Characterization of Flexor Digitorum Superficialis Muscle Stiffness Using Ultrasound Shear Wave Elastography and MyotonPRO: A Cross-Sectional Study Investigating the Correlation between Different Approaches

被引:1
|
作者
Tantipoon, Phongpan [1 ,2 ]
Praditpod, Nuttaporn [2 ]
Pakleppa, Markus [1 ]
Li, Chunhui [1 ]
Huang, Zhihong [1 ]
机构
[1] Univ Dundee, Sch Sci & Engn, Biomed Engn, Dundee DD1 4HN, Scotland
[2] Thammasat Univ, Fac Allied Hlth Sci, Dept Phys Therapy, Bangkok 12120, Thailand
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 11期
关键词
ultrasonography; elastography; diagnostic imaging; elastic modulus; hand muscle; MyotonPRO; MECHANICAL-PROPERTIES; CLINICAL-APPLICATIONS; CUSE; RELIABILITY; PRINCIPLES; INDEX;
D O I
10.3390/app13116384
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Muscle stiffness provides a key insight toward clinical assessment for rehabilitation. Regarding the high-cost and technical skill requirement of ultrasound shear wave elastography (SWE) restricting extensive clinical use, MyotonPRO has been proposed as a complementary tool for muscle stiffness measurement. There is a deficiency of studies revealing the use of this tool for measuring muscle stiffness contributing to hand control. The purpose of this study was to assess the capability and effectiveness of MyotonPRO and SWE for hand muscle stiffness characterization. The stiffness of the dominant flexor digitorum superficialis (FDS) muscle of 25 healthy participants (12 males and 13 females) aged 29.60 +/- 9.81 years was evaluated while they performed grip tasks. The muscle stiffness of males and females was compared. The correlation between dynamic muscle stiffness given by MyotonPRO and Young's modulus obtained from SWE was investigated. Statistical analysis indicated a significant difference in the dynamic muscle stiffness between genders in all conditions (p < 0.05), whereas a significant difference in Young's modulus was found only at the resting state. A moderate correlation was found between dynamic muscle stiffness and Young's modulus (r ranged from 0.243 to 0.489). Therefore, MyotonPRO can be used to assess the muscle stiffness of the FDS muscle at rest and during muscle contraction.
引用
收藏
页数:14
相关论文
共 23 条
  • [21] Methotrexate therapy is not associated with increased liver stiffness and significant liver fibrosis in rheumatoid arthritis patients: A cross-sectional controlled study with real-time two-dimensional shear wave elastography
    Erre, Gian Luca
    Cadoni, Maria Luisa
    Meloni, Pierluigi
    Castagna, Floriana
    Mangoni, Arduino Aleksander
    Piga, Matteo
    Passiu, Giuseppe
    Carru, Ciriaco
    Zinellu, Angelo
    Vidili, Gianpaolo
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2019, 69 : 57 - 63
  • [22] Quantitative shear wave elastography compared to standard ultrasound (qualitative B-mode grayscale sonography and quantitative power Doppler) for evaluation of achillotendinopathy in treatment-naive individuals: A cross-sectional study
    Chen, Lixiu
    Cheng, Ying
    Zhou, Liang
    Zhang, Lei
    Deng, Xueyan
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 31 (08): : 847 - 854
  • [23] Investigating the correlation between hip abductor muscle strength and width in anteroposterior pelvic radiographs in hip revision candidates following previous total hip arthroplasty: a cross-sectional study
    Shafiei, Seyyed Hossein
    Nourbakhsh, Amir Salar
    Siavashi, Babak
    Soleimani, Mohammad
    Talebian, Parham
    ANNALS OF MEDICINE AND SURGERY, 2023, 85 (06): : 2437 - 2442