High-precision measurement of europium isotopic composition of geological reference materials by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)

被引:5
|
作者
Nicol, Lukas [1 ]
Garcon, Marion [1 ]
Boyet, Maud [1 ]
Gannoun, Abdelmouhcine [1 ]
机构
[1] Univ Clermont Auvergne, CNRS, OPGC, Lab Magmas & Volcans,IRD, F-63000 Clermont Ferrand, France
基金
欧洲研究理事会;
关键词
ROCK DISSOLUTION; EXCHANGE SYSTEM; GADOLINIUM; GD; SM; SAMARIUM; RATIO; BIAS;
D O I
10.1039/d3ja00042g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To date only few analyses of europium (Eu) isotopic composition of terrestrial and extraterrestrial samples have been reported in the literature. This isotopic systematic remains largely understudied and it is still unknown whether the Eu isotopic composition of the Earth's major reservoirs show measurable variations. Here we present a comprehensive chemical protocol to separate Eu from different sample matrices and a method for measuring high-precision Eu isotopic composition by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). We show that the chemical separation of Eu by ion chromatography may induce measurable isotopic fractionation and that careful attention must be taken to limit analytical artefacts. As Eu has only two stable isotopes, we investigated different methods to correct as best as possible for instrumental mass bias. We found that doping the samples with samarium (Sm), a close neighbor of Eu, provided the best precision and trueness. Based on complete duplicate analyses, we evaluated the repeatability standard deviation (2SD) of the whole procedure at about 50 ppm on the Eu-151/Eu-153 ratio (i.e. 0.5 epsilon unit), which is two to four times better than previously published procedures. All igneous and sedimentary reference materials analyzed in this study have Eu isotopic compositions similar to the reference standard NIST 3117a within uncertainties (i.e. epsilon(Eu) = 0 +/- 0.5).
引用
收藏
页码:1261 / 1274
页数:14
相关论文
共 50 条
  • [31] High-precision measurement of Ag isotopes for silicate rocks by MC-ICP-MS
    Fang, Yuan
    Wen, Qiu-Yu
    Xiao, Zi-Cong
    Yu, Hui-Min
    Huang, Fang
    Journal of Analytical Atomic Spectrometry, 1600, 39 (07): : 1750 - 1758
  • [32] Refining Boron Isotopic Measurements of Silicate Samples by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS)
    Paul, Andre N.
    Stewart, Joseph A.
    Agostini, Samuele
    Kirstein, Linda A.
    De Hoog, Jan C. M.
    Savov, Ivan P.
    Walowski, Kristina
    Rae, James W. B.
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (01) : 91 - 108
  • [33] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (09) : 1560 - 1567
  • [34] High-precision magnesium isotope analysis of geological and environmental reference materials by multiple-collector inductively coupled plasma mass spectrometry
    Gao, Ting
    Ke, Shan
    Li, Ruiying
    Meng, Xu'nan
    He, Yongsheng
    Liu, Chengshuai
    Wang, Yang
    Li, Zijian
    Zhu, Jian-Ming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (08) : 767 - 777
  • [35] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    Journal of Analytical Atomic Spectrometry, 2012, 27 (09): : 1560 - 1567
  • [36] Determination of indium isotopic ratios of geostandards with different matrices by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Zhu, Chuanwei
    Wu, Yunzhu
    Liu, Zerui
    Zhou, Meifu
    Yang, Guangshu
    Zhang, Yuxu
    Wen, Hanjie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1867 - 1873
  • [37] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [38] High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket
    Li, Ming
    Lei, Yv
    Feng, Lanping
    Wang, Zaicong
    Belshaw, Nick S.
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chen, Haihong
    Chai, Xinna
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1707 - 1719
  • [39] A two-stage column protocol for the separation of Cu from geological materials and high-precision Cu isotopic analysis on a MC-ICP-MS
    Li, Jie
    Zhong, Qiao-Hui
    Zhang, Le
    Yu, Hong-Xia
    Wang, Zhao-Yang
    Bao, Hou-Yin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (04) : 849 - 860
  • [40] A Rapid and Simple Method for Lithium Purification and Isotopic Analysis of Geological Reference Materials by MC-ICP-MS
    Zhu, Guanhong
    Ma, Jinlong
    Wei, Gangjian
    Zhang, Le
    FRONTIERS IN CHEMISTRY, 2020, 8