Optimization of window solar gain for a building with less cooling load

被引:6
|
作者
Mustafa, Jawed [1 ]
Alqaed, Saeed [1 ]
Sharifpur, Mohsen [2 ,3 ]
Meyer, Josua [4 ]
机构
[1] Najran Univ, Coll Engn, Mech Engn Dept, POB 1988, Najran 61441, Saudi Arabia
[2] Univ Pretoria, Dept Mech & Aeronaut Engn, Pretoria, South Africa
[3] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[4] Stellenbosch Univ, Dept Mech & Mechatron Engn, Stellenbosch, South Africa
关键词
Building energy demand; Optimization; Shadow; Solar radiation; PERFORMANCE; SHUTTER;
D O I
10.1016/j.csite.2023.103890
中图分类号
O414.1 [热力学];
学科分类号
摘要
Considering solar gain through the window (SGW), this study investigated the effects of installing shading on cooling load. Approving energy analysis for the base building (without shading), the cooling, heating, and annual energy demand were calculated. The best window angle and the best shading projection were obtained using the genetic algorithm. For the yearly minimum energy demand scenario, it was found that the window should be placed in the south direction, accompanied by the shading project with a maximum length of 20 cm. The results of the genetic algorithm revealed that for windows at the angle of 75-90 degrees, the positive shading effects on annual energy demand become maximum. In this case, the shading reduces the yearly energy consumption by 3.1 %. The optimization showed that the shades have the best results for reducing the cold load for windows that are located in the azimuth angle between 135 and 180 degrees.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Installation of roof-top solar PV modules and their impact on building cooling load
    Kotak, Y.
    Gago, E. J.
    Mohanty, P.
    Muneer, T.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (06): : 613 - 633
  • [22] DETERMINING WINDOW SOLAR HEAT GAIN COEFFICIENT
    HARRISON, SJ
    VANWONDEREN, SJ
    ASHRAE JOURNAL, 1994, 36 (08) : 26 - 32
  • [23] Air-conditioning for a window-less building
    Roedler, F
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1937, 81 : 1281 - 1281
  • [24] Influence of occupancy-oriented interior cooling load on building cooling load design
    Ding, Yan
    Wang, Zhaoxia
    Feng, Wei
    Marnay, Chris
    Zhou, Nan
    APPLIED THERMAL ENGINEERING, 2016, 96 : 411 - 420
  • [25] Analysis of a hybrid solar window for building integration
    Ulavi, Tejas
    Hebrink, Tim
    Davidson, Jane H.
    SOLAR ENERGY, 2014, 105 : 290 - 302
  • [26] Analysis of a Hybrid Solar Window for Building Integration
    Ulavi, Tejas
    Hebrink, Tim
    Davidson, Jane H.
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 1941 - +
  • [27] Analysis of heat gain decrease achieved by ventilation heat recovery in solar cooling building: case study
    Gil, Bartosz
    Rosiek, Sabina
    Kasperski, Jacek
    Nems, Magdalena
    Nems, Artur
    Batlles, Francisco J.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 2521 - 2528
  • [28] Cooling Load Distribution of Large Space Building
    陈红兵
    涂光备
    杨洁
    Chan K T
    Transactions of Tianjin University, 2003, (04) : 340 - 344
  • [29] Building Cooling load prediction based on LightGBM
    Zhao, RuoChen
    Wei, Dong
    Ran, YiBing
    Zhou, Guang
    Jia, YuChen
    Zhu, ShiLun
    He, YouQuan
    IFAC PAPERSONLINE, 2022, 55 (11): : 114 - 119
  • [30] Particle Swarm Optimization-based LS-SVM for Building Cooling Load Prediction
    Li Xuemei
    Shao Ming
    Ding Lixing
    Xu Gang
    Li Jibin
    JOURNAL OF COMPUTERS, 2010, 5 (04) : 614 - 621