Determination of chlorophylls a and b and β-carotene in environmental waters: Diminishing wastes and analysis time by in-tube solid-phase microextraction coupled on-line to nano liquid chromatography

被引:3
|
作者
Soto, C. [1 ]
Herraez-Hernandez, R. [1 ]
Campins-Falco, P. [1 ]
机构
[1] Univ Valencia, Dept Quim Analit, MINTOTA Res Grp, Fac Quim, Dr Moliner 50, Burjassot 46100, Valencia, Spain
来源
关键词
Chlorophylls; Carotenoids; Water samples; In-tube solid phase microextraction; Nano liquid chromatography; Time; Low residues; Friendly solvent; IDENTIFICATION; PHYTOPLANKTON; EXTRACTION; TOOL;
D O I
10.1016/j.sampre.2023.100093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chlorophylls and carotenoids are indicators of water quality. A new method based on in-tube solid-phase microextraction (IT-SPME) coupled on-line to nano-liquid chromatography with diode array detection (NanoLCDAD) was developed. This paper aims to provide selectivity and sensitivity with a short analysis time of about 10 min and low residues of friendly solvents, 5 mu L/run of ethanol:water 95:5 and 250 mu L of ethanol for dissolving the pigments retained in a nylon filter (0.45 mu m, 13 mm) from 30 mL of water. IT-SPME capillary was a fused silica capillary (10 cm length x 75 mu m internal diameter, i.d.) with a coating of tetraethyl orthosilicato (TEOS), triethoximethylsilane (MTEOS) doped with SiO2 nanoparticles (NPs) and an analytical column Zorbax 300SB-C18 (50 mm x 75 mu m i.d., 3.5 mu m particle size) was used. The recovery obtained to chlorophyll a, chlorophyll b and beta-carotene were 93 +/- 8 %, 92 +/- 7 % and 94 +/- 4 %, respectively. The method shows good linearity in the range up to 300 mu g L-1 for chlorophyll a and beta-carotene and up to 600 mu g L-1 for chlorophyll b. The achieved limits of detection (LODs) in samples were 0.1 mu g L-1 to chlorophyll a and beta-carotene, and 0.2 mu g L-1 to chlorophyll b. Values of relative standard deviations (RSD) expressed in% between 2 and 3 were obtained. Pigments were successfully determined with a short analysis time and minimal residues in real water samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Development of on-line monolith-based in-tube solid phase microextraction for the sensitive determination of triazoles in environmental waters
    Pang, Jinling
    Mei, Meng
    Yuan, Dongxing
    Huang, Xiaojia
    TALANTA, 2018, 184 : 411 - 417
  • [22] Automated analysis of oseltamivir and oseltamivir carboxylate in environmental waters by online in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry
    Kataoka, Hiroyuki
    Shiba, Haruna
    Saito, Keita
    ANALYTICAL METHODS, 2012, 4 (06) : 1513 - 1518
  • [23] Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Jing-Fang Huang
    Bo Lin
    Qiong-Wei Yu
    Yu-Qi Feng
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1228 - 1235
  • [24] Automated on-line in-tube solid-phase microextraction-assisted derivatization coupled to liquid chromatography for quantifying residual dimethylamine in cationic polymers
    Prieto-Blanco, M. C.
    Chafer-Pericas, C.
    Lopez-Mahia, P.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 118 - 123
  • [25] Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Huang, JF
    Lin, B
    Yu, QW
    Feng, YQ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (05) : 1228 - 1235
  • [26] Analysis of Contact Traces of Cannabis by In-Tube Solid-Phase Microextraction Coupled to Nanoliquid Chromatography
    Jornet-Martinez, Neus
    Ortega-Sierra, Adrian
    Verdu-Andres, Jorge
    Herraez-Hernandez, Rosa
    Campins-Falco, Pilar
    MOLECULES, 2018, 23 (09):
  • [27] Automated on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography for the analysis of bisphenol A, alkylphenols, and phthalate esters in foods contacted with plastics
    Kataoka, Hiroyuki
    Ise, Megumi
    Narimatsu, Shizuo
    Journal of Separation Science, 2002, 25 (1-2) : 77 - 85
  • [28] Automated on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography for the analysis of bisphenol A, alkylphenols, and phthalate esters in foods contacted with plastics
    Kataoka, H
    Ise, M
    Narimatsu, S
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (1-2): : 77 - 85
  • [29] Simultaneous determination of testosterone, cortisol, and dehydroepiandrosterone in saliva by stable isotope dilution on-line in-tube solid-phase microextraction coupled with liquid chromatography–tandem mass spectrometry
    Hiroyuki Kataoka
    Kentaro Ehara
    Rie Yasuhara
    Keita Saito
    Analytical and Bioanalytical Chemistry, 2013, 405 : 331 - 340
  • [30] Automated on-line in-tube solid-phase microextraction coupled with HPLC/MS/MS for the determination of butyrophenone derivatives in human plasma
    Takeshi Kumazawa
    Koichi Saeki
    Isao Yanagisawa
    Seisaku Uchigasaki
    Chika Hasegawa
    Hiroshi Seno
    Osamu Suzuki
    Keizo Sato
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1161 - 1170