ment.
引用
收藏
页码:564 / 571
页数:8
相关论文
共 50 条
  • [41] Anatomical and functional outcomes after heavy silicone oil tamponade in vitreoretinal surgery for complicated retinal detachment - A pilot study
    Tognetto, D
    Minutola, D
    Sanguinetti, G
    Ravalico, G
    OPHTHALMOLOGY, 2005, 112 (09) : 1574 - 1578
  • [42] TEMPORARY SILICONE OIL TAMPONADE IN THE MANAGEMENT OF RETINAL-DETACHMENT WITH PROLIFERATIVE VITREORETINOPATHY
    GONVERS, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (02) : 239 - 245
  • [43] Outcomes of Silicone Oil Tamponade in Pars Plana Vitrectomy for Complex Retinal Detachment
    Parker, Paul
    Acaba-Berrocal, Luis
    Lim, Jennifer
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] 40 years of incomplete silicone oil tamponade after retinal detachment surgery
    Kusserow, C.
    Mueller, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (04) : 298 - 301
  • [45] Treatment of proliferative vitreoretinopathy in rhegmatogenous retinal detachment and silicone oil tamponade.
    Berrod, JP
    Sellier, A
    Rozot, P
    Raspiller, A
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1996, 19 (02): : 97 - 105
  • [46] Macular Edema Following Silicone Oil Tamponade for Retinal Detachment: A Literature Review
    Kontou, Evgenia P.
    Karakosta, Christina
    Kounas, Konstantinos
    Iatropoulos, Ioannis
    Tsinopoulos, Ioannis
    Kozobolis, Vassilios
    Stavrakas, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
  • [47] Peripapillary changes after vitrectomy and silicone oil tamponade for rhegmatogenous retinal detachment
    Jiang, Jian
    Li, Rui
    Zhou, Jin-Xiu
    Li, Rui-Mei
    Wang, Rui-Hua
    Wang, Xia-Ping
    Dou, Ran
    Jia, Ya-Ding
    Li, Shuang-Nong
    Chen, Song
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (12) : 3579 - 3583
  • [48] Heavy Silicone Oil (HSO) as endotamponade in Complicated Retinal Detachment (RD)
    Genovesi-Ebert, F
    Belting, C
    Vento, A
    Di Bartolo, E
    Palla, M
    Rizzo, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U760 - U760
  • [49] RESULTS OF SILICONE OIL REMOVAL IN PATIENTS WITH COMPLICATED FORMS OF RETINAL DETACHMENT
    Matinyan, S. I.
    Vardanyan, A. H.
    Kostanyan, T. H.
    NEW ARMENIAN MEDICAL JOURNAL, 2013, 7 (04): : 57 - 60
  • [50] Mixture of ether and silicone oil for the treatment of inferior complicated retinal detachment
    Romano, Mario R.
    Zenoni, Stefano
    Arpa, Paolo
    Mariotti, Cesare
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (02) : 230 - 235