A pre-column derivatization high-performance liquid chromatography method for simultaneous determination of short-chain and medium-chain fatty acids in a fecal sample

被引:3
|
作者
Fu, Zhibo [1 ]
Zhang, Hongyang [1 ]
Zeng, Zhijun [2 ]
Ning, Fanghong [3 ]
Xu, Ziwei [4 ]
Liu, Chenyu [1 ]
Zhang, Min [5 ]
Hu, Ping [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] Jiangxi Univ Chinese Med, Res Ctr Differentiat & Dev TCM Basic Theory, Jiangxi Prov Key Lab TCM Etiopathogenesis, Nanchang, Jiangxi, Peoples R China
[3] East China Univ Sci & Technol, Sch Biotechnol, Dept Biotechnol, Shanghai, Peoples R China
[4] Jiangxi Univ Chinese Med, Sch Pharm, Dept Pharmacol, Nanchang, Jiangxi, Peoples R China
[5] East China Univ Sci & Technol, Sch Pharm, China Shanghai Key Lab New Drug Design, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
derivatization; feces sample; indole-3-acetic acid hydrazide; high-performance liquid chromatography; ultraviolet detector; QUANTIFICATION; METABOLITES; OBESITY;
D O I
10.1002/jssc.202200671
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Short-chain and medium-chain fatty acids have plentiful biological functions, which play a crucial role in the diagnosis and therapy of many diseases. Herein, a new method for simultaneous quantifying 17 short-chain and medium-chain fatty acids with high-performance liquid chromatography coupled with an ultraviolet detector was developed and the pre-column derivatization by indole-3-acetic acid hydrazide was performed to improve the separation and detection. The conditions of the derivatization reaction were systematically investigated. Subsequently, the method was validated and the results showed a satisfactory linearity (linear regression coefficients > 0.9969), the limit of detection (4.0x10(-3)-1.9x10(-2) mu mol/L), precision (0.9%-7.3% for intra-day and 2.0%-9.8% for inter-day), recovery (90.0%-109.1% with relative standard deviation <7.7%) and stability (0.1%-3.3% for standard solution and 0.2%-3.9% for fecal sample). Finally, the established method was successfully applied to quantify short-chain and medium-chain fatty acids in the feces of healthy control and diabetic rats. Eleven kinds of short-chain and medium-chain fatty acids were detected and six of them showed a significant difference between the control group and the model group.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Determination of Short-Chain Fatty Acids and Lactic Acid in Biosamples by High Performance Liquid Chromatography with Pre-Column Derivatization
    Wang G.
    Huang W.
    Huo J.
    Yan M.
    Wu S.
    Hao Z.
    Wei Y.
    Shipin Kexue/Food Science, 2022, 43 (18): : 265 - 271
  • [2] Efficient procedure for pre-column derivatization of fatty acids with emphasis on short-chain carboxylic acids
    Czauderna, M.
    Kowalczyk, J.
    Niedzwiedzka, K. M.
    Mieczkowska, A.
    CHEMIA ANALITYCZNA, 2008, 53 (04): : 535 - 544
  • [3] A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Zinchenko, Alexandr A.
    Zhilyakova, Elena T.
    Novikov, Oleg O.
    ANALYTICAL METHODS, 2014, 6 (05) : 1475 - 1481
  • [4] PRE-COLUMN DERIVATIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ROSS, MSF
    JOURNAL OF CHROMATOGRAPHY, 1977, 141 (01): : 107 - 119
  • [5] QUANTITATION OF SHORT-CHAIN AND MEDIUM-CHAIN ACYLCARNITINES IN PLASMA BY RADIOISOTOPIC EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCHMIDTSOMMERFELD, E
    ZHANG, LY
    BOBROWSKI, PJ
    PENN, D
    ANALYTICAL BIOCHEMISTRY, 1995, 231 (01) : 27 - 33
  • [6] Determination of ethambutol in plasma by high-performance liquid chromatography after pre-column derivatization
    Chenevier, P
    Massias, L
    Gueylard, D
    Farinotti, R
    JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2): : 310 - 315
  • [7] HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY DETERMINATION OF ANILINES WITH FLUORESCENT DETECTION AND PRE-COLUMN DERIVATIZATION
    Al-Kindy, Salma M. Z.
    Al-Kalbani, Azza
    Al-Harasi, Ahmed F.
    Suliman, FakhrEldin O.
    Al-Lawati, Haider J.
    Al-Hamadi, Abdalla
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (01) : 48 - 59
  • [8] Determination of free amino acids in microalgae by high-performance liquid chromatography using pre-column fluorescence derivatization
    Rodriguez, JRB
    Reina, GG
    Rodriguez, JJS
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (06) : 335 - 336
  • [9] Determination of free amino acids in microalgae by high-performance liquid chromatography using pre-column fluorescence derivatization
    Department of Chemistry, Faculty of Marine Sciences, Univ. of Las Palmas de Gran Canaria, 35017 Las Palmas de G.C., Las Palmas, Spain
    不详
    BIOMED. CHROMATOGR., 6 (335-336):
  • [10] Determination of Short-chain Fatty Acids in Rat and Human Feces by High-Performance Liquid Chromatography with Electrochemical Detection
    Akira Kotani
    Yuji Miyaguchi
    Mototaka Kohama
    Takafumi Ohtsuka
    Taisei Shiratori
    Fumiyo Kusu
    Analytical Sciences, 2009, 25 : 1007 - 1011