Internal dosimetry study of [82Rb]Cl using a long axial field-of-view PET/CT

被引:3
|
作者
Mercolli, Lorenzo [1 ]
Bregenzer, Carola [1 ]
Diemling, Markus [2 ]
Mingels, Clemens [1 ]
Rominger, Axel [1 ]
Sari, Hasan [3 ]
Seibel, Sigrid [1 ]
Sohlberg, Antti [2 ,4 ]
Viscione, Marco [1 ]
Caobelli, Federico [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Nucl Med, Inselspital, Bern, Switzerland
[2] Hermes Med Solut, Stockholm, Sweden
[3] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[4] Paijat Hame Cent Hosp, Dept Clin Physiol & Nucl Med, Lahti, Finland
关键词
Dosimetry; Long axial field-of-view PET/CT; Myocardial perfusion imaging; Rubidium-82; RADIATION-DOSIMETRY; BIODISTRIBUTION;
D O I
10.1007/s00259-024-06660-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
<bold>Purpose: </bold>Long axial field-of-view (LAFOV) positron emission tomography (PET) systems allow to image all major organs with one bed position, which is particularly useful for acquiring whole-body dynamic data using short-lived radioisotopes like Rb-82. <bold>Methods: </bold>We determined the absorbed dose in target organs of three subjects (29, 40, and 57 years old) using two different methods, i.e., MIRD and voxel dosimetry. The subjects were injected with 407.0 to 419.61 MBq of [Rb-82]Cl and were scanned dynamically for 7 min with a LAFOV PET/CT scanner. <bold>Results: </bold>Using the MIRD formalism and voxel dosimetry, the absorbed dose ranged from 1.84 to 2.78 mu Gy/MBq (1.57 to 3.92 mu Gy/MBq for voxel dosimetry) for the heart wall, 2.76 to 5.73 mu Gy/MBq (3.22 to 5.37 mu Gy/MBq for voxel dosimetry) for the kidneys, and 0.94 to 1.88 mu Gy/MBq (0.98 to 1.92 mu Gy/MBq for voxel dosimetry) for the lungs. The total body effective dose lied between 0.50 and 0.76 mu Sv/MBq. <bold>Conclusion: </bold>Our study suggests that the radiation dose associated with [Rb-82]Cl PET/CT can be assessed by means of dynamic LAFOV PET and that it is lower compared to literature values.
引用
收藏
页码:1869 / 1875
页数:7
相关论文
共 50 条
  • [1] Phantom study for 90Y liver radioembolization dosimetry with a long axial field-of-view PET/CT
    Mercolli, Lorenzo
    Zeimpekis, Konstantinos
    Prenosil, George A.
    Sari, Hasan
    Rathke, Hendrik G.
    Rominger, Axel
    Shi, Kunagyu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118
  • [2] CT recon optimisation on Long Axial Field-of-View PET/ CT scanner
    Ferreira, B.
    Edwards, J.
    Holman, B.
    Pritchard, A.
    Shirsavar, H.
    Leite, A.
    Nathan, M.
    Partiphun, A.
    Wilson, T.
    Wagner, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S708 - S709
  • [3] Acceptance Testing of a Long Axial Field-of-View PET/ CT Scanner
    Willson, T.
    Chowdhury, A.
    Davis, N.
    Khan, J.
    Walford, O.
    Natarajan, H.
    McCool, D.
    Holman, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S723 - S723
  • [4] Expert consensus on workflow of PET/CT with long axial field-of-view
    Liu, Guobing
    Gu, Yushen
    Sollini, Martina
    Lazar, Alexandra
    Besson, Florent L.
    Li, Sijin
    Wu, Zhifang
    Nardo, Lorenzo
    Al-Ibraheem, Akram
    Zheng, Jiefu
    Kulkarni, Harshad R.
    Rominger, Axel
    Fan, Wei
    Zhu, Xiaohua
    Zhao, Xinming
    Wu, Hubing
    Liu, Jianjun
    Li, Biao
    Cheng, Zhaoping
    Wang, Ruimin
    Xu, Baixuan
    Agostini, Denis
    Tang, Han
    Tan, Lijie
    Yang, Zhi
    Huo, Li
    Gu, Jianying
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 1038 - 1049
  • [5] Long Axial Field-of-View (LAFOV) PET/CT in Prostate Cancer
    Sachpekidis, Christos
    Dimitrakopoulou-Strauss, Antonia
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (01) : 67 - 75
  • [6] First-time rest-stress dynamic whole-body 82Rb-PET imaging using a long axial field-of-view PET/CT scanner
    Federico Caobelli
    Sigrid Seibel
    Korbinian Krieger
    Carola Bregenzer
    Marco Viscione
    Angela Filipa Silva Mendes
    Hasan Sari
    Lorenzo Mercolli
    Ali Afshar-Oromieh
    Axel Rominger
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 2219 - 2221
  • [7] First-time rest-stress dynamic whole-body 82Rb-PET imaging using a long axial field-of-view PET/CT scanner
    Caobelli, Federico
    Seibel, Sigrid
    Krieger, Korbinian
    Bregenzer, Carola
    Viscione, Marco
    Mendes, Angela Filipa Silva
    Sari, Hasan
    Mercolli, Lorenzo
    Afshar-Oromieh, Ali
    Rominger, Axel
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (07) : 2219 - 2221
  • [8] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Urso, Luca
    Frantellizzi, Viviana
    De Vincentis, Giuseppe
    Schillaci, Orazio
    Filippi, Luca
    Evangelista, Laura
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (04) : 365 - 380
  • [9] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Luca Urso
    Viviana Frantellizzi
    Giuseppe De Vincentis
    Orazio Schillaci
    Luca Filippi
    Laura Evangelista
    Clinical and Translational Imaging, 2023, 11 : 365 - 380
  • [10] -Paediatric Dose Optimization for Long Axial Field-of-View FDG PET/CT
    van der Kaap, D.
    Deuten, M.
    van Snick, P. J. H.
    Noordzij, W.
    Slart, R. H. J. A.
    Brouwers, A. H.
    Glaudemans, A. W. J. M.
    Koopmans, K. P.
    Ivashchenko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S310 - S311