PAE planning: Radiation exposure and image quality of CT and CBCT

被引:0
|
作者
Steiniger, Beatrice [1 ]
Fiebich, Martin [2 ]
Grimm, Marc-Oliver [3 ]
Malouhi, Amer [1 ]
Reichenbach, Jurgen R. [4 ]
Scheithauer, Marcel [5 ]
Teichgraeber, Ulf
Franiel, Tobias [1 ]
机构
[1] Univ Hosp, Dept Diagnost & Intervent Radiol, Klinikum 1, D-07747 Jena, Germany
[2] TH Mittelhessen, Dept LSE, Wiesenstr 14, D-35390 Giessen, Germany
[3] Univ Hosp, Clin Urol, Klinikum 1, D-07747 Jena, Germany
[4] Univ Hosp, Dept Diagnost & Intervent Radiol, Med Phys Grp, Klinikum 1, D-07747 Jena, Germany
[5] Univ Hosp, Stabsstelle Strahlenschutz, Klinikum 1, D-07747 Jena, Germany
关键词
Prostatic hyperplasia; Therapeutic embolizations; Computed tomography; Cone beam computed tomography; Radiation exposure; PROSTATIC ARTERY EMBOLIZATION;
D O I
10.1016/j.ejrad.2024.111329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine accurate organ doses, effective doses, and image quality of computed tomography (CT) compared with cone beam CT (CBCT) for correct identification of prostatic arteries. Method: A dual-energy CT scanner and a flat-panel angiography system were used. Dose measurements (gallbladder (g), intestine (i), bladder (b), prostate (p), testes (t), active bone marrow of pelvis (bmp) and femura (bmf)) were performed using an anthropomorphic phantom with 65 thermoluminescent dosimeters in the pelvis and abdomen region. For the calculation of the contrast-to-noise ratio (CNR) of the pelvic arteries, a patient whose weight and height were almost identical to those of the phantom was selected for each examination type. Results: The effective dose of CT was 2.7 mSv and that of CBCT was 21.8 mSv. Phantom organ doses were lower for CT than for CBCT in all organs except the testes (g: 1.2 mGy vs. 3.3 mGy, i: 5.8 mGy vs. 23.9 mGy, b: 6.9 mGy vs. 19.4 mGy, p: 6.4 mGy vs. 13.2 mGy, t: 4.7 mGy vs. 2.4 mGy, bmp: 5.1 mGy vs. 18.2 mGy, bmf: 3.3 mGy vs. 6.6 mGy). For human pelvic arteries, the CNR of CT was better than that of CBCT, with the exception of one prostate artery that showed stenosis on CT. Evaluation by experienced radiologists also confirmed the better detectability of prostate arteries on CT examination. Conclusions: In our study preprocedural CT had lower organ doses and better image quality comparedd with CBCT and should be considered for the correct identification of prostatic arteries.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Image Quality and Radiation Exposure in Abdominal Angiography
    Werncke, Thomas
    Becker, Lena S.
    Maschke, Sabine K.
    Hinrichs, Jan B.
    Meine, Timo C. H.
    Dewald, Cornelia L. A.
    Bruesch, Inga
    Rumpel, Regina
    Wacker, Frank K.
    Meyer, Bernhard C.
    INVESTIGATIVE RADIOLOGY, 2024, 59 (10) : 711 - 718
  • [22] Effect of Collimation on Radiation Exposure and Image Quality
    Ghobadifar, Mohamed Amin
    Zarei, Safar
    KOREAN JOURNAL OF PAIN, 2013, 26 (03): : 307 - 308
  • [23] Importance of Collimation for Image Quality and Radiation Exposure
    Toussaint, Kaolane
    Khan, Tommy
    Velez, Kerly Cedeno
    Alicea, Christopher
    RADIOLOGIC TECHNOLOGY, 2023, 94 (03) : 206 - 207
  • [24] Tradeoffs in CT image quality and radiation dose
    McNitt-Gray, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1410 - 1410
  • [25] Principles of CT: Radiation Dose and Image Quality
    Goldman, Lee W.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (04) : 213 - 225
  • [26] Tradeoffs in image quality and radiation dose for CT
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2154 - 2155
  • [27] RADIATION-LEVELS OF MACRORADIOGRAPHY - RADIATION EXPOSURE AND IMAGE QUALITY
    TAKAHASH.S
    SAKUMA, S
    AYAKAWA, Y
    MAEKOSHI, H
    OHARA, K
    RADIOLOGY, 1974, 112 (03) : 709 - 713
  • [28] Image Quality and Radiation Exposure in Pediatric Cardiovascular CT Angiography From Different Injection Sites
    Yang, Ming
    Mo, Xu-Ming
    Jin, Ji-Yang
    Zhang, Jian
    Liu, Bin
    Wu, Min
    Teng, Gao-Jun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) : W117 - W122
  • [29] Outpatient facility dedicated to preparation for ct coronary angiography: impact on image quality and radiation exposure
    Slavich, G. A.
    Piccoli, G.
    Puppato, M.
    Grillone, S.
    Gasparini, D.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A108 - A108
  • [30] Effects of Dual-Energy Technique on Radiation Exposure and Image Quality in Pediatric Body CT
    Siegel, Marilyn J.
    Curtis, Will A.
    Ramirez-Giraldo, Juan C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (04) : 826 - 835