A Novel Method for Evaluating Early Tumor Response Based on Daily CBCT Images for Lung SBRT

被引:0
|
作者
Luo, Wei [1 ]
Xiu, Zijian [1 ]
Wang, Xiaoqin [2 ]
Mcgarry, Ronald [1 ]
Allen, Joshua [3 ]
机构
[1] Univ Kentucky, Dept Radiat Med, 800 Rose St, Lexington, KY 40536 USA
[2] Univ Kentucky, Dept Radiol, 800 Rose St, Lexington, KY 40536 USA
[3] AdventHlth, 2501 N Orange Ave, Orlando, FL 32804 USA
关键词
tumor response assessment; stereotactic radiation therapy (SBRT); cone-beam computerized tomography (CBCT); tumor area; tumor linear attenuation coefficient (mu); tumor contrast-to-noise ratio (CNR); RADIATION-THERAPY; CANCER; RADIOTHERAPY; REGRESSION;
D O I
10.3390/cancers16010020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: We aimed to develop a new tumor response assessment method for lung SBRT. Methods: In total, 132 lung cancer patients with 134 tumors who received SBRT treatment with daily CBCT were included in this study. The information about tumor size (area), contrast (contrast-to-noise ratio (CNR)), and density/attenuation (mu) was derived from the CBCT images for the first and the last fractions. The ratios of tumor area, CNR, and mu (R-A, R-CNR, R-mu) between the last and first fractions were calculated for comparison. The product of the three rations was defined as a new parameter (R) for assessment. Tumor response was independently assessed by a radiologist based on a comprehensive analysis of the CBCT images. Results: R ranged from 0.27 to 1.67 with a mean value of 0.95. Based on the radiologic assessment results, a receiver operation characteristic (ROC) curve with the area under the curve (AUC) of 95% was obtained and the optimal cutoff value (R-C) was determined as 1.1. The results based on R-C achieved a 94% accuracy, 94% specificity, and 90% sensitivity. Conclusion: The results show that R was correlated with early tumor response to lung SBRT and that using R for evaluating tumor response to SBRT would be viable and efficient.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] CBCT in Lung FFF-SABR: predictive parameters of early response
    Alongi, F.
    Mazzola, R.
    Ricchetti, F.
    Levra, N. Giaj
    Fersino, S.
    Sicignano, G.
    Fiorentino, A.
    Ruggieri, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S571 - S571
  • [22] CBCT Radiomics May Predict Short-Term SBRT Effect in Early Stage Lung Cancer Patients
    Hou, L.
    Zhou, C.
    Xu, Y.
    Meng, Y.
    Yu, C.
    Kong, F.
    Yang, H.
    JOURNAL OF THORACIC ONCOLOGY, 2019, 14 (10) : S1097 - S1097
  • [23] Evaluation of Tumor Volume and Electron Density Changes on CBCT Images in Lung Cancer Patients
    Kara, E.
    Ozdemir, O.
    Hicsonmez, A.
    Zorlu, F.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S889 - S890
  • [24] A Novel Autosegmentation Method for Lung Tumor on 18F-FDG PET images
    Feng, Y.
    Ming, X.
    Zhang, Y.
    Wang, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S110 - S110
  • [25] Daily dose calculation using CBCT images can trigger treatment adaptation for lung cancer patients
    Hoffmann, L.
    Khalil, A. A.
    Knap, M. M.
    Elstrom, U. V.
    Kaplan, L. P.
    Moller, D. S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1129 - S1130
  • [26] Impact of EGFR Mutational Status on Interfractional SBRT Lung Oligometastatic Tumor Response
    Zhou, Y.
    Tolekidis, G.
    Ngyuen, A.
    Fidler, M.
    Batus, M.
    Bonomi, P.
    Marwaha, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E299 - E300
  • [27] A NOVEL METHOD OF EVALUATING TRANSIENT RESPONSE
    LIOU, ML
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1966, 54 (01): : 20 - &
  • [28] Evaluation of Accuracy for Target Margin Size Obtained From CBCT On Lung SBRT Based On Film Dosimetry
    Lee, S.
    Park, J.
    Park, S.
    Lee, M.
    Kim, M.
    Suh, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 259 - 259
  • [29] Automated Estimation of Lung Tumor Locations for Tumor-Based Patient Setup Using MV-CBCT Images in Stereotactic Body Radiotherapy
    Yoshidome, S.
    Arimura, H.
    Nakamura, K.
    Shioyama, Y.
    Atsumi, K.
    Yoshikawa, H.
    Nishikawa, K.
    Hirata, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Removal of Motion Artifacts in CBCT of Lung Tumors Based on Tracked Tumor Motion during CBCT Acquisition
    Lewis, J. H.
    Li, R.
    Jia, X.
    Watkins, W. T.
    Song, W. Y.
    Jiang, S. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S676 - S677