Regenerator performance using freezing concentration for heat source tower heat pump system

被引:5
|
作者
Han, Chong [1 ,2 ]
Yu, Muyang [1 ,2 ]
Hou, Chongchong [1 ,2 ]
Jiang, Huimin [3 ]
Chen, Chuanbao [3 ]
Yao, Yang [1 ,2 ]
Ni, Long [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement En, Harbin, Peoples R China
[3] Nanjing Wuzhou Refrigerat Grp Co Ltd, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat source tower heat pump; Freeze concentration; Refrigeration; Heat transfer; Freezing process; DESICCANT;
D O I
10.1016/j.applthermaleng.2023.121053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Freeze concentration has a good regeneration effect and is easy for latent heat utilization. The electronic expansion valve opening has a great impact on the icing process. Hence, to investigate variations in the freezing process and gain the optimum regeneration effect, a solution regenerator was tested under different system-side control strategies. The solution volume flow was 5 m3/h and the electronic expansion valve opening degree (OEEV) was from 100% to 50%. For ice-covering growth, ice in low opening degree spent a long time to cover the plate. The area of ice under 100% to 65% OEEV was 1.43 times that under 50% OEEV. Peak velocities from 100% to 50% OEEV all appeared in the early stage of icing development. Moreover, the low opening degree made the ice distribute unevenness. The percentage slope of 100% OEEV was 1.23% and that of 50% OEEV was 3.46%. In addition, decreasing ice thickness uniformity was beneficial to the separation process. The separation ratio from 100% to 50% OEEV was 49.51%, 51.67%, 57.88%, and 74.54%, respectively. Both the low average thickness growth rate and high separation ratio were beneficial to increase the regeneration concentration. The effective specific ice production rate was from 100% to 50% OEEV was 5.99 kg/kWh, 6.18 kg/kWh, 6.94 kg/kWh, and 6.88 kg/kWh, respectively. Results showed that 65% OEEV operation was optimum for the solution regenerator unit using freeze concentration.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Experimental investigation on heating performance of a solution regenerator unit using freezing concentration for heat source tower heat pump system
    Han, Chong
    Chen, Xinzhuo
    Wu, Shangshu
    Ni, Long
    ENERGY AND BUILDINGS, 2024, 312
  • [2] Experimental investigation on the melting process using freezing concentration for heat source tower heat pump system
    Han, Chong
    Hou, Chongchong
    Jiang, Shuai
    Jiang, Huimin
    Yao, Yang
    Ni, Long
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [3] Experimental investigation on the feasibility of a solution regenerator unit using freeze concentration for heat source tower heat pump system
    Han, Chong
    Jiang, Huimin
    Yao, Yang
    Ni, Long
    ENERGY AND BUILDINGS, 2023, 284
  • [4] Experimental investigation of a heat-source tower heat pump with self-regenerator using subcooling heat
    Xiao, Hansong
    Song, Pengyuan
    Wang, Baolong
    Li, Zhiming
    Shi, Wenxing
    Yang, Zixu
    Li, Xianting
    Huang, Yunsong
    Liang, Zhihui
    ENERGY AND BUILDINGS, 2021, 240
  • [5] Study of Heat-source-tower Heat Pump System Efficiency
    Cheng, Jianlin
    Li, Nianpin
    Wang, Kuan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 915 - 921
  • [6] PERFORMANCE ASSESSMENT OF A COOLING TOWER AND A GROUND SOURCE HEAT PUMP FOR HEAT DISSIPATION
    Moreira, Daniel
    Zabala, Gonzalo
    Villanueva, Ruben
    Soriano, Guillermo
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017 VOL 6, 2018,
  • [7] Performance investigation of a novel heating tower heat pump system with integrated air gap membrane distillation regenerator
    Wang, Li
    Cui, Haijiao
    Fu, Cong
    ENERGY CONVERSION AND MANAGEMENT, 2021, 232
  • [8] Theoretical analysis on characteristics of freezing and performance of heat transfer in heat pump system with freezing latent heat collection
    Qian, Jianfeng
    Sun, Dexing
    Zhang, Chenghu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (11): : 1200 - 1205
  • [9] Construction and experimental research on heat pump system based on heat-source tower
    Liang, Caihua
    Wen, Xiantai
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2010, 61 (SUPPL. 2): : 142 - 146
  • [10] Ground Source Heat Pump with Passive Heat Compensation Tower
    Song Yanli
    Du Tao
    Ren Dong
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 684 - 687