Comparison of Femoral Component Rotation between Robotic-Assisted vs. Soft-Tissue Tensor Total Knee Arthroplasty with Anatomic Implants

被引:2
|
作者
Maciag, Bartosz M. M. [1 ]
Kordyaczny, Tomasz [1 ]
Maciag, Grzegorz J. J. [1 ]
Lapinski, Marcin [1 ]
Jegierski, Dawid [1 ]
Swiderek, Jakub [2 ]
Tsitko, Hanna [3 ]
Dorocinska, Monika [1 ]
Zarnovsky, Krystian [1 ]
Swiercz, Maciej [1 ]
Stepinski, Piotr [1 ]
Adamska, Olga [1 ]
Stolarczyk, Artur [1 ]
机构
[1] Med Univ Warsaw, Miedzyleski Specialist Hosp, Dept Orthoped & Rehabil, PL-04749 Warsaw, Masovian Voivod, Poland
[2] Med Univ Bialystok, Fac Med, PL-15089 Bialystok, Podlaskie Voivo, Poland
[3] Med Univ Lublin, Fac Med, PL-20059 Lublin, Lubelskie Voivo, Poland
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 05期
关键词
total knee replacement; rotation; Fuzion balancer; RATKA; computed tomography; osteoarthritis; soft tissue tensioner; NAVIO; measured resection technique; conventional total knee replacement; TRANSEPICONDYLAR AXIS; ALIGNMENT; PATIENT; SATISFACTION;
D O I
10.3390/medicina59050880
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic-assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher's exact, Kruskal-Wallis and Dwass-Steel-Crichtlow-Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0 degrees in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection
    Sultan, Assem A.
    Piuzzi, Nicolas
    Khlopas, Anton
    Chughtai, Morad
    Sodhi, Nipun
    Mont, Michael A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (12) : 925 - 927
  • [22] A comparison of pin site complications between large and small pin diameters in robotic-assisted total knee arthroplasty
    Desai, Sohil S.
    Kunes, Jennifer A.
    Held, Michael B.
    Ren, Mark
    deMeireles, Alirio J.
    Geller, Jeffrey A.
    Shah, Roshan P.
    Cooper, H. John
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [23] Comparison of Postoperative Anatomy Using Anatomic Total Shoulder Arthroplasty Versus Soft-Tissue Balancing Total Shoulder Arthroplasty
    Truntzer, Jeremy
    Vopat, Bryan
    Schwartz, Joel
    Anavian, Jack
    Barnds, Brandon L.
    Blaine, Theodore A.
    Green, Andrew
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (19) : 848 - 854
  • [24] A comparison of pin site complications between large and small pin diameters in robotic-assisted total knee arthroplasty
    Sohil S. Desai
    Jennifer A. Kunes
    Michael B. Held
    Mark Ren
    Alirio J. deMeireles
    Jeffrey A. Geller
    Roshan P. Shah
    H. John Cooper
    Journal of Experimental Orthopaedics, 10
  • [25] A Comparison between Robotic-assisted and Manual Implantation of Cementless Total Hip Arthroplasty
    Nakamura, Nobuo
    Sugano, Nobuhiko
    Nishii, Takashi
    Kakimoto, Akihiro
    Miki, Hidenobu
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (04) : 1072 - 1081
  • [26] Soft Tissue Releases Affect the Femoral Component Rotation Necessary to Create a Balanced Flexion Gap During Total Knee Arthroplasty
    Christensen, Christian P.
    Stewart, Allison H.
    Jacobs, Cale A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1528 - 1532
  • [27] Local Soft-Tissue Thickness vs. Body Mass Index as Predictors of Complications After Total Knee or Hip Arthroplasty
    Parikh, Sarthak
    Pannu, Tejbir S.
    Davis, Ty
    Gomez, Osmanny
    Corces, Arturo
    JBJS REVIEWS, 2023, 11 (11)
  • [28] A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty
    Olcott, CW
    Scott, RD
    JOURNAL OF ARTHROPLASTY, 2000, 15 (01): : 22 - 26
  • [29] No difference in clinical outcomes in robotic-assisted vs. computer-navigated total hip arthroplasty
    Haroun Haque
    Ameer Tabbaa
    Matthew Johnson
    Lydia Fu
    Afshin Razi
    Matthew L. Magruder
    Arthroplasty, 7 (1)
  • [30] Comparison of robotic-assisted total knee arthroplasty: an updated systematic review and meta-analysis
    Fu, Xinyu
    She, Yiming
    Jin, Guangwen
    Liu, Chengri
    Liu, Ze
    Li, Wei
    Jin, Ri
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)