Fabrication and evaluation of optical nanobiosensor based on localized surface plasmon resonance (LSPR) of gold nanorod for detection of CRP

被引:27
|
作者
Hosseinniay, Sam [1 ]
Rezayan, Ali Hossein [1 ]
Ghasemi, Forough [2 ]
Malekmohamadi, Marjan [1 ]
Taheri, Ramezan Ali [3 ]
Hosseini, Morteza [1 ]
Alvandi, Hale [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Div Nanobiotechnol, POB 14395-1561, Tehran, Iran
[2] Agr Res Educ & Extens Org AREEO, Agr Biotechnol Res Inst Iran, Dept Nanotechnol, ABRII, Karaj, Iran
[3] Baqiyatallah Univ Med Sci, Nanobiotechnol Res Ctr, Tehran, Iran
关键词
Gold-nanorod; Aptamer-based nanobiosensor; LSPR; CRP; Sepsis; Cardiovascular diseases (CVD); C-REACTIVE PROTEIN; FTIR SPECTROSCOPY; SCALE SYNTHESIS; NANOPARTICLES; DISEASE; SIZE; POLYNUCLEOTIDES; SENSITIVITY; BIOSENSOR; SELECTION;
D O I
10.1016/j.aca.2022.340580
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
C-reactive protein (CRP) is a plasma protein that is one of the most expressed proteins in acute phase inflammation cases. It is a well-known biomarker for inflammatory disorders. There is a significant correlation between increasing CRP concentration and the risk of being exposed to cardiovascular diseases (CVD) and sepsis; thus, monitoring and quantifying CRP levels in a simple, inexpensive, and quick manner can improve clinical diagnostics and help prevent major inflammatory conditions. Here a nanobiosensor was developed, benefiting from the LSPR property of gold-nanorod (GNR) to measure CRP concentration. Nanorods were fabricated using One-pot synthesis by trimethyl ammonium bromide (CTAB) as a surfactant. This method provides the advantage of both step and time reduction in synthesis and decreases the contamination probability of nanorods as the products. The nanorods were characterized using TEM with an average size of (24 +/- 1 nm) x (5 +/- 1 nm) and a typical aspect ratio of similar to 4.9. The surface of the rods was modified with a specific aptamer for the target protein, and the LSPR shifts due to the gold nanorod's refractive index change as the result of protein interaction with the biosensor investigated using a 100-900 nm UV absorption device. The results indicated that the nanobiosensor could respond to different CRP concentrations within 30 min. The selectivity test has shown nonresponsive results of nanobiosensor to BSA and TNF-alpha proteins which are used to evaluate the biosensor behavior in non-target proteins. The detection limit was evaluated at 2 nM, and the sensor's linear response ranged between 2 - 20 nM.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Amplification of localized surface plasmon resonance signals by a gold nanorod assembly and ultra-sensitive detection of mercury
    Huang, Haowen
    Qu, Caiting
    Liu, Xuanyong
    Huang, Shaowen
    Xu, Zhongjian
    Zhu, Yingjie
    Chu, Paul K.
    CHEMICAL COMMUNICATIONS, 2011, 47 (24) : 6897 - 6899
  • [42] Effects of Aspect Ratio Heterogeneity of an Assembly of Gold Nanorod on Localized Surface Plasmon Resonance
    Kaushal, Sandeep
    Nanda, Sitansu Sekhar
    Yi, Dong Kee
    Ju, Heongkyu
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2020, 11 (15): : 5972 - 5979
  • [43] Enhanced Biomolecular Detection Based on Localized Surface Plasmon Resonance (LSPR) Using Enzyme-Precipitation Reaction
    Lee, Seung-Woo
    Ahn, Junhyoung
    Kim, Min-Gon
    Shin, Yong-Beom
    Lee, Jae Jong
    Lim, Ki-Pil
    Kim, Ki-Bum
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2010, 10 (05) : 3246 - 3249
  • [44] Optical detection of single non-absorbing molecules using the surface plasmon resonance of a gold nanorod
    Zijlstra, Peter
    Paulo, Pedro M. R.
    Orrit, Michel
    NATURE NANOTECHNOLOGY, 2012, 7 (06) : 379 - 382
  • [45] Optical detection of single non-absorbing molecules using the surface plasmon resonance of a gold nanorod
    Peter Zijlstra
    Pedro M. R. Paulo
    Michel Orrit
    Nature Nanotechnology, 2012, 7 (6) : 379 - 382
  • [46] In-direct localized surface plasmon resonance (LSPR)-based nanosensors for highly sensitive and rapid detection of cortisol
    Jeon, Jinwoo
    Uthaman, Saji
    Lee, Jiyoung
    Hwang, Hyejin
    Kim, Gibum
    Yoo, Pil J.
    Hammock, Bruce D.
    Kim, Christine S.
    Park, Yeon-Su
    Park, In-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 : 710 - 716
  • [47] Signal Amplification by Enzymatic Reaction in an Immunosensor Based on Localized Surface Plasmon Resonance (LSPR)
    Lee, Tae-Han
    Lee, Seung-Woo
    Jung, Ji-Ae
    Ahn, Junhyoung
    Kim, Min-Gon
    Shin, Yong-Beom
    SENSORS, 2010, 10 (03): : 2045 - 2053
  • [48] Optical Sensing Based on Localized Surface Plasmon Resonance
    Zhu, Shaoli
    Zhou, Wei
    ADVANCED PRECISION ENGINEERING, 2010, 447-448 : 584 - 589
  • [49] Application of Surface Click Reactions to Localized Surface Plasmon Resonance (LSPR) Biosensing
    Yaakov, Noga
    Chaikin, Yulia
    Wexselblatt, Ezequiel
    Tor, Yitzhak
    Vaskevich, Alexander
    Rubinstein, Israel
    CHEMISTRY-A EUROPEAN JOURNAL, 2017, 23 (42) : 10148 - 10155
  • [50] Detection of SO2 at the ppm Level with Localized Surface Plasmon Resonance (LSPR) Sensing
    Takimoto, Yuki
    Monkawa, Akira
    Nagata, Kohki
    Kobayashi, Masahiro
    Kinoshita, Mariko
    Gessei, Tomoko
    Mori, Toshiya
    Kagi, Hiroyuki
    PLASMONICS, 2020, 15 (03) : 805 - 811