Effectiveness of robust optimization against geometric uncertainties in TomoHelical planning for prostate cancer

被引:4
|
作者
Yagihashi, Takayuki [1 ,2 ]
Inoue, Kazumasa [2 ]
Nagata, Hironori [1 ]
Yamanaka, Masashi [1 ,3 ]
Yamano, Akihiro [1 ]
Suzuki, Shunsuke [1 ,4 ]
Yamakabe, Wataru [1 ]
Sato, Naoki [1 ]
Omura, Motoko [5 ]
Inoue, Tatsuya [1 ,6 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Med Phys, Kamakura, Kanagawa, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Human Hlth Sci, Arakawa Ku, Tokyo, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Med Phys Lab, Suita, Osaka, Japan
[4] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto, Japan
[5] Shonan Kamakura Gen Hosp, Dept Radiat Oncol, Kamakura, Kanagawa, Japan
[6] Juntendo Univ, Dept Radiat Oncol, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
来源
关键词
helical tomotherapy; intensity-modulated radiotherapy; localized prostate cancer; minimax robust optimization; MODULATED ARC THERAPY; HELICAL TOMOTHERAPY; PROTON THERAPY; RADIATION-THERAPY; RADIOTHERAPY; HEAD; RANGE; SETUP; IMRT; VMAT;
D O I
10.1002/acm2.13881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundGeometrical uncertainties in patients can severely affect the quality of radiotherapy. PurposeWe evaluated the dosimetric efficacy of robust optimization for helical intensity-modulated radiotherapy (IMRT) planning in the presence of patient setup uncertainty and anatomical changes. MethodsTwo helical IMRT plans for 10 patients with localized prostate cancer were created using either minimax robust optimization (robust plan) or a conventional planning target volume (PTV) margin approach (PTV plan). Plan robustness was evaluated by creating perturbed dose plans with setup uncertainty from isocenter shifts and anatomical changes due to organ variation. The magnitudes of the geometrical uncertainties were based on the patient setup uncertainty considered during robust optimization, which was identical to the PTV margin. The homogeneity index, and target coverage (TC, defined as the V100% of the clinical target volume), and organs at risk (OAR; rectum and bladder) doses were analyzed for all nominal and perturbed plans. A statistical t-test was performed to evaluate the differences between the robust and PTV plans. ResultsComparison of the nominal plans showed that the robust plans had lower OAR doses and a worse homogeneity index and TC than the PTV plans. The evaluations of robustness that considered setup errors more than the PTV margin demonstrated that the worst-case perturbed scenarios for robust plans had significantly higher TC while maintaining lower OAR doses. However, when anatomical changes were considered, improvement in TC from robust optimization was not observed in the worst-case perturbed plans. ConclusionsFor helical IMRT planning in localized prostate cancer, robust optimization provides benefits over PTV margin-based planning, including better OAR sparing, and increased robustness against systematic patient-setup errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Robust optimization of VMAT for prostate cancer accounting for geometric uncertainty
    Wada, Takuya
    Kawahara, Daisuke
    Murakami, Yuji
    Nakashima, Takeo
    Nagata, Yasushi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09):
  • [2] Prostate cancer EBRT: adaptive strategy and use of robust optimization for geometrical uncertainties
    Ferrara, E.
    Beldi, D.
    Yin, J.
    Loi, G.
    Krengli, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S833 - S833
  • [3] Generation of prescriptions robust against geometric uncertainties in dose painting by numbers
    Sterpin, Edmond
    Differding, Sarah
    Jansses, Guillaume
    Geets, Xavier
    Gregoire, Vincent
    Lee, John A.
    [J]. ACTA ONCOLOGICA, 2015, 54 (02) : 253 - 260
  • [4] Effectiveness of Robust Optimization in Oropharynx IMPT Planning
    Liu, W.
    Mohan, R.
    Zhang, X.
    Zhu, X. R.
    Frank, S. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S443 - S443
  • [5] Robust Topology Optimization for Structures Considering Spatially Bounded Geometric Uncertainties
    Zheng J.
    Ding S.
    Jiang C.
    [J]. Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2023, 59 (11): : 159 - 170
  • [6] Adaptive Strategy for External Beam Radiotherapy in Prostate Cancer and Management of the Geometrical Uncertainties with Robust Optimization
    Krengli, M.
    Loi, G.
    Ferrara, K.
    Beldi, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E781 - E781
  • [7] Impact of geometric uncertainties on evaluation of treatment techniques for prostate cancer
    Craig, T
    Wong, E
    Bauman, G
    Battista, J
    Van Dyk, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02): : 426 - 436
  • [8] Application of robust optimization in prostate cancer
    Alber, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2535 - 2535
  • [9] Robust topology optimization of frame structures under geometric or material properties uncertainties
    Changizi, Navid
    Jalalpour, Mehdi
    [J]. STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2017, 56 (04) : 791 - 807
  • [10] Robust topology optimization of frame structures under geometric or material properties uncertainties
    Navid Changizi
    Mehdi Jalalpour
    [J]. Structural and Multidisciplinary Optimization, 2017, 56 : 791 - 807