Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia

被引:0
|
作者
Cao, Weifang [1 ,2 ,3 ]
Zhang, Suhua [3 ]
Liu, Qian [3 ]
Zhou, Jing [3 ]
Yuan, Xiaoyong [1 ,2 ]
机构
[1] Tianjin Med Univ, Clin Coll Ophthalmol, Tianjin 300070, Peoples R China
[2] Tianjin Eye Hosp, Tianjin Eye Inst, Tianjin Key Lab Ophthalmol & Visual Sci, Tianjin 300020, Peoples R China
[3] Shanxi Eye Hosp, Dept Cataract, Taiyuan 030002, Shanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Phakic intraocular lens; Moderate-to-high myopia; Refractive surgery; Dysfunctional lens index; PHAKIC INTRAOCULAR-LENS; REFRACTIVE OUTCOMES; DENSITOMETRY; ICL;
D O I
10.1007/s10792-023-02812-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundDysfunctional lens index (DLI) changing is rarely reported after implantable collamer lens (ICL) implantation. In the current research, we hope to investigate the changes of DLI by ray-tracing aberrometry before and after implantation of the posterior chamber phakic implantable collamer lens with a central artificial hole for patients with moderate-to-high myopia.MethodsThis retrospective, observational case series included 206 eyes of 104 patients with moderate-to-high myopia who underwent ICL V4c implantation. Data were collected on ocular indicators preoperatively and at 1 day, 1, 3, and 6 months postoperatively. The i-Trace Visual Functional Analyzer was used to assess the DLI measurement.ResultsThe overall values of safety index and efficacy index were both more than 1. Preoperatively, the mean spherical equivalent (SE) of included 206 eyes was - 10.77 & PLUSMN; 3.46 diopter (D). Then at 1-day postoperation, the mean SE was - 0.22 & PLUSMN; 0.55 D, and barely changed from 1 day to 6 months postoperatively. Although the endothelial parameters had no significant differences between preoperation and postoperation, the mean loss of endothelial cells was 0.74 & PLUSMN; 0.98% at 6 months. Regarding the vault, there was a significant difference between each time of follow-up (P < 0.001). The mean of the vault decreased 109.6 & PLUSMN; 13.5 & mu;m from 1-day post-op to 6 months post-op. The DLI values were 3.70, 9.26, 10.00, and 9.68 at baseline, 1, 3, and 6 months, respectively (P < 0.001), but no significant differences were found between 1, 3, and 6 months postoperatively (P > 0.05). The preoperative lnDLI showed a significant positive linear correlation (r = 0.621, P < 0.001) with the preoperative spherical equivalent (SE). The lnDLI was negatively correlated with the axial length (r = - 0.462, P < 0.001), corneal thickness (r = - 0.207, P = 0.003), preoperative LogMAR UDVA (r = - 0.189, P = 0.006), and preoperative LogMAR CDVA (r = - 0.306, P < 0.001).ConclusionsThe postoperative refractive parameters were confirmed excellent in efficacy, predictability, and stability in half a year. The DLI was significantly improved after the ICL V4c implantation in patients with moderate-to-high myopia and showed good stability during the follow-up periods. The DLI deserves a more comprehensive understanding and application in clinical services.
引用
收藏
页码:4111 / 4120
页数:10
相关论文
共 50 条
  • [41] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Ye, Yuhao
    Zhao, Jing
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (08) : 2763 - 2771
  • [42] The Effects of Implantable Collamer Lens ICL Implantation in High Myopia Patients' Mental Health
    Lin, Ye
    Luo, Shuke
    Lu, Qiang
    Pan, Xueke
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 121 - 126
  • [43] Posterior chamber collamer phakic intraocular lens implantation: Comparison of efficacy and safety for low and moderate-to-high myopia
    Pinto, Christophe
    Monteiro, Tiago
    Franqueira, Nuno
    Faria-Correia, Fernando
    Mendes, Jose
    Vaz, Fernando
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 894 - 901
  • [44] Quality of Life in High Myopia Implantable Collamer Lens Implantation versus Contact Lens Wear
    leong, Alvin
    Rubin, Gary S.
    Allan, Bruce D. S.
    OPHTHALMOLOGY, 2009, 116 (02) : 275 - 280
  • [45] Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study
    Elmohamady M.N.
    Abdelghaffar W.
    Ophthalmology and Therapy, 2017, 6 (2) : 343 - 349
  • [46] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    He, Tianrui
    Zhu, Yi
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [47] Comparison of Visual Outcomes and Optical Quality of Femtosecond Laser-Assisted SMILE and Visian Implantable Collamer Lens (ICL V4c) Implantation for Moderate to High Myopia: A Meta-analysis
    Chen, Di
    Zhao, Xinyu
    Chou, Yuyu
    Luo, Yan
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (06) : 332 - +
  • [48] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    Tianrui He
    Yi Zhu
    Jibo Zhou
    BMC Ophthalmology, 20
  • [49] Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study
    Wuqiang Luo
    Aruma Aruma
    Meiyan Li
    Jing Wang
    Jing Xie
    Xin Xiao
    Yang Shen
    Lingling Niu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 23
  • [50] Corneal Aberrometic changes after ICL V4C intraocular lens implantation
    Garcia Padilla, Luis Antonio
    Vera-Duarte, Guillermo Raul
    Ramirez-Miranda, Arturo J.
    Kahuam-Lopez, Nicolas
    Haro-Morlett, Luis
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    Muller Morales, Adolfo
    Rubio, Gustavo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)