Variability in Cardiopulmonary Exercise Testing Biologic Controls

被引:1
|
作者
DeCato, Thomas W. [1 ,2 ,3 ,7 ]
Haverkamp, Hans C. [4 ]
Gooding, Thomas [4 ]
Collingridge, Dave S. [5 ]
Hegewald, Matthew J. [5 ,6 ]
机构
[1] Harbor UCLA Med Ctr, Div Resp & Crit Care Physiol & Med, Torrance, CA USA
[2] Harbor UCLA Med Ctr, Lundquist Inst Biomed Innovat, Torrance, CA USA
[3] Washington State Univ, Elson S Floyd Coll Med, Dept Med Educ & Clin Sci, Spokane, WA USA
[4] Washington State Univ, Elson S Floyd Coll Med, Dept Nutr & Exercise Physiol, Spokane, WA USA
[5] Intermt Med Ctr, Pulm & Crit Care Med, Murray, UT USA
[6] Univ Utah, Div Resp Crit Care & Occupat Pulm Med, Salt Lake City, UT USA
[7] Harbor UCLA Med Ctr, 1000 W Carson St,CDCRC Box 402, Torrance, CA 90509 USA
关键词
cardiopulmonary exercise testing; CPET; biocontrol; quality control; REFERENCE VALUES; QUALITY-CONTROL;
D O I
10.4187/respcare.10022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Cardiopulmonary exercise testing is an increasingly common test and is consid-ered the accepted standard for assessing exercise capacity. Quantifying variability is important to assess the instrument for quality control purposes. Though guidelines recommend biologic control testing, there are minimal data on how to do it. We sought to describe variability for oxygen con-sumption (VO2), carbon dioxide production (VCO2), and minute ventilation (VE) at various work rates under steady-state conditions in multiple subjects over a 1-y period to provide a practical approach to assess and perform biologic control testing. METHODS: We performed a single-center, prospec-tive study with 4 healthy subjects, 2 men and 2 women. Subjects performed constant work rate exer-cise tests for 6 min each at 25-100 W intervals on a computer-controlled cycle ergometer. Data were averaged over the last 120 s at each work rate to reflect stepwise steady-state conditions. Descriptive statistics, including the mean, median, range, SD, and coefficient of variation (CoV) are reported for each individual across the 4 work rates and all repetitions. As these data were normative, z-scores were utilized, and a value greater than +/- 1.96 z-scores was used to define significant test variability. RESULTS: Subjects performed 16-39 biocontrol studies over 1-y. The mean CoV for all subjects in VO2 was 6.59%, VCO2 was 6.41%, and VE was 6.32%. The +/- 1.96 z-scores corresponded to a 9.4- 18.1% change in VO2 , a 9.6-18.1% change in VCO2 , and a 9-21.5% change in VE across the 4 workloads. CONCLUSIONS: We report long-term variability for steady-state measurement of VO2 , VCO2 , and VE obtained during biocontrol testing. Utilizing +/- 1.96 z-scores allows one to determine if a result exceeds expected variability, which may warrant investigation of the instrument.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [31] Cardiopulmonary exercise testing in thalassemia
    John-Paul Carpenter
    Dudley J. Pennell
    The International Journal of Cardiovascular Imaging, 2009, 25 : 785 - 788
  • [32] Cardiopulmonary Exercise Testing in Research
    Miller, Alexandria
    Vanderpool, Rebecca R.
    HEART FAILURE CLINICS, 2025, 21 (01) : 111 - 117
  • [33] Exercise Tolerance During Cardiopulmonary Exercise Testing
    Midgley, Adrian
    Clough, Peter
    Earle, Fiona
    Keith, Earle
    Siegler, Jason
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 612 - 613
  • [34] The cardiopulmonary exercise testing vs standard exercise testing in cardiac rehabilitation
    Stuto, A.
    Cosentino, G.
    Ambu, A.
    Bottaro, G.
    Campanelli, A.
    Corpaci, M.
    Raineri, F.
    D'aquila, F.
    Armaro, B.
    Basile, G.
    EUROPEAN HEART JOURNAL, 2008, 29 : 15 - 15
  • [35] Cardiopulmonary exercise testing and body composition
    Karlsson, Per
    Lind, Lars
    Michaelsson, Karl
    Malinovschi, Andrei
    ERJ OPEN RESEARCH, 2024, 10 (03)
  • [36] Cardiopulmonary exercise testing and its application
    Albouaini, K.
    Egred, M.
    Alahmar, A.
    Wright, D. J.
    HEART, 2007, 93 (10) : 1285 - 1292
  • [37] Guidance to the Interpretation of Cardiopulmonary Exercise Testing
    Glaab, T.
    Schmidt, O.
    Fritsch, J.
    PNEUMOLOGIE, 2020, 74 (02): : 88 - 102
  • [38] Cardiopulmonary Exercise Testing in Heart Failure
    Myers, Jonathan
    Arena, Ross
    Cahalin, Lawarence P.
    Labate, Valentina
    Guazzi, Marco
    CURRENT PROBLEMS IN CARDIOLOGY, 2015, 40 (08) : 322 - 372
  • [39] CONCEPTS AND APPLICATIONS OF CARDIOPULMONARY EXERCISE TESTING
    WEBER, KT
    JANICKI, JS
    MCELROY, PA
    REDDY, HK
    CHEST, 1988, 93 (04) : 843 - 847
  • [40] Understanding the basics of cardiopulmonary exercise testing
    Milani, Richard V.
    Lavie, Carl J.
    Mehra, Mandeep R.
    Ventura, Hector O.
    MAYO CLINIC PROCEEDINGS, 2006, 81 (12) : 1603 - 1611