Fiber SPR biosensor sensitized by MOFs for MUC1 protein detection

被引:19
|
作者
Wang, Rui [1 ]
Liu, Chunlan [1 ]
Wei, Yong [1 ]
Ran, Ze [1 ]
Jiang, Tianci [1 ]
Liu, Chunbiao [1 ]
Shi, Chen [1 ]
Ren, Zhuo [1 ]
Wang, Xingkai [1 ]
Liu, Zhihai [2 ]
Zhang, Yu [2 ]
机构
[1] Chongqing Three Gorges Univ, Coll Elect & Informat Engn, Chongqing 404100, Peoples R China
[2] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber SPR sensor; MUC1; MOFs; Aptamer; NANOCOMPOSITES; MUCIN1;
D O I
10.1016/j.talanta.2023.124467
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concentration of tumor markers is low, which needs a highly sensitive, stable and fast detection method. In this paper, we proposed and demonstrated a U-shape fiber SPR biosensor sensitized by MOFs materials. The surface of the U-shape SPR sensor was modified with MOFs materials to enhance the sensitivity, and the nucleic acid aptamer was immobilized on the sensor surface because of the biocompatibility of MOFs materials. By the high specificity of the nucleic acid aptamer, the MUC1 protein was recognized and detected. The testing results indicate that the sensor has a logarithmic linear response in the MUC1 protein concentration detection range of 1 pg/ml-100 mu g/ml, its sensitivity and detection limit are 5.33 nm/log(mu g/ml) and 0.16 pg/ml respectively. After being sensitized by MOFs, the detection sensitivity of the sensor can be increased by 1.62 times,the LOD can be decreased by 0.75 times. The sensor has high sensitivity and specificity, which has broad application prospects in clinical detection of tumor markers.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Immunogenicity of the hydrophilic region of the MUC1 mucin protein core
    Price, MR
    Petrakou, E
    Sekowski, M
    Murray, A
    ONCOLOGY REPORTS, 1997, 4 (02) : 337 - 339
  • [22] THE IMMUNOGENICITY OF MUC1 PEPTIDES AND MANNAN FUSION PROTEIN (MFP)
    MCKENZIE, IFC
    APOSTOLOPOULOS, V
    XING, XP
    LOVELAND, BE
    PIETERSZ, GA
    JOURNAL OF CELLULAR BIOCHEMISTRY, 1995, : 173 - 173
  • [23] MUC1 MARKER FOR THE DETECTION OF OVARIAN CANCER. A REVIEW
    Florea, Anca
    Cristea, Cecilia
    Sandulescu, Robert
    FARMACIA, 2014, 62 (01) : 1 - 13
  • [24] The other face of MUC1 protein in cancer progression - the role of MUC1-C subunit
    Kmiecik, Alicja M.
    Dziegiel, Piotr
    Ugorski, Maciej
    POSTEPY HIGIENY I MEDYCYNY DOSWIADCZALNEJ, 2019, 73 : 20 - 31
  • [25] Optical fiber SPR biosensor with sandwich assay for the detection of prostate specific antigen
    Jang, Hyun Soo
    Park, Kwang No
    Kang, Chang Duk
    Kim, Jun Pyo
    Sim, Sang Jun
    Lee, Kyung Shik
    OPTICS COMMUNICATIONS, 2009, 282 (14) : 2827 - 2830
  • [26] Highly sensitive electrochemical biosensor for MUC1 detection based on DNA-functionalized CdTe quantum dots as signal enhancers
    Wang, JiaJia
    Kan, Chun
    Jin, Baokang
    ANALYTICAL METHODS, 2024, 16 (45) : 7806 - 7815
  • [27] Detection of MUC1 protein on tumor cells and their derived exosomes for breast cancer surveillance with an electrochemiluminescence aptasensor
    Li, Rui
    An, Yu
    Jin, Tongyu
    Zhang, Fan
    He, Pingang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 882
  • [28] Tissue and serum MUC1 mucin detection in breast cancer patients
    Croce, MV
    Isla-Larrain, MT
    Demichelis, SO
    Gori, JR
    Price, MR
    Segal-Eiras, A
    BREAST CANCER RESEARCH AND TREATMENT, 2003, 81 (03) : 195 - 207
  • [29] Tissue and Serum MUC1 Mucin Detection in Breast Cancer Patients
    María V. Croce
    Marina T. Isla-Larrain
    Sandra O. Demichelis
    Amada Segal-Eiras
    Jorge R. Gori
    Mike R. Price
    Breast Cancer Research and Treatment, 2003, 81 : 195 - 207
  • [30] Aptamer-based Biosensor Developed to Monitor MUC1 Released by Prostate Cancer Cells
    Karpik, Agnieszka E.
    Crulhas, Bruno P.
    Rodrigues, Carolina B.
    Castro, Gustavo R.
    Pedrosa, Valber A.
    ELECTROANALYSIS, 2017, 29 (10) : 2246 - 2253