Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm

被引:4
|
作者
Rahman, Md. Mahmudur [1 ,2 ]
Gan, Kok Beng [3 ]
Abd Aziz, Noor Azah [4 ]
Huong, Audrey [5 ]
You, Huay Woon [6 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Malaysia
[2] Daffodil Int Univ, Dept Elect & Elect Engn, Dhaka 1216, Bangladesh
[3] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Med Engn & Syst Res Grp, Bangi 43600, Malaysia
[4] Univ Kebangsaan Malaysia, Fac Med, Dept Family Med, Med Ctr, Kuala Lumpur 56000, Malaysia
[5] Univ Tun Hussein Onn Malaysia, Dept Elect Engn, Parit Raja 86400, Malaysia
[6] Univ Kebangsaan Malaysia, Pusat GENIUSPintar Negara, Bangi 43600, Malaysia
关键词
inertial measurement unit; accelerometer; gyroscope; magnetometer; electro-goniometer; joint angle; rigid body; sensor fusion; Madgwick filter; Kalman filter; COMPLEMENTARY FILTER; OPTIMIZATION; GYROSCOPES;
D O I
10.3390/math11040970
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
In physical therapy, exercises improve range of motion, muscle strength, and flexibility, where motion-tracking devices record motion data during exercises to improve treatment outcomes. Cameras and inertial measurement units (IMUs) are the basis of these devices. However, issues such as occlusion, privacy, and illumination can restrict vision-based systems. In these circumstances, IMUs may be employed to focus on a patient's progress quantitatively during their rehabilitation. In this study, a 3D rigid body that can substitute a human arm was developed, and a two-stage algorithm was designed, implemented, and validated to estimate the elbow joint angle of that rigid body using three IMUs and incorporating the Madgwick filter to fuse multiple sensor data. Two electro-goniometers (EGs) were linked to the rigid body to verify the accuracy of the joint angle measuring algorithm. Additionally, the algorithm's stability was confirmed even in the presence of external acceleration. Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46 degrees. Using the IMU manufacturer's (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97 degrees. For the fourth trial, joint angles were also calculated with external acceleration, and the RMSE was 0.996 degrees. In all cases, the joint angles were within therapeutic limits.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Self-calibration of wearable upper limb Cable- driven exoskeleton
    Ji, Yuhan
    Chen, Weihai
    Zhang, Jianbin
    Fang, Zaojun
    Chen, Wenjie
    PROCEEDINGS OF THE 15TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2020), 2020, : 1520 - 1525
  • [22] Upper Limb Analysis Using Wearable Sensors For Cricket
    Gawsalyan, S.
    Janarthanan, T. S.
    Thiruthanikan, N.
    Shahintha, R.
    Silva, Pujitha
    PROCEEDINGS OF THE 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES (ICECCT), 2017,
  • [23] IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement—a proof of concept
    Mahdi Zabat
    Amina Ababou
    Noureddine Ababou
    Raphaël Dumas
    Medical & Biological Engineering & Computing, 2019, 57 : 2449 - 2460
  • [24] A Preliminary Research into Joint Angle Prediction of the Upper Limb using Surface Electromyogram for a Cooperative Machine
    Kwon, Suncheol
    Kim, Jung
    2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 2127 - 2130
  • [25] EMG-based Continuous Prediction of the Upper Limb Elbow Joint Angle Using GRNN
    Guo, Shuxiang
    Yang, Ziyi
    Liu, Yi
    2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 2168 - 2173
  • [26] Effect of velocity and acceleration in joint angle estimation for an EMG-Based upper-limb exoskeleton control
    Tang, Zhichuan
    Yu, Hongnian
    Yang, Hongchun
    Zhang, Lekai
    Zhang, Lufang
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 141
  • [27] Continuous estimation of upper limb joint angle from sEMG based on multiple decomposition feature and BiLSTM network
    Wen, Liqun
    Xu, Jiacan
    Li, Donglin
    Pei, Xinglong
    Wang, Jianhui
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 80
  • [28] Enhancing Automatic Inertial Sensor Calibration Algorithm for Accurate Joint Angle Estimation in High Flexion Postures
    Laudanski, Annemarie F.
    Kuederle, Arne
    Kluge, Felix
    Eskofier, Bjoern
    Acker, Stacey M.
    IEEE SENSORS JOURNAL, 2024, 24 (16) : 26542 - 26551
  • [29] Research on Joint Motion Control of Soft Wearable Upper Limb Rehabilitation Robots
    Zhai Y.
    Ma X.
    Chen D.
    Lei J.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2021, 49 (06): : 19 - 27
  • [30] Kinect-Based Method for Upper Limb Joint Angle Measurement
    Guo, Fangqiang
    Lu, Liang
    Zhu, Shiwei
    Sun, Mingxu
    Shen, Tao
    Zhu, Yiming
    Wang, Wenyuan
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND NETWORKS, VOL II, CENET 2023, 2024, 1126 : 544 - 552