Analytical Method Development and Validation of Perindopril and Amlodipine as Multicomponent Formulation by HPLC Method

被引:1
|
作者
Godse, Vinod D. [1 ,4 ]
Kamble, Priyadarshani R. [2 ]
Patil, Taresh S. [3 ]
机构
[1] Bhupal Nobels Univ, Udaipur 313001, Rajastan, India
[2] Bhupal Nobels Univ, Fac Pharm, Udaipur 313001, Rajastan, India
[3] Core Analyt Pvt Ltd, Management Representat, Maharashtra 422206, India
[4] Bhupal Nobels Univ, Udaipur 313001, Rajastan, India
关键词
Perindopril; Amlodipine; HPLC; ICH guideline; LOD; LOQ; RP-HPLC;
D O I
10.22376/ijlpr.2023.13.3.P1-P9
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The work aims to develop and validate a simple, precise and accurate HPLC method per ICH guidelines. The linearity, specificity, Precision, and accuracy were within limits specified by the ICH guidelines. Hence the proposed system was found to be robust and precise. The objective of this study was to validate the simultaneous assay of Perindopril and Amlodipine by using High-Performance Liquid Chromatography (HPLC). Perindopril and Amlodipine were estimated with C18 Column (2.5 cm x 4.6 mm and five mu m particle size) with a VWD detector. The mobile phase consists of Buffer Solution and Acetonitrile 55:45 v/v with a flow rate of 1 ml/min. The volume injected was 20 mu L. The detection wavelength was 215 nm, respectively. The retention time of Perindopril and Amlodipine was found to be 3.40 min and 4.73 min. The system suitability and all essential validation parameters were meticulously completed. The LOD and LOQ for Perindopril were found to be 2.62 mu g/ml and 7.95 mu g/ml, respectively, and for Amlodipine, 1.06 mu g/ml and 3.22 mu g/ml, respectively. The analytical curve was linear (R2 = 0.999). The system exhibits sufficient accuracy with a relative standard deviation under 2%. The method showed good duplicability and recovery with % RSD less than 2%. The linearity, specificity, Precision, and accuracy were within limits specified by the ICH guidelines. Hence the proposed system was found to be robust and precise. The method has to be such that it takes less time development and the best accurate and complete results have been obtained. Hence the proposed method for simultaneous estimation of Perindopril and Amlodipine by HPLC was found to be robust and precise.
引用
收藏
页码:P1 / P9
页数:9
相关论文
共 50 条
  • [21] ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF ZALEPLON IN PURE AND TABLET FORMULATION
    Rajendran, Rameshpetchi
    Devikasubramaniyan
    Sura, Ramya Sri
    Deepthishalini, M.
    Sirisha, K.
    Janaiah, K.
    Kaveri, K.
    Jyothi, L.
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (04): : 2103 - 2109
  • [22] Development and validation of a new analytical HPLC method for the estimation of carvone in suppositories
    Zaid A.N.
    Abualhasan M.N.
    Jaradat N.
    Marar M.
    Mansoor K.
    Qa’dan F.
    Journal of Pharmaceutical Investigation, 2016, 46 (6) : 557 - 563
  • [23] Analytical Method Development and Validation of Efavirenz by Using RP- HPLC
    Tyagi, Ishu
    Nagarajan, Kandasamy
    Bhardwaj, Snigdha
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL INVESTIGATION, 2025, 15 (01) : 159 - 169
  • [24] Development and Validation of a Simple and Selective Analytical HPLC Method for the Quantification of Oxaliplatin
    Matos, Breno Noronha
    de Oliveira, Paula Martins
    Reis, Thaiene Avila
    Gratieri, Tais
    Cunha-Filho, Marcilio
    Gelfuso, Guilherme Martins
    JOURNAL OF CHEMISTRY, 2015, 2015
  • [25] Development and validation of a new HPLC analytical method for the determination of alprazolam in tablets
    Pérez-Lozano, P
    García-Montoya, E
    Orriols, A
    Miñarro, M
    Ticó, JR
    Suñé-Negre, JM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 979 - 987
  • [26] Analytical method development and validation of pioglitazone hydrochloride by RP-HPLC
    Shaik, Sharmila Begum
    Kiran Joshi, P.
    Usha, M.
    Bindhu, T.
    Ramya, T.
    Journal of Chemical and Pharmaceutical Research, 2014, 6 (06) : 16 - 21
  • [27] Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
    Alquadeib, Bushra Tuwfeeq
    SAUDI PHARMACEUTICAL JOURNAL, 2019, 27 (01) : 66 - 70
  • [28] Development and validation or an analytical method for metformin hydrochloride by HPLC-UV
    Tafzi, N.
    Babiard, M.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2010, 24 : 57 - 57
  • [29] Analytical method validation of oxiracetam using HPLC
    Gon, Kim Yoo
    Seok, Seo Houng
    Hee, Won Chan
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (06): : 587 - 594
  • [30] Analytical Method Development and Validation with Greenness Assessment of HPLC-DAD Method to Determine Methylxanthines
    Portillo-Castillo, Omar J.
    Cobos-Cervantes, Paola
    alvarez-Roman, Rocio
    Perez-Lopez, Luis Alejandro
    Cavazos-Rocha, Norma C.
    Delgado-Montemayor, Cecilia
    Granados-Guzman, Graciela
    ACTA CHIMICA SLOVENICA, 2025, 72 (01) : 180 - 194