The Effect of Wind Direction on the Cooling Capacity of Short Dry Natural Draft Cooling Towers Operating in Close Proximity

被引:0
|
作者
Khamooshi, Mehrdad [1 ]
Anderson, Timothy [2 ]
Nates, Roy
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Melbourne 3204, Australia
[2] Western Inst Technol Taranaki, Sch Engn Energy & Infrastructure, New Plymouth 4310, New Zealand
关键词
cooling; heat transfer; thermal power; HEAT-TRANSFER CHARACTERISTICS; NUMERICAL-SIMULATION; PERFORMANCE IMPROVEMENT; CROSSWIND; FLOW; SYSTEM; ENHANCEMENT; RADIATORS;
D O I
10.1115/1.4063333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The layout of multiple natural draft dry cooling towers could have a significant influence on the performance of the cooling system in concentrated solar power (CSP) plants; however, this has never been quantified. Hence, this work used computational fluid dynamics (CFD) modeling to analyze the cooling capacity of two short natural draft dry cooling towers (NDDCTs) on a common site for a range of tower spacings, wind-speeds, and wind incidence angles. The results show that the cooling performance of the towers is a strong function of tower spacing and their orientation with respect to the wind direction. It was found that when the wind came at a 90-deg wind incidence angle (i.e., normal to a line drawn between the two towers), their cooling capacity was improved at tower spacings of less than 1.8 tower diameters (1.8D), though for the other tower spacings, there was no interaction between the towers. However, with the wind at 45 deg to the towers, the flow around the towers resulted in a decrease in their cooling capacity at tower spacings of 1.8D and 2.6D. Most interestingly, it was found that orienting the towers in line with the prevailing wind direction delivered improvements in the cooling capacity of up to 30%. This is due to the windward tower acting as a passive windbreak. Hence, as CSP plant capacity is increased, and additional cooling towers are required, these should be placed close to any existing tower and oriented along the line of the prevailing winds.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] The performance of natural draft dry cooling towers under crosswind: CFD study
    Al-Waked, R
    Behnia, M
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) : 147 - 161
  • [22] MINIMUM SIZE OF LARGE DRY COOLING TOWERS WITH COMBINED MECHANICAL AND NATURAL DRAFT
    MOORE, FK
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1973, 95 (03): : 383 - 389
  • [23] Improving the efficiency of natural draft cooling towers
    Smrekar, J
    Oman, J
    Sirok, B
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (9-10) : 1086 - 1100
  • [24] NATURAL DRAFT COOLING TOWERS AND THEIR INFLUENCE ON ENVIRONMENT
    MIKYSKA, L
    BRENNSTOFF-WARME-KRAFT, 1973, 25 (02): : 48 - 51
  • [25] Design of large Natural Draft Cooling Towers
    Kraetzig, Wilfried B.
    Andres, Matthias
    Arntz, Matthias
    Eckstein, Ulrich
    Harte, Reinhard
    Woermann, Ralf
    BAUTECHNIK, 2016, 93 (03) : 151 - 161
  • [26] Effect of Thermal Storage Layer Shape on Cooling Performance of Solar-Enhanced Natural-Draft Dry Cooling Towers
    He S.
    Wang R.
    Zhang Z.
    Yan M.
    Liu Y.
    Gao M.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (04): : 405 - 410
  • [27] THE INLET AIR PRE-COOLING OF NATURAL DRAFT DRY COOLING TOWERS-WETTED MEDIUM ISSUE
    He, Suoying
    Zhang, Guanhong
    Xu, Yi
    Sun, Fengzhong
    PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 1, 2017,
  • [28] Water spray for pre-cooling of inlet air for Natural Draft Dry Cooling Towers - Experimental study
    Alkhedhair, Abdullah
    Guan, Zhiqiang
    Jahn, Ingo
    Gurgenci, Hal
    He, Suoying
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 90 : 70 - 78
  • [29] A numerical study on interactions between three short natural draft dry cooling towers In an in-line arrangement
    Khamooshi, Mehrdad
    Anderson, Timothy N.
    Nates, Roy J.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 159
  • [30] Numerical simulation of water spray for pre-cooling of inlet air in natural draft dry cooling towers
    Alkhedhair, Abdullah
    Gurgenci, Hal
    Jahn, Ingo
    Guan, Zhiqiang
    He, Suoying
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 416 - 424