High-Throughput Analyses of Therapeutic Antibodies Using High-Field Asymmetric Waveform Ion Mobility Spectrometry Combined with SampleStream and Intact Protein Mass Spectrometry

被引:2
|
作者
Shi, Rachel Liuqing [3 ]
Dillon, Michael A. [1 ]
Compton, Philip D. [2 ]
Sawyer, William S. [3 ]
Thorup, John R. [3 ]
Kwong, Mandy [3 ]
Chan, Pamela [3 ]
Chiu, Cecilia P. C. [1 ]
Li, Ran [4 ]
Yadav, Rajbharan [4 ]
Lee, Genee Y. [5 ]
Gober, Joshua G. [6 ]
Li, Zhiyu [7 ]
Elsohly, Adel M. [6 ]
Ovacik, Ayse Meric [4 ]
Koerber, James T. [1 ]
Spiess, Christoph [1 ]
Josephs, Jonathan L. [3 ]
Tran, John C. [3 ]
机构
[1] Genentech Inc, Dept Antibody Engn, South San Francisco, CA 94080 USA
[2] Integrated Prot Technol, Evanston, IL 60201 USA
[3] Genentech Inc, Dept Biochem & Cellular Pharmacol, South San Francisco, CA 94080 USA
[4] Genentech Inc, Dept Preclin & Translat Pharmacokinet & Pharmacody, South San Francisco, CA 94080 USA
[5] Genentech Inc, Dept Mol Oncol, South San Francisco, CA 94080 USA
[6] Genentech Inc, Dept Prot Chem, South San Francisco, CA 94080 USA
[7] WuXi AppTec Inc, DMPK Serv Dept, Shanghai 200131, Peoples R China
关键词
BISPECIFIC ANTIBODIES; AFFINITY CAPTURE; IN-VIVO; BIOANALYSIS; DRUG; BIOTRANSFORMATION; QUANTITATION; VALIDATION; DISCOVERY; SERUM;
D O I
10.1021/acs.analchem.3c03158
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Intact protein mass spectrometry (MS) coupled with liquid chromatography was applied to characterize the pharmacokinetics and stability profiles of therapeutic proteins. However, limitations from chromatography, including throughput and carryover, result in challenges with handling large sample numbers. Here, we combined intact protein MS with multiple front-end separations, including affinity capture, SampleStream, and high-field asymmetric waveform ion mobility spectrometry (FAIMS), to perform high-throughput and specific mass measurements of a multivalent antibody with one antigen-binding fragment (Fab) fused to an immunoglobulin G1 (IgG1) antibody. Generic affinity capture ensures the retention of both intact species 1Fab-IgG1 and the tentative degradation product IgG1. Subsequently, the analytes were directly loaded into SampleStream, where each injection occurs within similar to 30 s. By separating ions prior to MS detection, FAIMS further offered improvement in signal-overnoise by similar to 30% for denatured protein MS via employing compensation voltages that were optimized for different antibody species. When enhanced FAIMS transmission of 1Fab-IgG1 was employed, a qualified assay was established for spiked-in serum samples between 0.1 and 25 mu g/mL, resulting in similar to 10% accuracy bias and precision coefficient of variation. Selective FAIMS transmission of IgG1 as the degradation surrogate product enabled more sensitive detection of clipped species for intact 1Fab-IgG1 at 5 mu g/mL in serum, generating an assay to measure 1Fab-IgG1 truncation between 2.5 and 50% with accuracy and precision below 20% bias and coefficient of variation. Our results revealed that the SampleStream-FAIMS-MS platform affords high throughput, selectivity, and sensitivity for characterizing therapeutic antibodies from complex biomatrices qualitatively and quantitatively.
引用
收藏
页码:17263 / 17272
页数:10
相关论文
共 50 条
  • [41] Orbitrap Mass Spectrometry and High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) Enable the in-Depth Analysis of Human Serum Proteoforms
    Kline, Jake T.
    Belford, Michael W.
    Boeser, Cornelia L.
    Huguet, Romain
    Fellers, Ryan T.
    Greer, Joseph B.
    Greer, Sylvester M.
    Horn, David M.
    Durbin, Kenneth R.
    Dunyach, Jean-Jacques
    Ahsan, Nagib
    Fornelli, Luca
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (11) : 3418 - 3426
  • [42] Separation of β2-microglobulin conformers by high-field asymmetric waveform ion mobility spectrometry (FAIMS) coupled to electrospray ionisation mass spectrometry
    Borysik, AJH
    Read, P
    Little, DR
    Bateman, RH
    Radford, SE
    Ashcroft, AE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) : 2229 - 2234
  • [43] Quantitation of morphine and codeine in human urine using high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometric detection
    McCooeye, MA
    Ells, B
    Barnett, DA
    Purves, RW
    Guevremont, R
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (02) : 81 - 87
  • [44] Characterization and Optimization of Multiplexed Quantitative Analyses Using High-Field Asymmetric-Waveform Ion Mobility Mass Spectrometry (vol 91, pg 4010, 2019)
    Schweppe, Devin K.
    Prasad, Satendra
    Belford, Michael W.
    Navarrete-Perea, Jose
    Bailey, Derek J.
    Huguet, Romain
    Jedrychowski, Mark P.
    Rad, Ramin
    McAlister, Graeme
    Abbatiello, Susan E.
    Wouters, Eloy R.
    Zabrouskov, Vlad
    Dunyach, Jean-Jacques
    Paulo, Joao A.
    Gygi, Steven P.
    ANALYTICAL CHEMISTRY, 2020, 92 (06) : 4690 - 4690
  • [45] Decreased Gap Width in a Cylindrical High-Field Asymmetric Waveform Ion Mobility Spectrometry Device Improves Protein Discovery
    Swearingen, Kristian E.
    Winget, Jason M.
    Hoopmann, Michael R.
    Kusebauch, Ulrike
    Moritz, Robert L.
    ANALYTICAL CHEMISTRY, 2015, 87 (24) : 12230 - 12237
  • [46] Separation of Ions from Volatile Organic Compounds Using High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometer
    Li, Hua
    Wang, Xiao-hao
    Tang, Fei
    Yang, Ji
    Ding, Li
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2010, 23 (02) : 125 - 132
  • [47] Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry
    Venne, K
    Bonneil, E
    Eng, K
    Thibault, P
    ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2176 - 2186
  • [48] High-Field Asymmetric Waveform Ion Mobility Spectrometry: Practical Alternative for Cardiac Proteome Sample Processing
    Ai, Lizhuo
    Binek, Aleksandra
    Kreimer, Simion
    Ayres, Matthew
    Stotland, Aleksandr
    Van Eyk, Jennifer E.
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (06) : 2124 - 2130
  • [49] Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications
    Tsai, Chia-Wei
    Tipple, Christopher A.
    Yost, Richard A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (07) : 552 - 560
  • [50] Peak deconvolution in high-field asymmetric waveform ion mobility spectrometry (FAIMS) to characterize macromolecular conformations
    Robinson, Errol W.
    Sellon, Rachel E.
    Williams, Evan R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) : 87 - 95