Off-Axis Loading Fixture for Spine Biomechanics: Combined Compression and Bending

被引:1
|
作者
Moore, Axel C. [1 ]
Holder, Dione A. [2 ]
Elliott, Dawn M. [2 ]
机构
[1] Univ Delaware, Dept Biomed Engn, STAR Hlth Sci Complex, Room 109 540 S Coll Ave, Newark, DE 19713 USA
[2] Univ Delaware, Dept Biomed Engn, Newark, DE 19713 USA
关键词
biomechanics; multi-axis mechanics; functional spinal unit; spine biomechanics; intervertebral disc; MOTION SEGMENT STIFFNESS; LUMBAR SPINE; INTERVERTEBRAL DISC; INTRADISCAL PRESSURE; ROTATION; FREEDOM; DEGENERATION; FLEXIBILITY;
D O I
10.1115/1.4062780
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The spine is a multi-tissue musculoskeletal system that supports large multi-axial loads and motions during physiological activities. The healthy and pathological biomechanical function of the spine and its subtissues are generally studied using cadaveric specimens that often require multi-axis biomechanical test systems to mimic the complex loading environment of the spine. Unfortunately, an off-the-shelf device can easily exceed 200,000 USD, while a custom device requires extensive time and experience in mechatronics. Our goal was to develop a cost-appropriate compression and bending (flexion-extension and lateral bending) spine testing system that requires little time and minimal technical knowledge. Our solution was an off-axis loading fixture (OLaF) that mounts to an existing uni-axial test frame and requires no additional actuators. OLaF requires little machining, with most components purchased off-the-shelf, and costs less than 10,000 USD. The only external transducer required is a six-axis load cell. Furthermore, OLaF is controlled using the existing uni-axial test frame's software, while the load data is collected using the software included with the six-axis load cell. Here we provide the design rationale for how OLaF develops primary motions and loads and minimizes off-axis secondary constraints, verify the primary kinematics using motion capture, and demonstrate that the system is capable of applying physiologically relevant, noninjurious, axial compression and bending. While OLaF is limited to compression and bending studies it produces repeatable physiologically relevant biomechanics, with high quality data, and minimal startup costs.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [41] Effect of Anisotropy and Off-Axis Loading on Fatigue Property of 1050 Wheel Steel
    Zhang Qingsong
    Zhu Zhenyu
    Gao Jiewei
    Dai Guangze
    Xu Lei
    Feng Jian
    ACTA METALLURGICA SINICA, 2017, 53 (03) : 307 - 315
  • [42] INTERNAL MATERIAL DAMPING OF POLYMER MATRIX COMPOSITES UNDER OFF-AXIS LOADING
    SUN, CT
    GIBSON, RF
    CHATURVEDI, SK
    JOURNAL OF MATERIALS SCIENCE, 1985, 20 (07) : 2575 - 2585
  • [44] ELASTIC ANALYSIS OF WOVEN FABRIC LAMINATES .1. OFF-AXIS LOADING
    SHEMBEKAR, PS
    NAIK, NK
    JOURNAL OF COMPOSITES TECHNOLOGY & RESEARCH, 1993, 15 (01): : 23 - 33
  • [45] Fatigue of Woven Composite Laminates in Off-Axis Loading I. The Mastercurves
    V. Tamuzs
    K. Dzelzitis
    K. Reifsnider
    Applied Composite Materials, 2004, 11 : 259 - 279
  • [46] Nonlinear Mechanical Response of CFRP Laminates under Off-Axis Tensile Loading
    Ogihara, Shinji
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2010, 17 (02): : 133 - 141
  • [47] Fatigue of woven composite laminates in off-axis loading I. The mastercurves
    Tamuzs, V
    Dzelzitis, K
    Reifsnider, K
    APPLIED COMPOSITE MATERIALS, 2004, 11 (05) : 259 - 279
  • [48] Trabecular bone reinforces cortical bone capability to withstand off-axis loading
    Barak, Meir M.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2018, 165 : 18 - 18
  • [49] Off-axis image plane hologram compression in holographic tomography - metrological assessment
    Muhamad, R. K.
    Stcpie, P.
    Kujawinska, M.
    Schelkens, P.
    OPTICS EXPRESS, 2022, 30 (03) : 4261 - 4273
  • [50] Influence of off-axis ply orientation on the axial compression behaviour of CFRP tubes
    Tao, Jie
    Li, Feng
    Zhao, Qilin
    Zhang, Dongdong
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2017, 36 (06) : 399 - 413