Variability of radiotherapy volume delineation: PSMA PET/MRI and MRI based clinical target volume and lymph node target volume for high-risk prostate cancer

被引:2
|
作者
Liu, Lin-Lin [1 ]
Zhu, Lei-Lei [1 ]
Lu, Zhen-Guo [1 ]
Sun, Jun-Die [1 ]
Zhao, Jun [2 ]
Wang, Hai-Feng [3 ]
Xiang, Zuo-Lin [1 ,4 ]
机构
[1] Tongji Univ, Shanghai East Hosp, Sch Med, Dept Radiat Oncol, Shanghai 200120, Peoples R China
[2] Tongji Univ, Shanghai East Hosp, Sch Med, Dept Nucl Med, Shanghai 200120, Peoples R China
[3] Tongji Univ, Shanghai East Hosp, Sch Med, Dept Urol, Shanghai 200120, Peoples R China
[4] Jian Hostipal, Dept Radiat Oncol, Shanghai East Hosp, Jian 343000, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Prostate cancer; PET/MRI; PSMA; Radiotherapy; CTV; GTVn; POSITRON-EMISSION-TOMOGRAPHY; RADIATION-THERAPY; EAU GUIDELINES; METASTASES; RESONANCE; UTILITY; TUMOR; PET;
D O I
10.1186/s40644-022-00518-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A comparative retrospective study to assess the impact of PSMA Ligand PET/MRI ([68 Ga]-Ga-PSMA-11 and [18F]-F-PSMA-1007 PET/MRI) as a new method of target delineation compared to conventional imaging on whole pelvis radiotherapy for high-risk prostate cancer (PCa).Patients and methods: Forty-nine patients with primary high-risk PCa completed the whole-pelvis radiotherapy plan based on PSMA PET/MRI and MRI. The primary endpoint compared the size and overlap of clinical target volume (CTV) and nodal gross tumour volume (GTVn) based on PSMA PET/MRI and MRI. The diagnostic performance of two methods for pelvic lymph node metastasis (PLNM) was evaluated. Results: In the radiotherapy planning for high-risk PCa patients, there was a significant correlation between MRI-CTV and PET/MRI-CTV (P = 0.005), as well as between MRI-GTVn and PET/MRI-GTVn (P < 0.001). There are non-significant differences in the CTV and GTVn based on MRI and PET/MRI images (P = 0.660, P = 0.650, respectively). The conformity index (CI), lesion coverage factor (LCF) and Dice similarity coefficient (DSC) of CTVs were 0.999, 0.953 and 0.954. The CI, LCF and DSC of GTVns were 0.927, 0.284, and 0.32. Based on pathological lymph node analysis of 463 lymph nodes from 37 patients, the sensitivity, specificity of PET/MRI in the diagnosis of PLNM were 77.78% and 99.76%, respectively, which were higher than those of MRI (P = 0.011). Eight high-risk PCa patients who finished PSMA PET/MRI changed their N or M stage. Conclusion: The CTV delineated based on PET/MRI and MRI differ little. The GTVn delineated based on PET/MRI encompasses metastatic pelvic lymph nodes more accurately than MRI and avoids covering pelvic lymph nodes without metastasis. We emphasize the utility of PET/MRI fusion images in GTVn delineation in whole pelvic radiotherapy for PCa. The use of PSMA PET/MRI aids in the realization of more individual and precise radiotherapy for PCa.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node optimized target volume definition
    Ganswindo, U.
    Paulsen, F.
    Glocker, S.
    Birkner, M.
    Alber, M.
    Corvin, S.
    Bares, R.
    Budach, W.
    Bamberg, M.
    Belka, C.
    EJC SUPPLEMENTS, 2005, 3 (02): : 236 - 236
  • [22] Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node optimized target volume definition
    Ganswindt, U
    Paulsen, F
    Glocker, S
    Birkner, M
    Alber, M
    Corvin, S
    Anastasiadis, A
    Eichhorn, K
    Bares, R
    Bamberg, M
    Budach, W
    Belka, C
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S320 - S320
  • [23] Exploration of the Radiotherapeutic Clinical Target Volume Delineation for Gastric Cancer from Lymph Node Metastases
    Dong, Wei
    Li, Baosheng
    Wang, Juan
    Song, Yipeng
    Zhang, Zicheng
    Fu, Chengrui
    ANTICANCER RESEARCH, 2017, 37 (08) : 4629 - 4634
  • [24] MRI-based clinical target volume delineation in gastric cancer: first results of a feasibility study
    Van Pelt, V. W. J.
    Jansen, E. P. M.
    Bartels-Rutten, A.
    Van Dieren, J. M.
    Van Sandick, J. W.
    Grootscholten, C.
    Van der Heide, U. A.
    Nowee, M.
    Verheij, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S782 - S783
  • [25] Radiotherapy for cervix carcinomas: Clinical target volume delineation
    Gnep, K.
    Mazeron, R.
    CANCER RADIOTHERAPIE, 2013, 17 (5-6): : 486 - 492
  • [26] The Impact of Interactive MRI-Based Radiologist Review on Radiotherapy Target Volume Delineation in Head and Neck Cancer
    Adjogatse, D.
    Petkar, I
    Ferreira, M. Reis
    Kong, A.
    Lei, M.
    Thomas, C.
    Barrington, S. F.
    Dudau, C.
    Touska, P.
    Urbano, T. Guerrero
    Connor, S. E. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (02) : 192 - 198
  • [27] Inter-Observer variability in MRI-based target volume delineation of uveal melanoma
    Beenakker, Jan-Willem
    Jaarsma-Coes, Myriam
    Klaassen, Lisa
    Verbist, Berit
    Vu, Khanh
    Klaver, Yvonne
    Rodrigues, Myra
    Nabarro, Claire
    Luyten, Gre
    van Herk, Marcel
    Rasch, Coen
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [28] Proposal for the delineation of the clinical target volume in biliary tract cancer radiotherapy
    Socha, J.
    Michalak, M.
    Wolakiewicz, G.
    Kepka, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S334 - S335
  • [29] SEMI-AUTOMATIC DELINEATION OF PELVIC LYMPH NODE CLINICAL TARGET VOLUME (CTV-PLN) FOR PROSTATE CANCER
    Bayley, A.
    Kong, V.
    Rosewall, T.
    Chung, P.
    Dinniwell, R.
    Shaw, M.
    Catton, C.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S39 - S40
  • [30] The Effectiveness of Radiotherapy for Upper Tract Urothelial Carcinoma (UTUC) with Lymph Node Metastasis and Optimal Target Delineation for Clinical Target Volume
    Li, X.
    Gao, X.
    Li, H.
    Qi, X.
    Ma, M. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E553 - E553