Segmental instability failures in transmission line towers

被引:3
|
作者
Rao, N. Prasad [1 ]
Rokade, R. P. [1 ]
Balagopal, R. [1 ]
Palani, G. S. [1 ]
机构
[1] CSIR Struct Engn Res Ctr, CSIR Rd, Chennai 600113, Tamil Nadu, India
关键词
Transmission line tower; Segment instability; Staggered bracing; Leg-bracing inclination; Diaphragm bracing; COLLAPSE ANALYSIS; MECHANISM; BEHAVIOR;
D O I
10.1016/j.jcsr.2023.108195
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of the detailed studies conducted on premature failures of transmission line towers during full-scale testing. Configuration and proportioning of base width, hamper width, the height of each segment and selection of bracing patterns play a vital role in providing geometric stability to the tower. In the present study, three towers of different voltage clauses failed during testing, investigated and found that geometric instability caused the premature failure. In the case of a 500 kV tower with a rectangular configuration, the staggered bracing pattern continuously for multiple segments for about 20 m height without a diaphragm bracing in between caused geometric instability in the tower. Nonlinear FEA results of the tower modelled with diaphragm bracing showed that tower failure can be prevented by introducing diaphragm bracing at different heights. The 400 kV double circuit dead-end type tower with a 15 m height bottom segment and 161 kV suspension towers analysed based on the conventional static analysis ignoring geometric instability failed prematurely and FE analysis clearly shows the failure due to geometric instability. It is recommended to divide the single segment into two segments such that the included angle between the leg and primary bracing member can be increased, and thereby additional moments in the leg members are reduced by making the bracing member contribute to sharing the shear. The code recommended minimum included angle of 15 degrees between the leg and primary bracing member is only a guiding parameter for the designers. Based on this study, it is recommended that the designers shall check the tower geometry for segmental / panel instability by modelling and nonlinear FE analysis of the tower with beam elements in place of conventional space truss elements.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Redundant Induced Bracing Failures in Transmission Line Towers
    Rao, N. Prasad
    Balagopal, R.
    Rokade, R. P.
    Palani, G. S.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2024, : 1154 - 1164
  • [2] Cascading structural failures of towers in an electric power transmission line due to straight line winds
    Dikshit, Saransh
    Dobson, Ian
    Alipour, Alice
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 250
  • [3] LIGHTNING PERFORMANCE ON TRANSMISSION LINE TOWERS
    Sliskis, Olegs
    Dvornikovs, Ilja
    Ketners, Karlis
    ELECTRICAL AND CONTROL TECHNOLOGIES, 2012, : 157 - 160
  • [4] Failure Analysis of Transmission Line Towers
    Rao, N. Prasad
    Knight, G. M. Samuel
    Seetharaman, S.
    Lakshmanan, N.
    Iyer, Nagesh R.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2011, 25 (03) : 231 - 240
  • [5] Raising Transmission Line Steel Towers
    Dupree, Ashley
    Liu, Fang
    Rumble, Jonathon
    Ortegon, Ricardo
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 249 - 260
  • [6] TESTING OF TRANSMISSION LINE TOWERS.
    Murthy, S.S.
    Mukerjea, S.K.
    Indian Journal of Power and River Valley Development, 1973, 23 (05): : 141 - 151
  • [7] Design aids for transmission line towers
    Selvanathan, J.
    Irrigation and Power, 1988, 45 (02): : 90 - 111
  • [8] DYNAMIC LOADS ON TRANSMISSION LINE TOWERS.
    Rangaswami, R.
    Jayaraman, G.
    Santhakumar, A.R.
    Jayasekaran, T.
    Journal of the Institute of Wood Science, 1978, 1 : 455 - 460
  • [9] AN ASSESSMENT OF STAINLESS STEEL TRANSMISSION LINE TOWERS
    Silva, Geziel
    Silva, Andre
    Vellasco, Pedro
    Lima, Luciano
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [10] OPTIMUM DESIGNS FOR TRANSMISSION-LINE TOWERS
    RAO, GV
    COMPUTERS & STRUCTURES, 1995, 57 (01) : 81 - 92