The effect of balloon-expandable stent and self-expanding stent on changes in mitral annular motion after aortic valve replacement in patients with aortic stenosis

被引:1
|
作者
Hori, Daijiro [1 ]
Nomura, Yohei [1 ]
Taniguchi, Yosuke [2 ]
Yuri, Koichi [1 ]
Mieno, Makiko [3 ]
Kimura, Naoyuki [1 ]
Yamaguchi, Atsushi [1 ]
机构
[1] Jichi Med Univ, Saitama Med Ctr, Dept Cardiovasc Surg, Saitama, Japan
[2] Jichi Med Univ, Saitama Med Ctr, Div Cardiol, Saitama, Japan
[3] Jichi Med Univ, Ctr Informat, Dept Med Informat, Shimotsuke, Tochigi, Japan
关键词
Intuity; Perceval; TAVR; E'; Mitral annular motion; EUROPEAN ASSOCIATION; SOCIETY; DISEASE;
D O I
10.1007/s10047-023-01384-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
ObjectivesThe purpose of this study was to evaluate the effect of decalcification and existence of stent at the aortic annulus on mitral annular motion after surgery.MethodsPatients receiving Inspiris (Edwards, CA, USA, n = 117), Intuity (Edwards, n = 36), Perceval (Corcym, London, UK, n = 36), Evolut (Medtronics, MN, USA, n = 81) and Sapien 3 (Edwards, n = 250) were included in the study. Mitral annular motion was evaluated by E', using tissue doppler imaging.ResultsAfter surgery, a significant increase in E' was observed in patients receiving Inspiris (Before: 4.2 +/- 1.21 cm/s vs. Discharge: 5.0 +/- 1.23 cm/s, p < 0.001). Mid-term echocardiogram performed at 11.8 +/- 2.2 months after the surgery, showed a significant increase in E' in patients receiving Inspiris (Before: 4.2 +/- 1.21 cm/s vs. Mid-term: 5.2 +/- 1.20 cm/s, p < 0.001) and Perceval (Before: 3.9 +/- 1.34 cm/s vs. Mid-term: 4.5 +/- 1.24 cm/s, p = 0.008). Univariable analysis showed a higher increase in E' in patients with decalcified annulus compared to those without decalcified annulus (Decalcification: 0.15 +/- 1.321 cm/s vs. No Decalcification: 0.66 +/- 1.420 cm/s, p < 0.001). Multivariable analysis showed that balloon-expandable stent (beta = - 0.6960, p < 0.001) and self-expanding stent (r = - 0.3592, p = 0.042) were independent limiting factors for an increase in E' at discharge. However, balloon-expandable stent (beta = - 0.8382, p < 0.001), and not self-expanding stent (beta = - 0.3682, p = 0.089), was a remaining independent factor associated with E' at mid-term follow-up.ConclusionsDecalcification was associated with improvement in E' after surgery. Balloon-expandable stent was an independent limiting factor for improvement in E' up to 1 year after the surgery, while self-expanding stent was not a significant factor after 1 year.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [31] Pathology of Balloon-Expandable and Self-Expanding Stents Following MRI-Guided Transapical Aortic Valve Replacement
    Kindzelski, Bogdan A.
    Li, Ming
    Mazilu, Dumitru
    Horvath, Keith A.
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (02): : 139 - 147
  • [32] The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation
    Gonska, Birgid
    Seeger, Julia
    Baarts, Justus
    Rodewald, Christoph
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    JOURNAL OF CARDIOLOGY, 2017, 69 (5-6) : 877 - 882
  • [33] Effect of balloon-expandable and self-expanding stent fixation on endoluminal polytetrafluoroethylene graft healing
    Ombrellaro, MP
    Stevens, SL
    Sciarrotta, J
    Schaeffer, DO
    Freeman, MB
    Goldman, MH
    AMERICAN JOURNAL OF SURGERY, 1997, 173 (06): : 461 - 466
  • [34] Comparable efficacy and safety for bicuspid aortic valve stenosis patients undergoing transcatheter aortic valve replacement with balloon-expandable or self-expanding valves using Wei's sizing method
    Lee, Yung-Tsai
    Yin, Wei-Hsian
    Tsao, Tien-Ping
    Lee, Kuo-Chen
    Lin, Huan-Chiu
    Liu, Chun-Ting
    Hsiung, Ming-Chon
    Wei, Jeng
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2024, 87 (11) : 993 - 1001
  • [35] Long-Term Clinical Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expanding Valves
    Khambhati, Jay
    Almarzooq, Zaid
    Patel, Parth
    Hulme, Olivia
    Sevilla-Cazes, Jonathan
    Khan, Sahoor
    Song, Yang
    Al-Roub, Nora
    Shah, Pinak
    Majithia, Arjun
    Dani, Sourbha
    Baron, Suzanne
    Yeh, Robert
    Elmariah, Sammy
    Kolte, Dhaval
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B167 - B167
  • [36] 5-Year Outcomes With Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients With Small Annuli
    Okuno, Taishi
    Tomii, Daijiro
    Lanz, Jonas
    Heg, Dik
    Praz, Fabien
    Stortecky, Stefan
    Reineke, David
    Windecker, Stephan
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : 429 - 440
  • [37] Percutaneous aortic valve replacement with a self-expanding stent - First animal results
    Ferrari, M
    Hellige, G
    Schlosser, M
    Lang, K
    Frerichs, I
    Mueller, E
    Eisold, G
    Figulla, HR
    EUROPEAN HEART JOURNAL, 2002, 23 : 156 - 156
  • [38] Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
    Lanz, Jonas
    Kim, Won-Keun
    Walther, Thomas
    Burgdorf, Christof
    Mollmann, Helge
    Linke, Axel
    Redwood, Simon
    Thilo, Christian
    Hilker, Michael
    Joner, Michael
    Thiele, Holger
    Conzelmann, Lars
    Conradi, Lenard
    Kerber, Sebastian
    Schymik, Gerhard
    Prendergast, Bernard
    Husser, Oliver
    Stortecky, Stefan
    Heg, Dik
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    LANCET, 2019, 394 (10209): : 1619 - 1628
  • [39] Long-Term Structural Valve Deterioration of Balloon-Expandable vs. Self-Expanding Transcatheter Aortic Valve Replacement
    Reddy, P. K.
    Zheng, L.
    Khayat, E.
    Snigur, G.
    Sawant, V.
    Cellamare, M.
    Satler, L.
    Ben-Dor, I.
    Rogers, T.
    Sadeghpour, A.
    Waksman, R.