Biomechanical evaluation of a novel anterior transpedicular screw-plate system for anterior cervical corpectomy and fusion (ACCF): a finite element analysis

被引:1
|
作者
Huang, Shengbin [1 ,2 ]
Ling, Qinjie [3 ]
Lin, Xinxin [2 ]
Qin, Hao [2 ]
Luo, Xiang [2 ]
Huang, Wenhua [1 ,4 ]
机构
[1] Guangxi Med Univ, Sch Basic Med Sci, Dept Human Anat, Nanning, Guangxi, Peoples R China
[2] Guangxi Med Univ, Dept Cardiol, Affiliated Hosp 8, Guigang, Peoples R China
[3] Guangzhou Med Univ, Dept Spinal Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[4] Southern Med Univ, Guangdong Engn Res Ctr Translat Med 3D Printing Ap, Guangdong Prov Key Lab Med Biomech, Sch Basic Med Sci,Natl Key Discipline Human Anat, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
cervical spine; anterior pedicle screw; anterior surgery; corpectomy; reconstruction; biomechanics; finite element analysis; PULL-OUT STRENGTH; PEDICLE-SCREW; FIXATION; SPINE; RECONSTRUCTION; STABILITY; 4-LEVEL; INJURY; LOAD;
D O I
10.3389/fbioe.2023.1260204
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background and objective: Cervical fusion with vertebral body screw (VBS)-plate systems frequently results in limited biomechanical stability. To address this issue, anterior transpedicular screw (ATPS) fixation has been developed and applied preliminarily to multilevel spinal fusion, osteoporosis, and three-column injury of the cervical spine. This study aimed to compare the biomechanical differences between unilateral ATPS (UATPS), bilateral ATPS (BATPS), and VBS fixation using finite element analysis.Materials and methods: A C6 corpectomy model was performed and a titanium mesh cage (TMC) and bone were implanted, followed by implantation of a novel ATPS-plate system into C5 and C7 to simulate internal fixation with UATPS, BATPS, and VBS. Internal fixation with UATPS comprises ipsilateral transpedicular screw-contralateral vertebral body screw (ITPS-CVBS) and cross transpedicular screw-vertebral body screw (CTPS-VBS) fixations. Mobility, the maximal von Mises stress on TMC, the stress distribution and maximal von Mises stress on the screws, and the maximum displacement of the screw were compared between the four groups.Results: Compared with the original model, each group had a reduced range of motion (ROM) under six loads. After ACCF, the stress was predominantly concentrated at two-thirds of the length from the tail of the screw, and it was higher on ATPS than on VBS. The stress of the ATPS from the cranial part was higher than that of the caudal part. The similar effect happened on VBS. The screw stress cloud maps did not show any red areas reflective of a concentration of the stress on VBS. Compared with VBS, ATPS can bear a greater stress from cervical spine movements, thus reducing the stress on TMC. The maximal von Mises stress was the lowest with bilateral transpedicular TMC and increased with cross ATPS and with ipsilateral ATPS. ITPS-CVBS, CTPS-VBS, and BATPS exhibited a reduction of 2.3%-22.1%, 11.9%-2.7%, and 37.9%-64.1% in the maximum displacement of screws, respectively, compared with that of VBS.Conclusion: In FEA, the comprehensive stability ranked highest for BATPS, followed by CTPS-VBS and ITPS-CVBS, with VBS demonstrating the lowest stability. Notably, utilizing ATPS for fixation has the potential to reduce the occurrence of internal fixation device loosening after ACCF when compared to VBS.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Biomechanical evaluation of the novel assembled internal fixed system in C2-C3 anterior cervical discectomy and fusion: a finite element analysis
    Chen, Hu
    Sun, Hao
    Cao, Lu
    Xia, Hong
    Tu, Qiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [22] Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique
    Koller, Heiko
    Schmoelz, Werner
    Zenner, Juliane
    Auffarth, Alexander
    Resch, Herbert
    Hitzl, Wolfgang
    Malekzadeh, Davud
    Ernstbrunner, Lukas
    Blocher, Martina
    Mayer, Michael
    EUROPEAN SPINE JOURNAL, 2015, 24 (12) : 2848 - 2856
  • [23] Measurement of anatomical parameters of anterior transpedicular root screw intervertebral fusion system of cervical spine
    Ye, Sen-qi
    Zhao, Liu-jun
    Hou, Zhi-peng
    Zhang, Ji-hui
    Yu, Liang
    Gu, Yong-jie
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [24] Biomechanical Comparison of Anterior Lumbar Screw-plate Fixation versus Posterior Lumbar Pedicle Screw Fixation
    刘列华
    郭从涛
    周强
    蒲小兵
    宋磊
    王浩明
    赵晨
    成仕明
    兰阳军
    刘岭
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2014, 34 (06) : 907 - 911
  • [25] Measurement of anatomical parameters of anterior transpedicular root screw intervertebral fusion system of cervical spine
    Sen-qi Ye
    Liu-jun Zhao
    Zhi-peng Hou
    Ji-hui Zhang
    Liang Yu
    Yong-jie Gu
    BMC Musculoskeletal Disorders, 24
  • [26] ANTERIOR CERVICAL FIXATION WITH THE TITANIUM LOCKING SCREW-PLATE - A PRELIMINARY-REPORT
    TOMINAGA, T
    KOSHU, K
    MIZOI, K
    YOSHIMOTO, T
    SURGICAL NEUROLOGY, 1994, 42 (05): : 408 - 413
  • [27] Anterior Corpectomy With Fusion in Combination With an Anterior Cervical Plate in the Management of Ossification of the Posterior Longitudinal Ligament
    Odate, Seiichi
    Shikata, Jitsuhiko
    Kimura, Hiroaki
    Yamamura, Satoru
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (03): : 133 - 137
  • [28] Biomechanical comparison of anterior lumbar screw-plate fixation versus posterior lumbar pedicle screw fixation
    Lie-hua Liu
    Cong-tao Guo
    Qiang Zhou
    Xiao-bing Pu
    Lei Song
    Hao-ming Wang
    Chen Zhao
    Shi-ming Cheng
    Yang-jun Lan
    Ling Liu
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 907 - 911
  • [29] Biomechanical analysis of interbody and posterolateral fusion with transpedicular screw fixation for spondylolisthesis: A finite element study
    Liu, Heng-Liang
    Sun, Ming-Tsung
    Lin, Chun-Li
    Cheng, Hsin-Yi
    Wei, Kou-Chen
    Su, Wen-Kai
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2008, 20 (03): : 145 - 151
  • [30] Biomechanical comparison of anterior lumbar screw-plate fixation versus posterior lumbar pedicle screw fixation
    Liu, Lie-hua
    Guo, Cong-tao
    Zhou, Qiang
    Pu, Xiao-bing
    Song, Lei
    Wang, Hao-ming
    Zhao, Chen
    Cheng, Shi-ming
    Lan, Yang-jun
    Liu, Ling
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (06) : 907 - 911