A pre-column derivatization high-performance liquid chromatography method for simultaneous determination of short-chain and medium-chain fatty acids in a fecal sample

被引:3
|
作者
Fu, Zhibo [1 ]
Zhang, Hongyang [1 ]
Zeng, Zhijun [2 ]
Ning, Fanghong [3 ]
Xu, Ziwei [4 ]
Liu, Chenyu [1 ]
Zhang, Min [5 ]
Hu, Ping [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] Jiangxi Univ Chinese Med, Res Ctr Differentiat & Dev TCM Basic Theory, Jiangxi Prov Key Lab TCM Etiopathogenesis, Nanchang, Jiangxi, Peoples R China
[3] East China Univ Sci & Technol, Sch Biotechnol, Dept Biotechnol, Shanghai, Peoples R China
[4] Jiangxi Univ Chinese Med, Sch Pharm, Dept Pharmacol, Nanchang, Jiangxi, Peoples R China
[5] East China Univ Sci & Technol, Sch Pharm, China Shanghai Key Lab New Drug Design, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
derivatization; feces sample; indole-3-acetic acid hydrazide; high-performance liquid chromatography; ultraviolet detector; QUANTIFICATION; METABOLITES; OBESITY;
D O I
10.1002/jssc.202200671
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Short-chain and medium-chain fatty acids have plentiful biological functions, which play a crucial role in the diagnosis and therapy of many diseases. Herein, a new method for simultaneous quantifying 17 short-chain and medium-chain fatty acids with high-performance liquid chromatography coupled with an ultraviolet detector was developed and the pre-column derivatization by indole-3-acetic acid hydrazide was performed to improve the separation and detection. The conditions of the derivatization reaction were systematically investigated. Subsequently, the method was validated and the results showed a satisfactory linearity (linear regression coefficients > 0.9969), the limit of detection (4.0x10(-3)-1.9x10(-2) mu mol/L), precision (0.9%-7.3% for intra-day and 2.0%-9.8% for inter-day), recovery (90.0%-109.1% with relative standard deviation <7.7%) and stability (0.1%-3.3% for standard solution and 0.2%-3.9% for fecal sample). Finally, the established method was successfully applied to quantify short-chain and medium-chain fatty acids in the feces of healthy control and diabetic rats. Eleven kinds of short-chain and medium-chain fatty acids were detected and six of them showed a significant difference between the control group and the model group.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Determination of Short-chain Fatty Acids in Rat and Human Feces by High-Performance Liquid Chromatography with Electrochemical Detection
    Kotani, Akira
    Miyaguchi, Yuji
    Kohama, Mototaka
    Ohtsuka, Takafumi
    Shiratori, Taisei
    Kusu, Fumiyo
    ANALYTICAL SCIENCES, 2009, 25 (08) : 1007 - 1011
  • [12] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED PRE-COLUMN DERIVATIZATION FOR AMINO-ACIDS
    BUCK, RH
    KRUMMEN, K
    JOURNAL OF CHROMATOGRAPHY, 1984, 303 (01): : 238 - 243
  • [13] A novel pre-column derivatization reaction for the determination of dithiocarbamates in plasma by high-performance liquid chromatography
    Petsch, M
    Seipelt, J
    Mayer-Helm, BX
    ANALYTICA CHIMICA ACTA, 2004, 516 (1-2) : 119 - 124
  • [14] Determination of residual phenylhydrazines in drug substances by high-performance liquid chromatography with pre-column derivatization
    Li, Jiaxin
    Joelle, Eyoro Noah Nadine
    Yang, Qian
    Zheng, Feng
    Liu, Wenyuan
    Liu, Jing
    ANALYTICAL METHODS, 2019, 11 (48) : 6146 - 6152
  • [15] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF CYANIDE IN URINE BY PRE-COLUMN FLUORESCENCE DERIVATIZATION
    SANO, A
    TAKEZAWA, M
    TAKITANI, S
    BIOMEDICAL CHROMATOGRAPHY, 1989, 3 (05) : 209 - 212
  • [16] Determination of clarithromycin in serum by high performance liquid chromatography with pre-column derivatization
    Wei Minji
    Lu Yuan
    Wang Shan
    Zhang Pu
    Liu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 : S168 - S170
  • [17] Determination of sulfur amino acids in feedstuffs by high performance liquid chromatography coupled with pre-column derivatization
    Yu Shuxin
    Feng Si
    Sun Yuanshe
    Tang Tao
    Han Jing
    Wang Fenglin
    Li Tong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (03) : 239 - 243
  • [18] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF SERUM SHORT-CHAIN FATTY-ACIDS BY DIRECT DERIVATIZATION
    MIWA, H
    YAMAMOTO, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (01): : 33 - 41
  • [19] In vivo absorption of medium-chain fatty acids by the rat colon exceeds that of short-chain fatty acids
    Jorgensen, JR
    Fitch, MD
    Mortensen, PB
    Fleming, SE
    GASTROENTEROLOGY, 2001, 120 (05) : 1152 - 1161
  • [20] QUANTIFICATION OF FREE CARNITINE, INDIVIDUAL SHORT-CHAIN AND MEDIUM-CHAIN ACYLCARNITINES, AND TOTAL CARNITINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY