Reproducibility of non-contrast enhanced multi breath-hold ultrashort echo time functional lung MRI

被引:0
|
作者
Metz, C. [1 ,3 ,4 ,5 ]
Weng, A. M. [1 ]
Heidenreich, J. F. [1 ]
Slawig, A. [1 ]
Benkert, T. [2 ]
Koestler, H. [1 ]
Veldhoen, S. [1 ,3 ,4 ,5 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Wurzburg, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Charite, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Free Univ Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Humboldt Univ, Pediat Radiol, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词
Functional lung MRI; Ultrashort echo time; UTE; Stack-of-spirals; Fractional ventilation; Reproducibility; VENTILATION ASSESSMENT; FOURIER DECOMPOSITION; TIDAL VOLUME; RECONSTRUCTION; PERFUSION; STANDARD;
D O I
10.1016/j.mri.2023.01.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the intraindividual reproducibility of functional lung imaging using non-contrast enhanced multi breath-hold 3D-UTE MRI.Methods: Ten healthy volunteers underwent non-contrast enhanced 3D-UTE MRI at three time points for same -day and different-day measurements employing a stack-of-spirals trajectory at 3 T. At each time point, inspi-ratory and expiratory breathing states were acquired for tidal and deep breathing, each within a single breath -hold. For functional image analysis, fractional ventilation (FV) was calculated pixelwise after image registration from the MR signal change. To decouple FV from breathing depth, the individual lung volume was used for volume adjustment (rFV). Reproducibility evaluation was performed in eight lung segments. Statistical analyses included two way mixed intraclass correlation (ICC), sign-test, Friedman-test and modified Bland-Altman analyses.Results: FV from tidal breathing showed an ICC of 0.81, a bias of 1.3% and an interval of confidence (CI) ranging from-67.1 to 69.6%. FV from deep breathing was higher reproducible with an ICC of 0.92 (bias,-0.2%; CI,-34.2 to 33.7%). Following volume adjustment, reproducibility of rFV for tidal breathing improved (ICC, 0,86; bias, 2.0%; CI,-34.3 to 38.3%), whereas it did not bear significant benefits for deep breathing (ICC, 0.89; bias, 2.8%; CI,-24.9 to 30.5%). Reproducibility was independent from the examination day. Conclusion: Non-contrast-enhanced multi breath-hold 3D-UTE MRI allows for highly reproducible ventilation imaging.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [1] Functional MRI of the Lungs Using Single Breath-Hold and Self-Navigated Ultrashort Echo Time Sequences
    Heidenreich, Julius F.
    Veldhoen, Simon
    Metz, Corona
    Pereira, Lenon Mendes
    Benkert, Thomas
    Pfeuffer, Josef
    Bley, Thorsten A.
    Kostler, Herbert
    Weng, Andreas M.
    [J]. RADIOLOGY-CARDIOTHORACIC IMAGING, 2020, 2 (03):
  • [2] Evaluation of optimized breath-hold and free-breathing 3D ultrashort echo time contrast agent-free MRI of the human lung
    Gai, Neville D.
    Malayeri, Ashkan
    Agarwal, Harsh
    Evers, Robert
    Bluemke, David
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (05) : 1230 - 1238
  • [3] Applying Compressed Sensing Volumetric Interpolated Breath-Hold Examination and Spiral Ultrashort Echo Time Sequences for Lung Nodule Detection in MRI
    Huang, Yu-Sen
    Niisato, Emi
    Su, Mao-Yuan Marine
    Benkert, Thomas
    Chien, Ning
    Chiang, Pin-Yi
    Lee, Wen-Jeng
    Chen, Jin-Shing
    Chang, Yeun-Chung
    [J]. DIAGNOSTICS, 2022, 12 (01)
  • [4] Echo-train STIR MRI of the liver: Comparison of breath-hold and non-breath-hold imaging strategies
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01): : 87 - 92
  • [5] Highly accelerated single breath-hold non-contrast thoracic MRA: evaluation in a clinical population
    Ruth P Lim
    Priscilla A Winchester
    Mary T Bruno
    Jian Xu
    Pippa Storey
    Kelly Anne McGorty
    Daniel K Sodickson
    Monvadi B Srichai
    [J]. Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [6] INTER-STUDY REPRODUCIBILITY OF STRAIN MEASURMENTS BY CARDIAC MRI: A COMPARISON OF FEATURE TRACKING, SINGLE BREATH-HOLD TAGGING AND MULTI BREATH-HOLD TAGGING
    Singh, A.
    Steadman, C. D.
    Khan, J. N.
    Nazir, S. A.
    McCann, G. P.
    [J]. HEART, 2013, 99
  • [7] Reproducibility of functional lung parameters derived from free-breathing non-contrast-enhanced 2D ultrashort echo-time
    Yang, Bingjie
    Metze, Patrick
    Balasch, Anke
    Stumpf, Kilian
    Beer, Meinrad
    Rottbauer, Wolfgang
    Rasche, Volker
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (10) : 4720 - +
  • [8] Audiovisual Biofeedback Improves Breath-Hold Lung Tumor Position Reproducibility Measured with 4D MRI
    Lee, D.
    Greer, P.
    Lapuz, C.
    Ludbrook, J.
    Pollock, S.
    Kim, T.
    Keall, P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3320 - 3320
  • [9] Real-Time Verification and Quantification of Breath-Hold Reproducibility During Treatment for Liver and Lung SBRT
    Antolak, A.
    Woody, N.
    Stephans, K.
    Xia, P.
    Guo, B.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E655 - E655
  • [10] Multi-average high-acceleration modified volumetric interpolated breath-hold examination (VIBE) for free-breathing multiphase contrast-enhanced liver MRI: a comparative study with breath-hold VIBE
    Chang, Ming-Hwa
    Wang, Wei-Teng
    Teng, Hui-Chung
    Wang, Shu-Chin
    Cheng, Hsiu-Wen
    Huang, Jer-Shyung
    Wu, Ming-Ting
    [J]. ACTA RADIOLOGICA, 2024, 65 (07) : 735 - 743