A Unified Open-Circuit Fault Diagnosis and Condition Monitoring Method for Three-Level T-Type Inverter

被引:7
|
作者
Zhang, Weiwei [1 ]
He, Yigang [1 ]
Chen, Jianfei [1 ]
Du, Bolun [2 ]
机构
[1] Wuhan Univ, Wuhan 430072, Peoples R China
[2] China Elect Power Res Inst, Wuhan 430000, Peoples R China
基金
中国国家自然科学基金;
关键词
Condition monitoring (CM); fault diagnosis (FD); ON-state voltage (OV); open-circuit (OC) fault; three-level T-type (3L-T) inverter; POWER-ELECTRONIC CONVERTERS; ACCURATE MEASUREMENT; RELIABILITY; TIME; RESISTANCE; FREQUENCY; MODULE;
D O I
10.1109/TPEL.2022.3232996
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional fault diagnosis (FD) and condition monitoring (CM) methods for three-level T-type (3L-T) inverters are studied separately, which is not conducive to guaranteeing the reliability of the 3L-T inverter in an all-around way. This article presents a unified open-circuit FD and CM method for the 3L-T inverter based on the proposed on-state voltage measurement circuit (OVMC). The designed OVMC comprises a voltage limiter, an absolute value circuit, and a minimum value circuit, separating all the OVs and actual switching state information with a few devices and terminals. The corresponding sampling method is designed under the space vector pulsewidth modulation mode, and the sampling frequency is only twice the switching frequency. Three exceptional cases are considered during the implementation to achieve accurate OV sampling. The proposed method for fault locating requires only a straightforward lookup table without complicated feature extraction and threshold setting steps. Meanwhile, the FD results would help to correct the OV distribution. Experimental results demonstrate that the proposed unified FD and CM method merits high measurement accuracy, fast response speed, and short FD time.
引用
收藏
页码:5376 / 5391
页数:16
相关论文
共 50 条
  • [41] Hybrid Modulation Strategy With Neutral Point Potential Balance of T-Type Three-Level Converter Under Switch Open-Circuit Fault
    Guan, Bo
    Liu, Zhenhua
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (11) : 10797 - 10806
  • [42] Analysis and Simulation of Neutral Point Potential Oscillation Characteristic of T-type Three-level Converter under Switch Open-circuit Fault
    Guan, Bo
    Du, Xiong
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 1603 - 1608
  • [43] Hybrid Modulation Strategy With Neutral Point Potential Balance of T-Type Three-Level Converter Under Switch Open-Circuit Fault
    Guan, Bo
    Liu, Zhenhua
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2021, : 10797 - 10806
  • [44] Fault Diagnosis and Tolerant Control for Three-Level T-Type Inverters
    Chao, Kuei-Hsiang
    Chang, Long-Yi
    Hung, Chien-Chun
    ELECTRONICS, 2022, 11 (16)
  • [45] NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest
    Liu, Shiyuan
    Qian, Xu
    Wan, Hong
    Ye, Zongbin
    Wu, Shoupeng
    Ren, Xiaohong
    JOURNAL OF SENSORS, 2020, 2020
  • [46] A Rapid Model Prediction Control Method for T-Type Three-Level Inverter
    Wang, Guobin
    Zhang, Li
    Wang, Zhiguo
    Yin, Xia
    2023 7TH INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS, ICGEA, 2023, : 142 - 146
  • [47] A HYBRID MODEL/DATA-DRIVEN METHOD FOR OPEN-CIRCUIT FAULT DIAGNOSIS IN NPC THREE-LEVEL INVERTERS
    Yang, Weilin
    Zhang, Chao
    Xu, Dezhi
    Ye, Yujian
    International Journal of Innovative Computing, Information and Control, 2025, 21 (02):
  • [48] An Online Open-Circuit Fault Diagnosis Technique for Three-Level Inverter-Fed Six-Phase PMSM Drives
    Das, Partha Pratim
    Satpathy, Subhransu
    Bhattacharya, Subhashish
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (11) : 14974 - 14987
  • [49] A Redundant Unit to Form T-Type Three-Level Inverters Tolerant of IGBT Open-Circuit Faults in Multiple Legs
    Wang, Borong
    Li, Zhan
    Bai, Zhihong
    Krein, Philip T.
    Ma, Hao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (01) : 924 - 939
  • [50] Detection Method of an Open-Switch Fault and Fault-Tolerant Strategy for a Grid-Connected T-Type Three-Level Inverter System
    Choi, Ui-Min
    Lee, Kyo-Beum
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 4188 - 4195