Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy

被引:6
|
作者
Huang, Xinyue [1 ]
Hooshangnejad, Hamed [1 ,2 ]
China, Debarghya [1 ]
Feng, Ziwei [2 ,3 ]
Lee, Junghoon [2 ]
Bell, Muyinatu A. Lediju [3 ]
Ding, Kai [2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
gastrointestinal malignancies; pancreatic cancer; abdominal motion monitoring; ultrasound imaging; flexible array transducer; ABSORBABLE RADIOPAQUE HYDROGEL; RESPIRATORY MOTION; TUMOR MOTION; RADIOTHERAPY; TRACKING; SYSTEM; INTEGRATION; TARGETS;
D O I
10.3390/cancers15133294
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Ultrasound (US) imaging has been widely used for tumor tracking in image-guided radiotherapy. The quality of US images using conventional probes highly depends on user proficiency and anatomical changes, which has severely hindered the use of US-based organ motion monitoring for pancreatic cancer. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. At the same time, its strength and flexible geometry also makes the image reconstruction and delay-and-sum (DAS) beamforming very challenging. Inaccuracy in delay calculation results in defocused and distorted US images. In this study, we proposed a novel shape estimation for flexible array transducer to enhance abdomen motion monitoring. Pancreatic cancer with less than 10% 3-year survival rate is one of deadliest cancer types and greatly benefits from enhanced radiotherapy. Organ motion monitoring helps spare the normal tissue from high radiation and, in turn, enables the dose escalation to the target that has been shown to improve the effectiveness of RT by doubling and tripling post-RT survival rate. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. We proposed a novel shape estimation for flexible array transducer using two sequential algorithms: (i) an optical tracking-based system that uses the optical markers coordinates attached to the probe at specific positions to estimate the array shape in real-time and (ii) a fully automatic shape optimization algorithm that automatically searches for the optimal array shape that results in the highest quality reconstructed image. We conducted phantom and in vivo experiments to evaluate the estimated array shapes and the accuracy of reconstructed US images. The proposed method reconstructed US images with low full-width-at-half-maximum (FWHM) of the point scatters, correct aspect ratio of the cyst, and high-matching score with the ground truth. Our results demonstrated that the proposed methods reconstruct high-quality ultrasound images with significantly less defocusing and distortion compared with those without any correction. Specifically, the automatic optimization method reduced the array shape estimation error to less than half-wavelength of transmitted wave, resulting in a high-quality reconstructed image.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Shape Estimation Algorithm for Ultrasound Imaging by Flexible Array Transducer
    Noda, Takumi
    Tomii, Naoki
    Nakagawa, Keiichi
    Azuma, Takashi
    Sakuma, Ichiro
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) : 2345 - 2353
  • [2] A Flexible Ultrasound Transducer Array Patch
    Zhang, Wenjie
    Ma, Tiancheng
    Han, Liuyang
    Zhao, Liuyan
    Liu, Jie
    Dong, Ying
    Wang, Xiaohao
    25TH ANNUAL CONFERENCE & 14TH INTERNATIONAL CONFERENCE OF THE CHINESE SOCIETY OF MICRO-NANO TECHNOLOGY, CSMNT 2023, 2024, 2740
  • [3] Shape Sensing with Electrostatic Differential Capacitance for Ultrasound Imaging by Flexible Array Transducer
    Hojo, Chisato
    Kawagishi, Hiroki
    Shigemune, Hiroki
    Tsumura, Ryosuke
    2023 IEEE INTERNATIONAL CONFERENCE ON SOFT ROBOTICS, ROBOSOFT, 2023,
  • [4] AN INTEGRATED MULTIELEMENT ARRAY TRANSDUCER FOR ULTRASOUND IMAGING
    HATFIELD, JV
    SCALES, NR
    ARMITAGE, AD
    HICKS, PJ
    CHEN, QX
    PAYNE, PA
    SENSORS AND ACTUATORS A-PHYSICAL, 1994, 41 (1-3) : 167 - 173
  • [5] AN INTEGRATED ARRAY TRANSDUCER RECEIVER FOR ULTRASOUND IMAGING
    ARMITAGE, AD
    SCALES, NR
    HICKS, PJ
    PAYNE, PA
    CHEN, QX
    HATFIELD, JV
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 47 (1-3) : 542 - 546
  • [6] Deep Learning for Ultrasound Beamforming in Flexible Array Transducer
    Huang, Xinyue
    Bell, Muyinatu A. Lediju
    Ding, Kai
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (11) : 3178 - 3189
  • [7] Multilayer Array Transducer for Nonlinear Ultrasound Imaging
    Owen, Neil R.
    Kaczkowski, Peter J.
    Li, Tong
    Gross, Dan
    Postlewait, Steven M.
    Curra, Francesco P.
    10TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND (ISTU 2010), 2011, 1359 : 206 - 210
  • [8] MATRIX ARRAY TRANSDUCER AND FLEXIBLE MATRIX ARRAY TRANSDUCER
    KOJIMA, T
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (03) : 416 - 416
  • [9] Integrated thermoacoustic and ultrasound imaging based on the combination of a hollow concave transducer array and a linear transducer array
    Wang, Xue
    Huang, Lin
    Chi, Zihui
    Jiang, Huabei
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11):
  • [10] Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer
    Su, Lin
    Iordachita, Iulian
    Zhang, Yin
    Lee, Junghoon
    Ng, Sook Kien
    Jackson, Juan
    Hooker, Ted
    Wong, John
    Herman, Joseph M.
    Sen, H. Tutkun
    Kazanzides, Peter
    Bell, Muyinatu A. Lediju
    Yang, Chen
    Ding, Kai
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 84 - 96