Brine-water experimental study on the propagation of stratified smoke flow in tunnel fires under subcritical longitudinal ventilation

被引:7
|
作者
Du, Tao [1 ]
Yu, Haoyue [2 ]
Lu, Xianyuan [2 ]
Yang, Dong [2 ]
机构
[1] Changan Univ, Sch Civil Engn, Xian 710061, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
Subcritical ventilation; Tunnel fire; Brine-water experiments; Propagation velocity; Density distribution; Backlayering flow thickness; ENTRAINMENT; VELOCITY; TEMPERATURE; FLUID;
D O I
10.1016/j.tust.2023.105176
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the early stage of tunnel fires, longitudinal ventilation velocity is often smaller than the critical velocity to preserve the smoke stratification and therefore facilitate the evacuation. A series of brine-water experiments are conducted to investigate the unsymmetrical propagation of the stratified smoke flow under subcritical ventilation. A light attenuation technique is used to measure the distribution of the reduced gravity in the tunnel. The ventilation velocity V and the source buoyancy flux per unit width B-0 are two dominant parameters for the flow. The reduced gravities at both sides of the source are quantitatively compared, and then a model is proposed to estimate the reduced gravities under different B-0 and V. In terms of the propagation velocity, two flow regimes are observed. When V/B-0(1/3) is smaller than 0.56, both the propagation velocity of the downstream smoke front, ud, and that of the backlayering smoke front, ub, are independent of time; moreover, ud is smaller than the propagation velocity of the smoke following the downstream smoke front. However, when V/B-0(1/3) is larger than 0.56, ud is still independent of time, but ub decreases with time; furthermore, ud is approximately equal to the propagation velocity of the smoke following the front. Prediction models regarding the propagation velocities at both sides of the fire are established. As the backlayering flow advances forward, its thickness approximately linearly decreases. The maximum thickness of the backlayering flow is correlated with V/B-0(1/3). The study might be useful for determining the ventilation and evacuation strategies in tunnel fires.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Smoke control and temperature distribution of tunnel fires under longitudinal ventilation combined with shaft exhaust
    Zhang, Xinyue
    Ma, Weiling
    Tao, Liangliang
    Zeng, Yanhua
    Wen, Yumin
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 65
  • [22] Experimental study on smoke movement characteristics and control in branched tunnel fire under longitudinal ventilation
    Lei, Peng
    Chen, Changkun
    Zhao, Dongyue
    Journal of Railway Science and Engineering, 2022, 19 (07) : 2117 - 2124
  • [23] A Study of the Critical Velocity of Smoke Bifurcation Flow in Tunnel with Longitudinal Ventilation
    Zhong, Wei
    Duanmu, Weike
    Wang, Tao
    Liang, Tianshui
    FIRE TECHNOLOGY, 2017, 53 (02) : 873 - 891
  • [24] A Study of the Critical Velocity of Smoke Bifurcation Flow in Tunnel with Longitudinal Ventilation
    Wei Zhong
    Weike Duanmu
    Tao Wang
    Tianshui Liang
    Fire Technology, 2017, 53 : 873 - 891
  • [25] Investigation on smoke propagation behavior and smoke back-layering length of fires in an inclined tunnel under natural ventilation
    Wang, Bowen
    Peng, Wei
    Zhong, Wei
    Liang, Tianshui
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 150
  • [26] Experimental study on effect of longitudinal ventilation velocity on burning rate in tunnel fires
    Yang, SS
    Rho, JS
    Ryou, HS
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 913 - 920
  • [27] Experimental study on the effects of branch tunnel ventilation on the smoke movement and temperature characteristics in bifurcated tunnel fires
    Jiao, Weibing
    Chen, Changkun
    Lei, Peng
    Zhang, Yulun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 144
  • [28] Experimental Investigation on Fire Smoke Temperature under Forced Ventilation Conditions in a Bifurcated Tunnel with Fires Situated in a Branch Tunnel
    Guo, Hanwen
    Yang, Zhengyuan
    Zhang, Peiyao
    Gao, Yunji
    Zhang, Yuchun
    FIRE-SWITZERLAND, 2023, 6 (12):
  • [29] An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires
    Lee, SR
    Ryou, HS
    JOURNAL OF FIRE SCIENCES, 2005, 23 (02) : 119 - 138
  • [30] Theoretical and numerical study on smoke descent during tunnel fires under natural ventilation condition
    Zhao, Shengzhong
    Yang, Haoran
    Li, Ying Zhen
    Ingason, Haukur
    Liu, Fang
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 142