Removal of levofloxacin and ciprofloxacin from aqueous solutions and an economic evaluation using the electrocoagulation process

被引:35
|
作者
Mohammed, Sabah J. [1 ]
M-Ridha, Mohanad Jasim [1 ]
Abed, Khalid M. [2 ,3 ]
Elgharbawy, Amal A. M. [4 ,5 ]
机构
[1] Univ Baghdad, Coll Engn, Dept Environm Engn, Baghdad, Iraq
[2] Univ Baghdad, Coll Engn, Dept Chem Engn, Baghdad, Iraq
[3] Univ Malaya, Dept Chem Engn, Fac Engn, Kuala Lumpur, Malaysia
[4] Int Islamic Univ Malaysia, Int Inst Halal Res & Training INHART, Kuala Lumpur, Malaysia
[5] Int Islamic Univ Malaysia, Dept Biotechnol Engn, Bioenvironm Engn Res Ctr BERC, Fac Engn, Kuala Lumpur, Malaysia
关键词
Antibiotics; stainless steel electrodes; economic evaluation; kinetic models; isotherm models; wastewater treatment; WASTE-WATER; ADSORPTION; DYE; DECOLORIZATION; OXIDATION; CARBON; TETRACYCLINE; CHROMIUM(VI); PRODUCTS; FLUORIDE;
D O I
10.1080/03067319.2021.1913733
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R-2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the chemical adsorption mechanism controlled the removal of CIP and LVX. The R-2 with CIP is 0.944, and LVX is 0.941. For binary system removal, efficiencies were 93.00, 90.10, and 96.30% for CIP, and 91.80, 96.10, and 92.97% for LVX, at the CIP ratio: LVX of 1:1, 1:4, and 4:1. The electrode consumption (ELC) and electrical energy consumption (EEC) were found at 0.208 g and 3.21 kWh(-3) for a single operation. The operating cost was estimated at 0.613 US$ m(-3).
引用
收藏
页码:3801 / 3819
页数:19
相关论文
共 50 条
  • [1] OPTIMIZATION OF LEVOFLOXACIN REMOVAL FROM AQUEOUS SOLUTION USING ELECTROCOAGULATION PROCESS BY RESPONSE SURFACE METHODOLOGY
    Mohammed, S. J.
    Mohammed-Ridha, M. J.
    IRAQI JOURNAL OF AGRICULTURAL SCIENCES, 2021, 52 (01): : 204 - 217
  • [2] PHENOL REMOVAL BY ELECTROCOAGULATION PROCESS FROM AQUEOUS SOLUTIONS
    Bazrafshan, Edris
    Biglari, Hamed
    Mahvi, Amir Hossein
    FRESENIUS ENVIRONMENTAL BULLETIN, 2012, 21 (02): : 364 - 371
  • [3] Ciprofloxacin Removing from Aqueous Solutions Using Batch Reactor Electrocoagulation Process with Aluminum Electrodes
    Majid, Raghad
    Samaka, Isra'a Sadi
    JOURNAL OF ECOLOGICAL ENGINEERING, 2023, 24 (09): : 364 - 372
  • [4] INVESTIGATION OF PROCESS PARAMETERS FOR THE REMOVAL OF DIMETHYL PHTHALATE FROM AQUEOUS SOLUTIONS USING ELECTROCOAGULATION
    Chiou, Huei-Lin
    Chou, Wei-Lung
    Chang, Ya-Chieh
    Lin, Chia-Hsiang
    Chiang, Hung-Hsiang
    FRESENIUS ENVIRONMENTAL BULLETIN, 2014, 23 (05): : 1166 - 1172
  • [5] Survey Electrocoagulation Process in Removal of Norfloxacin Antibiotic from Aqueous Solutions
    Balarak, Davoud
    Dashtizadeh, Mahdethe
    Oguike, Raphael Shadai
    Chandrika, Kethineni
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2020, 32 (03) : 53 - 60
  • [6] Removal of Hydrolyzable and Condensed Tannins from Aqueous Solutions by Electrocoagulation Process
    Hassoune, J.
    Tahiri, S.
    Aarfane, A.
    El Krati, M.
    Salhi, A.
    Azzi, M.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2017, 143 (06)
  • [7] Evaluation of electrocoagulation process for the removal of strontium and cesium from aqueous solution
    Kamaraj, Ramakrishnan
    Vasudevan, Subramanyan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 93 : 522 - 530
  • [8] Removal of Ciprofloxacin from Aqueous Solutions Using Pillared Clays
    Roca Jalil, Maria Eugenia
    Baschini, Miria
    Sapag, Karim
    MATERIALS, 2017, 10 (12):
  • [9] Humic acid removal from aqueous solutions by peroxi-electrocoagulation process
    Yazdanbakhsh, Ahmad Reza
    Kermani, Majid
    Komasi, Sanaz
    Aghayani, Ehsan
    Sheikhmohammadi, Amir
    ENVIRONMENTAL HEALTH ENGINEERING AND MANAGEMENT JOURNAL, 2015, 2 (02): : 53 - 58
  • [10] Optimization of the electrocoagulation process on the effectiveness of removal of Cefixime antibiotic from aqueous solutions
    Mostafaloo, Roqiyeh
    Yari, Ahmad Reza
    Mohammadi, Mohammad Javad
    Khaniabadi, Yusef Omidi
    Asadi-Ghalhari, Mahdi
    DESALINATION AND WATER TREATMENT, 2019, 144 : 138 - 144