Effectiveness of robust optimization against geometric uncertainties in TomoHelical planning for prostate cancer

被引:4
|
作者
Yagihashi, Takayuki [1 ,2 ]
Inoue, Kazumasa [2 ]
Nagata, Hironori [1 ]
Yamanaka, Masashi [1 ,3 ]
Yamano, Akihiro [1 ]
Suzuki, Shunsuke [1 ,4 ]
Yamakabe, Wataru [1 ]
Sato, Naoki [1 ]
Omura, Motoko [5 ]
Inoue, Tatsuya [1 ,6 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Med Phys, Kamakura, Kanagawa, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Human Hlth Sci, Arakawa Ku, Tokyo, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Med Phys Lab, Suita, Osaka, Japan
[4] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto, Japan
[5] Shonan Kamakura Gen Hosp, Dept Radiat Oncol, Kamakura, Kanagawa, Japan
[6] Juntendo Univ, Dept Radiat Oncol, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
来源
关键词
helical tomotherapy; intensity-modulated radiotherapy; localized prostate cancer; minimax robust optimization; MODULATED ARC THERAPY; HELICAL TOMOTHERAPY; PROTON THERAPY; RADIATION-THERAPY; RADIOTHERAPY; HEAD; RANGE; SETUP; IMRT; VMAT;
D O I
10.1002/acm2.13881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundGeometrical uncertainties in patients can severely affect the quality of radiotherapy. PurposeWe evaluated the dosimetric efficacy of robust optimization for helical intensity-modulated radiotherapy (IMRT) planning in the presence of patient setup uncertainty and anatomical changes. MethodsTwo helical IMRT plans for 10 patients with localized prostate cancer were created using either minimax robust optimization (robust plan) or a conventional planning target volume (PTV) margin approach (PTV plan). Plan robustness was evaluated by creating perturbed dose plans with setup uncertainty from isocenter shifts and anatomical changes due to organ variation. The magnitudes of the geometrical uncertainties were based on the patient setup uncertainty considered during robust optimization, which was identical to the PTV margin. The homogeneity index, and target coverage (TC, defined as the V100% of the clinical target volume), and organs at risk (OAR; rectum and bladder) doses were analyzed for all nominal and perturbed plans. A statistical t-test was performed to evaluate the differences between the robust and PTV plans. ResultsComparison of the nominal plans showed that the robust plans had lower OAR doses and a worse homogeneity index and TC than the PTV plans. The evaluations of robustness that considered setup errors more than the PTV margin demonstrated that the worst-case perturbed scenarios for robust plans had significantly higher TC while maintaining lower OAR doses. However, when anatomical changes were considered, improvement in TC from robust optimization was not observed in the worst-case perturbed plans. ConclusionsFor helical IMRT planning in localized prostate cancer, robust optimization provides benefits over PTV margin-based planning, including better OAR sparing, and increased robustness against systematic patient-setup errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Robust treatment planning for intensity modulated radiotherapy of prostate cancer based on coverage probabilities
    Baum, C
    Alber, M
    Birkner, M
    Nüsslin, F
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 (01) : 27 - 35
  • [42] Planning, computer optimization, and dosimetric verification of a segmented irradiation technique for prostate cancer
    Damen, EMF
    Brugmans, MJP
    van der Horst, A
    Bos, L
    Lebesque, JV
    Mijnheer, BJ
    McShan, DL
    Fraass, BA
    Kessler, ML
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (04): : 1183 - 1195
  • [43] Planning and dosimetric evaluation of multi criteria optimization (MCO) for VMAT prostate cancer
    Mazouni, Z.
    Matzinger, O.
    Lacombe, C.
    Pachoud, M.
    Gandhour, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (01) : 96 - 96
  • [44] A distributionally robust optimization model for building-integrated photovoltaic system expansion planning under demand and irradiance uncertainties
    Wu, Zhuochun
    Kang, Jidong
    Mosteiro-Romero, Martin
    Bartolini, Andrea
    Ng, Tsan Sheng
    Su, Bin
    APPLIED ENERGY, 2024, 372
  • [45] Robust Optimization for Microgrid Defense Resource Planning and Allocation Against Multi-Period Attacks
    Lei, Hongtao
    Huang, Shengjun
    Liu, Yajie
    Zhang, Tao
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (05) : 5841 - 5850
  • [46] Validation of the dosimetric and geometric accuracy of MR-only treatment planning solution for prostate cancer radiotherapy
    Posiewnik, Michal
    Piotrowski, Tomasz
    WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY, 2021, 25 (04): : 241 - 245
  • [47] Dosimetric implications of approximating setup uncertainties with Gaussian distributions in Monte Carlo based prostate cancer treatment planning
    Chetty, I
    Lam, K
    Balter, J
    Ten Haken, R
    McShan, D
    Sandler, H
    Litzenberg, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S77 - S77
  • [48] Robust optimization for IMPT of pencil-beam scanning proton therapy for prostate cancer
    Brouwer, C. L.
    Matysiak, W. P.
    Klinker, P.
    Spijkerman-Bergsma, M.
    Hammer, C.
    Van den Bergh, A. C. M.
    Langendijk, J. A.
    Scandurra, D.
    Korevaar, E. W.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S835 - S836
  • [49] Robust treatment planning in whole pelvis pencil beam scanning proton therapy for prostate cancer
    Butala, Anish A.
    Ingram, W. Scott
    O'Reilly, Shannon E.
    Hartl, Brett
    Kassaee, Ali
    Deville, Curtiland
    Vapiwala, Neha
    MEDICAL DOSIMETRY, 2020, 45 (04) : 334 - 338
  • [50] Synergistic action of lactoferrin in enhancing the safety and effectiveness of docetaxel treatment against prostate cancer
    Muj, Chukhu
    Mukhopadhyay, Satyajit
    Jana, Pritikana
    Kondapi, Anand K.
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2023, 91 (05) : 375 - 387