Segmental instability failures in transmission line towers

被引:3
|
作者
Rao, N. Prasad [1 ]
Rokade, R. P. [1 ]
Balagopal, R. [1 ]
Palani, G. S. [1 ]
机构
[1] CSIR Struct Engn Res Ctr, CSIR Rd, Chennai 600113, Tamil Nadu, India
关键词
Transmission line tower; Segment instability; Staggered bracing; Leg-bracing inclination; Diaphragm bracing; COLLAPSE ANALYSIS; MECHANISM; BEHAVIOR;
D O I
10.1016/j.jcsr.2023.108195
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of the detailed studies conducted on premature failures of transmission line towers during full-scale testing. Configuration and proportioning of base width, hamper width, the height of each segment and selection of bracing patterns play a vital role in providing geometric stability to the tower. In the present study, three towers of different voltage clauses failed during testing, investigated and found that geometric instability caused the premature failure. In the case of a 500 kV tower with a rectangular configuration, the staggered bracing pattern continuously for multiple segments for about 20 m height without a diaphragm bracing in between caused geometric instability in the tower. Nonlinear FEA results of the tower modelled with diaphragm bracing showed that tower failure can be prevented by introducing diaphragm bracing at different heights. The 400 kV double circuit dead-end type tower with a 15 m height bottom segment and 161 kV suspension towers analysed based on the conventional static analysis ignoring geometric instability failed prematurely and FE analysis clearly shows the failure due to geometric instability. It is recommended to divide the single segment into two segments such that the included angle between the leg and primary bracing member can be increased, and thereby additional moments in the leg members are reduced by making the bracing member contribute to sharing the shear. The code recommended minimum included angle of 15 degrees between the leg and primary bracing member is only a guiding parameter for the designers. Based on this study, it is recommended that the designers shall check the tower geometry for segmental / panel instability by modelling and nonlinear FE analysis of the tower with beam elements in place of conventional space truss elements.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Thor – a New Design of Overhead Transmission Line Towers
    Schmidt, Mark Kokborg
    Nielsen, Mogens G.
    Endahl, Brian
    Steenholt-Eliasson, Karl Emil
    ce/papers, 2019, 3 (3-4): : 403 - 408
  • [22] OPTIMUM ARRANGEMENT OF TOWERS IN AN ELECTRIC POWER TRANSMISSION LINE
    RANYARD, JC
    WREN, A
    COMPUTER JOURNAL, 1967, 10 (02): : 157 - &
  • [23] LIFTING OF TRANSMISSION TOWERS UNDER LIVE LINE CONDITIONS
    SKELTON, HE
    ORDE, CI
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (09): : 3018 - 3021
  • [24] OPTIMUM CONFIGURATION STUDY OF TRANSMISSION LINE TOWERS.
    Kapoor, M.P.
    Kumaraswamy, K.
    Irrigation and Power, 1980, 37 (03): : 359 - 369
  • [25] Transmission line failures during tornadoes and downbursts
    El Damatty, Ashraf
    Elawady, Amal
    Hamada, Mohamed
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 2022 - 2027
  • [26] Comparative Study of Design Inputs of Overhead Transmission Line Towers
    Aluthwaththa, A. G. H. A. D.
    Baskaran, K.
    MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON 2021) / 7TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2021, : 397 - 402
  • [27] Analysis of Methods to Reduce the Ground Resistance of Transmission Line Towers
    Smohai, Balazs
    Ladanyi, Jozsef
    2015 5TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY (IYCE), 2015,
  • [28] Seismic analysis of transmission towers under various line configurations
    Lei, Y. H.
    Chien, Y. L.
    STRUCTURAL ENGINEERING AND MECHANICS, 2009, 31 (03) : 241 - 264
  • [29] Fragility modelling framework for transmission line towers under winds
    Cai, Yunzhu
    Xie, Qiang
    Xue, Songtao
    Hu, Liang
    Kareem, Ahsan
    ENGINEERING STRUCTURES, 2019, 191 : 686 - 697
  • [30] TRANSMISSION-LINE LIGHTNING PERFORMANCE WITH SURGE SUPPRESSORS AT TOWERS
    LOS, EJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01): : 5 - 5