Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy

被引:6
|
作者
Huang, Xinyue [1 ]
Hooshangnejad, Hamed [1 ,2 ]
China, Debarghya [1 ]
Feng, Ziwei [2 ,3 ]
Lee, Junghoon [2 ]
Bell, Muyinatu A. Lediju [3 ]
Ding, Kai [2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
gastrointestinal malignancies; pancreatic cancer; abdominal motion monitoring; ultrasound imaging; flexible array transducer; ABSORBABLE RADIOPAQUE HYDROGEL; RESPIRATORY MOTION; TUMOR MOTION; RADIOTHERAPY; TRACKING; SYSTEM; INTEGRATION; TARGETS;
D O I
10.3390/cancers15133294
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Ultrasound (US) imaging has been widely used for tumor tracking in image-guided radiotherapy. The quality of US images using conventional probes highly depends on user proficiency and anatomical changes, which has severely hindered the use of US-based organ motion monitoring for pancreatic cancer. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. At the same time, its strength and flexible geometry also makes the image reconstruction and delay-and-sum (DAS) beamforming very challenging. Inaccuracy in delay calculation results in defocused and distorted US images. In this study, we proposed a novel shape estimation for flexible array transducer to enhance abdomen motion monitoring. Pancreatic cancer with less than 10% 3-year survival rate is one of deadliest cancer types and greatly benefits from enhanced radiotherapy. Organ motion monitoring helps spare the normal tissue from high radiation and, in turn, enables the dose escalation to the target that has been shown to improve the effectiveness of RT by doubling and tripling post-RT survival rate. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. We proposed a novel shape estimation for flexible array transducer using two sequential algorithms: (i) an optical tracking-based system that uses the optical markers coordinates attached to the probe at specific positions to estimate the array shape in real-time and (ii) a fully automatic shape optimization algorithm that automatically searches for the optimal array shape that results in the highest quality reconstructed image. We conducted phantom and in vivo experiments to evaluate the estimated array shapes and the accuracy of reconstructed US images. The proposed method reconstructed US images with low full-width-at-half-maximum (FWHM) of the point scatters, correct aspect ratio of the cyst, and high-matching score with the ground truth. Our results demonstrated that the proposed methods reconstruct high-quality ultrasound images with significantly less defocusing and distortion compared with those without any correction. Specifically, the automatic optimization method reduced the array shape estimation error to less than half-wavelength of transmitted wave, resulting in a high-quality reconstructed image.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Design and Fabrication of a Piezoelectric Micromachined Ultrasound Array Transducer for Photoacoustic Imaging Applications
    Ahn, Hongmin
    Sung, Min
    Been, Kyounghun
    Moon, Wonkyu
    2014 11TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2014, : 73 - 76
  • [42] A 2-D Circular Array Transducer for Endoscopic Ultrasound Imaging of Tube
    Xi, Ze
    Feng, Chenkai
    Wang, Xiangang
    Luo, Xiaowei
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (01) : 87 - 99
  • [43] A flexible piezoelectric micromachined ultrasound transducer
    Yang, Yi
    Tian, He
    Yan, Bing
    Sun, Hui
    Wu, Can
    Shu, Yi
    Wang, Li-Gang
    Ren, Tian-Ling
    RSC ADVANCES, 2013, 3 (47) : 24900 - 24905
  • [44] Feasibility of Using Ultrasound to Monitor Intrafraction Motion During Radiation Therapy for Pancreatic Cancer
    Noid, G.
    Paulson, E. S.
    Prah, D.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S837 - S837
  • [45] Numerical study on high intensity focused ultrasound therapy using array transducer
    Okita, Kohei
    Sugiyama, Kazuyasu
    Ono, Kenji
    Takagi, Shu
    Matsumoto, Yoichiro
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 315 - 322
  • [46] A cylindrical phased-array ultrasound transducer for breast tumor thermal therapy
    Ho, CS
    Ju, KC
    Chen, YY
    Lin, WL
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1724 - 1727
  • [47] Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging
    Daoudi, K.
    van den Berg, P. J.
    Rabot, O.
    Kohl, A.
    Tisserand, S.
    Brands, P.
    Steenbergen, W.
    OPTICS EXPRESS, 2014, 22 (21): : 26365 - 26374
  • [48] Radiation therapy approaches in pancreatic cancer
    Roeder, Falk
    THERAPEUTISCHE UMSCHAU, 2016, 73 (09) : 515 - 522
  • [49] Radiation Therapy for hepatobiliary and pancreatic cancer
    Sakurai, Hideyuki
    Okumura, Toshiyuki
    Ishikawa, Hitoshi
    Nonaka, Tetsuo
    Numajiri, Haruko
    Mizumoto, Masashi
    Ohnishi, Kayoko
    Murofushi, Keiko
    Sekino, Yuta
    Mizoguchi, Nobutaka
    Iizumi, Takashi
    Miyauchi, Daigo
    CANCER SCIENCE, 2018, 109 : 374 - 374
  • [50] Radiation Plus Ultrasound: From Imaging to Therapy
    Xiang, Liangzhong
    Patch, S.
    Malliddi, S.
    Song, P.
    Xiang, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E470 - E471