Development and validation of a UPLC-MS/MS method for the quantification of sugars and non-nutritive sweeteners in human urine

被引:7
|
作者
Diepeveen-de Bruin, Marlies [1 ]
Maho, Walid [1 ]
Buso, Marion E. C. [1 ]
Naomi, Novita D. [1 ]
Brouwer-Brolsma, Elske M. [1 ]
Feskens, Edith J. M. [1 ]
Balvers, Michiel G. J. [1 ]
机构
[1] Wageningen Univ & Res, Div Human Nutr & Hlth, POB 17, NL-6700 AA Wageningen, Netherlands
基金
欧盟地平线“2020”;
关键词
Urine; Biomarker; Sucrose; Fructose; Sweeteners; UPLC-MS; MS; Validation; LIQUID-CHROMATOGRAPHY; BIOMARKER; CONSUMPTION; SUCROSE;
D O I
10.1016/j.jchromb.2023.123741
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-intensity sweeteners ('sweeteners'), such as sucralose, saccharine, acesulfame, cyclamate and steviol, are replacing sugars in many food products, but biomarker-based data on their population-wide exposure, as well as analytical methods that can quantify urinary concentrations of sugars and sweeteners simultaneously, are lacking. Here, we developed and validated an ultra-pressure liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) method to quantify glucose, sucrose, fructose, sucralose, saccharine, acesulfame, cyclamate and steviol glucuronide in human urine. Urine samples were prepared by a simple dilution step containing the internal standards in water and methanol. Separation was achieved on a Shodex Asahipak NH2P-40 hydrophilic interaction liquid chromatography (HILIC) column using gradient elution. The analytes were detected using electrospray ionization in negative ion mode, and selective reaction monitoring was optimized using the [M -H]-ions. Calibration curves ranged between 34 and 19,230 ng/mL for glucose and fructose, and 1.8 to 1,026 ng/mL for sucrose and the sweeteners. The method has acceptable accuracy and precision, which depends on the application of appropriate internal standards. Storage of urine samples in lithium monophosphate gives the best overall analytical performance, and storage at room temperature without any preservatives should be avoided since this leads to reduced glucose and fructose concentrations. With the exception of fructose, all analytes were stable throughout 3 freeze-thaw cycles. The validated method was applied to human urine samples, demonstrating quantifiable concentrations of the analytes which were in the expected range. It is concluded that the method has acceptable performance to quantitatively determine dietary sugars and sweet-eners in human urine.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Validation of UPLC-MS/MS Method for the Determination of Cefprozil in Human Plasma
    Gan, Dongmei
    Xia, Kejun
    Shan, Shuqin
    Yu, Yue
    Shi, Xiaojun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (02): : 254 - 258
  • [22] Development and validation of a UPLC-MS/MS method for the quantification of isothiazolinones in the composition and emissions from consumer products
    de Saint Paul, Lea Ducup
    Ravier, Sylvain
    Wortham, Henri
    Maupetit, Francois
    Nicolas, Melanie
    Quivet, Etienne
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (26) : 6617 - 6626
  • [23] Development and validation of a method for quantification of residual florfenicol in various tissues of broiler chicken by UPLC-MS/MS
    Yan Zheng
    Lixia Fan
    Lingjun zhao
    Yanjie Dong
    Yancui Jiao
    Xueting Xue
    Fabin Yang
    Xuexia Yuan
    Lei Wang
    Shancang Zhao
    Journal of Food Measurement and Characterization, 2021, 15 : 3143 - 3152
  • [24] Development of a method by UPLC-MS/MS for the quantification of tizoxanide in human plasma and its pharmacokinetic application
    Marcelin-Jimenez, Gabriel
    Contreras-Zavala, Leticia
    Maggi-Castellanos, Martha
    Angeles-Moreno, Alionka P.
    Garcia-Gonzalez, Alberto
    BIOANALYSIS, 2012, 4 (08) : 909 - 917
  • [25] Development and validation of a UPLC-MS/MS method for the quantification of isothiazolinones in the composition and emissions from consumer products
    Léa Ducup de Saint Paul
    Sylvain Ravier
    Henri Wortham
    François Maupetit
    Mélanie Nicolas
    Etienne Quivet
    Analytical and Bioanalytical Chemistry, 2021, 413 : 6617 - 6626
  • [26] Development and validation of a method for quantification of residual florfenicol in various tissues of broiler chicken by UPLC-MS/MS
    Zheng, Yan
    Fan, Lixia
    Zhao, Lingjun
    Dong, Yanjie
    Jiao, Yancui
    Xue, Xueting
    Yang, Fabin
    Yuan, Xuexia
    Wang, Lei
    Zhao, Shancang
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2021, 15 (04) : 3143 - 3152
  • [27] Development and validation of an LC-MS/MS method for the quantification of artificial sweeteners in human matrices
    Greibe, Eva
    Leth-Moller, Magnus
    Stampe, Sofie
    Ovesen, Per
    Pedersen, Michael
    Hoffmann-Lucke, Elke
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (06)
  • [28] Development and validation of a UPLC-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine
    Wang, Zhenlei
    Jiang, Ji
    Hu, Pei
    Zhao, Qian
    BIOANALYSIS, 2017, 9 (04) : 381 - 393
  • [29] Development, validation, and application of an UPLC-MS/MS method for norvancomycin analysis in human blood plasma
    Mei, Shenghui
    Wang, Jiaqing
    Cheng, Qing
    Zhu, Leting
    Yang, Li
    Chen, Ruiling
    Zhao, Zhigang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1072 : 199 - 204
  • [30] Development, validation, and clinical application of a UPLC-MS/MS method for omadacycline determination in human serum
    Guo, Suhang
    Zheng, Ren
    Fan, Xudong
    Zhang, Ruoying
    Cai, Xinjun
    Jin, Jie
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2024, 127