Application of Dual-Layer Spectral-Detector Computed Tomography Angiography in Identifying Symptomatic Carotid Atherosclerosis: A Prospective Observational Study

被引:2
|
作者
Zhang, Jia [1 ,3 ]
Li, Sijia [1 ,3 ]
Wu, Lei [1 ,3 ]
Wang, Haoyuan [1 ,3 ]
Wang, Chuanying [1 ,3 ]
Zhou, Yinan [5 ]
Sui, Binbin [2 ,3 ]
Zhao, Xingquan [1 ,3 ,4 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Neurol, Beijing 100070, Peoples R China
[2] China Natl Clin Res Ctr Neurol Dis, Tiantan Neuroimaging Ctr Excellence, Beijing 100070, Peoples R China
[3] Capital Med Univ, Beijing Tiantan Hosp, China Natl Clin Res Ctr Neurol Dis, Beijing, Peoples R China
[4] Chinese Acad Med Sci, Res Unit Artificial Intelligence Cerebrovasc Dis, Beijing, Peoples R China
[5] Philips Healthcare, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
carotid plaque; computed tomography angiography; dual-layer spectral-detector dual-energy computed tomography; symptomatic carotid atherosclerosis; ENERGY CT; PLAQUE COMPOSITION; QUANTIFICATION; ASSOCIATION; STENOSIS; FEATURES; STROKE;
D O I
10.1161/JAHA.123.032665
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Dual-layer spectral-detector dual-energy computed tomography angiography (DLCTA) can distinguish components of carotid plaques. Data on identifying symptomatic carotid plaques in patients using DLCTA are not available. Methods and Results In this prospective observational study, patients with carotid plaques were enrolled and received DLCTA. The attenuation for both polyenergetic image and virtual monoenergetic images (40, 70, 100, and 140 keV), as well as Z-effective value, were recorded in the noncalcified regions of plaques. Logistic regression models were used to assess the association between attenuations of DLCTA and the presence of symptomatic carotid plaques. In total, 100 participants (mean +/- SD age, 64.37 +/- 8.31 years; 82.0% were men) were included, and 36% of the cases were identified with the symptomatic group. DLCTA parameters were different between 2 groups (symptomatic versus asymptomatic: computed tomography [CT] 40 keV, 152.63 [interquartile range (IQR), 70.22-259.78] versus 256.78 [IQR, 150.34-408.13]; CT 70 keV, 81.28 [IQR, 50.13-119.33] versus 108.87 [IQR, 77.01-165.88]; slope(40-140 keV), 0.91 [IQR, 0.35-1.87] versus 1.92 [IQR, 0.96-3.00]; Z-effective value, 7.92 [IQR, 7.53-8.46] versus 8.41 [IQR, 7.94-8.92]), whereas no difference was found in conventional polyenergetic images. The risk of symptomatic plaque was lower in the highest tertiles of attenuations in CT 40 keV (adjusted odds ratio [OR], 0.243 [95% CI, 0.078-0.754]), CT 70 keV (adjusted OR, 0.313 [95% CI, 0.104-0.940]), Z-effective values (adjusted OR, 0.138 [95% CI, 0.039-0.490]), and slope40-140 keV (adjusted OR, 0.157 [95% CI, 0.046-0.539]), with all P values and P trends <0.05. The areas under the curve for CT 40 keV, CT 70 keV, slope 40 to 140 keV, and Z-effective values were 0.64, 0.61, 0.64, and 0.63, respectively. Conclusions Parameters of DLCTA might help assist in distinguishing symptomatic carotid plaques. Further studies with a larger sample size may address the overlap and improve the diagnostic accuracy.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison with magnetic resonance imaging
    Liu, Peijun
    Lin, Lu
    Xu, Cheng
    Han, Yechen
    Lin, Xue
    Hou, Yang
    Lu, Xiaomei
    Vembar, Mani
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 310 - 320
  • [42] Radiomics analysis of dual-layer spectral-detector CT-derived iodine maps for predicting tumor deposits in colorectal cancer
    Feng, Fei-Wen
    Jiang, Fei-Yu
    Liu, Yuan-Qing
    Sun, Qi
    Hong, Rong
    Hu, Chun-Hong
    Hu, Su
    EUROPEAN RADIOLOGY, 2025, 35 (01) : 105 - 116
  • [43] Value of dual-layer spectral detector computed tomography in the diagnosis of benign/malignant solid solitary pulmonary nodules and establishment of a prediction model
    Xie, Xiaodong
    Liu, Kaifang
    Luo, Kai
    Xu, Youtao
    Zhang, Lei
    Wang, Meiqin
    Shen, Wenrong
    Zhou, Zhengyang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [44] Dual-layer detector spectral computed tomography quantitative parameters for predicting pathological complete remission after neoadjuvant treatment of breast cancer
    Guo, Shaolan
    Wang, Dandan
    Zhao, Qian
    Bi, Zhao
    Li, Wanhu
    Zhu, Jian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2025, 15 (01) : 149 - 163
  • [45] Differentiation Between Intramural Hematoma and Thrombosed False Lumen in Aortic Dissection Using Latest Spectral Computed Tomography With Dual-Layer Detector
    Funabashi, Nobusada
    Misumi, Kazuo
    CIRCULATION, 2022, 146
  • [46] The ability of virtual noncontrast images to remove intrinsic and external iodine from the thyroid via dual-layer spectral detector computed tomography
    Quan, Yong
    Wu, Ren-Guo
    Li, Liang-Cai
    He, Ya-Qi
    Li, Fang-Yun
    Zhang, Li-Ping
    Deng, Wei-Wei
    Liu, Xiao-Min
    Tang, Bing-Hang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9486 - 9496
  • [47] Computed tomography pulmonary angiograms using a novel dual-layer spectral detector Adjusted window settings are essential for diagnostic image quality
    Iuga, Andra-Iza
    Doerner, Jonas
    Siedek, Florian
    Haneder, Stefan
    Byrtus, Jonathan
    Luetkens, Julian A.
    Maintz, David
    Hickethier, Tilman
    MEDICINE, 2019, 98 (33)
  • [48] Calcium-Suppressed Technique in Dual-layer Detector Computed Tomography to Evaluate Knee Articular Cartilage
    Meng, Qinglin
    Liu, Mengqi
    Deng, Weiwei
    Chen, Ke
    Wang, Botao
    Zhang, Xiaohuan
    Chen, Zhiye
    CURRENT MEDICAL IMAGING, 2021, 17 (03) : 433 - 438
  • [49] Association of liver multi-parameter quantitative metrics determined by dual-layer spectral detector computed tomography (SDCT) with coronary plaque scores
    Wang, Min
    Ma, Yue
    Lan, Yu
    Bai, Ruobing
    Yang, Linlin
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7392 - 7405
  • [50] New Diagnostic Method Using Latest Spectral Computed Tomography With Dual-Layer Detector to Diagnose Pulmonary Thromboembolism and Pulmonary Infarcted Tissue Changes
    Funabashi, Nobusada
    Misumi, Kazuo
    CIRCULATION, 2022, 146