Dark-field line confocal imaging with point confocality and extended line field for bulk defects detection

被引:2
|
作者
Dong, Jingtao [1 ]
Zhang, Tengda [1 ]
Yang, Lei [1 ]
Zhang, Yuzhong [1 ]
Lu, Rongsheng [1 ]
Xie, Xinglong [2 ]
机构
[1] Hefei Univ Technol, Sch Instrument Sci & Optoelect Engn, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Key Lab High Power Laser & Phys, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
line confocal imaging; dark -field imaging; bulk defects detection; OPTICS; DAMAGE;
D O I
10.3788/COL202321.041203
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fabrication of high-quality optics puts a strong demand on high-throughput detection of macroscopic bulk defects in optical components. A dark-field line confocal imaging method is proposed with two distinct advantages: (i) a point-to-line confocal scheme formed by a columnar elliptical mirror and an optical fiber bundle breaks through the constraint on light collection angle and field of view in the traditional line confocal microscopy using an objective, allowing for an extended confocal line field of more than 100 mm while maintaining a light collection angle of 27 degrees; (ii) the bulk defects are independently illuminated as a function of time to eliminate the cross talk in the direction of the confocal slit, thus preserving point confocality and showing the optical section thicknesses to be 162 mu m in the axial direction, and 19 and 22 mu m in the orthogonal transverse directions. The experimental results verify that the method has a minimum detectable bulk defect of less than 5 mu m and an imaging efficiency of 400 mm(2)/s. The method shows great potential in high-throughput and highsensitivity bulk defects detection.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] DARK-FIELD IMAGING OF SUPERCOILED DNA
    DING, MX
    LIANG, FX
    CHEN, F
    ZHAI, ZH
    ZHANG, CG
    GAI, XZ
    CHINESE SCIENCE BULLETIN, 1993, 38 (03): : 239 - 241
  • [22] Dark-field Imaging of Supercoiled DNA
    丁明孝
    梁凤霞
    陈枫
    翟中和
    张存珪
    盖秀贞
    Chinese Science Bulletin, 1993, (03) : 239 - 241
  • [23] A Neutron Dark-field Imaging Experiment with a Neutron Grating Interferometer at a Thermal Neutron Beam Line at HANARO
    Lee, Seung Wook
    Jun, Young Kwon
    Kwon, Oh Yeoul
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (04) : 730 - 734
  • [24] Nonlinear Dark-Field Imaging of One-Dimensional Defects in Monolayer Dichalcogenides
    Carvalho, Bruno R.
    Wang, Yuanxi
    Fujisawa, Kazunori
    Zhang, Tianyi
    Kahn, Ethan
    Bilgin, Ismail
    Ajayan, Pulickel M.
    de Paula, Ana M.
    Pimenta, Marcos A.
    Kar, Swastik
    Crespi, Vincent H.
    Terrones, Mauricio
    Malard, Leandro M.
    NANO LETTERS, 2020, 20 (01) : 284 - 291
  • [25] CONFOCAL FILTERING OF THE INSTANTANEOUS IMAGE IN SCANNED DARK-FIELD ALIGNMENT
    ROSENBLUTH, AE
    PROGLER, C
    FULLENBAUM, M
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1993, 11 (06): : 2183 - 2190
  • [26] Phase-Contrast and Dark-Field Imaging
    Zabler, Simon
    JOURNAL OF IMAGING, 2018, 4 (10):
  • [27] Terahertz dark-field imaging of biomedical tissue
    Löffler, T
    Bauer, T
    Siebert, KJ
    Roskos, HG
    Fitzgerald, A
    Czasch, S
    OPTICS EXPRESS, 2001, 9 (12): : 616 - 621
  • [28] Dark-field third-harmonic imaging
    Doronina-Amitonova, L. V.
    Lanin, A. A.
    Fedotov, I. V.
    Ivashkina, O. I.
    Zots, M. A.
    Fedotov, A. B.
    Anokhin, K. V.
    Zheltikov, A. M.
    APPLIED PHYSICS LETTERS, 2013, 103 (09)
  • [29] Actinic detection of multilayer defects on EUV mask blanks using LPP light source and dark-field imaging
    Tezuka, Y
    Ito, M
    Terasawa, T
    Tomie, T
    EMERGING LITHOGRAPHIC TECHNOLOGIES VIII, 2004, 5374 : 271 - 280
  • [30] Effect of half-stop lateral misalignment on imaging of dark-field and stereoscopic confocal microscopes
    Torok, P
    Laczik, Z
    Sheppard, CJR
    APPLIED OPTICS, 1996, 35 (34): : 6732 - 6739