3D-2D image registration in the presence of soft-tissue deformation in image-guided transbronchial interventions

被引:1
|
作者
Vijayan, R. [1 ]
Sheth, N. [1 ]
Mekki, L. [1 ]
Lu, A. [1 ]
Uneri, A. [1 ]
Sisniega, A. [1 ]
Magaraggia, J. [2 ]
Kleinszig, G. [2 ]
Vogt, S. [2 ]
Thiboutot, J. [3 ]
Lee, H. [3 ]
Yarmus, L. [3 ]
Siewerdsen, J. H. [1 ,4 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Siemens Healthineers, Erlangen, Germany
[3] Johns Hopkins Med Inst, Div Pulm & Crit Care Med, Baltimore, MD USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77070 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 01期
关键词
deformable image registration; 3D-2D image registration; pulmonary interventions; fluoroscopy; cone-beam CT; lung nodules; transbronchial biopsy; ENDOBRONCHIAL ULTRASOUND; RESPIRATORY MOTION; LUNG; CT; FLUOROSCOPY; BRONCHOSCOPY; FEASIBILITY; ALGORITHM; ACCURACY; BIOPSY;
D O I
10.1088/1361-6560/ac9e3c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. Target localization in pulmonary interventions (e.g. transbronchial biopsy of a lung nodule) is challenged by deformable motion and may benefit from fluoroscopic overlay of the target to provide accurate guidance. We present and evaluate a 3D-2D image registration method for fluoroscopic overlay in the presence of tissue deformation using a multi-resolution/multi-scale (MRMS) framework with an objective function that drives registration primarily by soft-tissue image gradients. Methods. The MRMS method registers 3D cone-beam CT to 2D fluoroscopy without gating of respiratory phase by coarse-to-fine resampling and global-to-local rescaling about target regions-of-interest. A variation of the gradient orientation ( GO iso). Phantom studies determined nominal algorithm parameters and capture range. Preclinical studies used a freshly deceased, ventilated porcine specimen to evaluate performance in the presence of real tissue deformation and a broad range of 3D-2D image mismatch. Results. Nominal algorithm parameters were identified that provided robust performance over a broad range of motion (0-20 mm), including an adaptive parameter selection technique to accommodate unknown mismatch in respiratory phase. The GO & PRIME; iso = 1.2 mm, compared to 6.2 mm for conventional GO. GO & PRIME;
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Simultaneous 3D-2D image registration and C-arm calibration: Application to endovascular image-guided interventions
    Mitrovic, Uros
    Pernus, Franjo
    Likar, Bostjan
    Spiclin, Ziga
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6433 - 6447
  • [2] Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery
    Ketcha, M. D.
    De Silva, T.
    Uneri, A.
    Kleinszig, G.
    Vogt, S.
    Wolinsky, J. -P.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [3] Multi-stage 3D-2D registration for correction of anatomical deformation in image-guided spine surgery
    Ketcha, M. D.
    De Silva, T.
    Uneri, A.
    Jacobson, M. W.
    Goerres, J.
    Kleinszig, G.
    Vogt, S.
    Wolinsky, J-P
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11): : 4604 - 4622
  • [4] Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation
    Otake, Yoshito
    Wang, Adam S.
    Stayman, J. Webster
    Uneri, Ali
    Kleinszig, Gerhard
    Vogt, Sebastian
    Khanna, A. Jay
    Gokaslan, Ziya L.
    Siewerdsen, Jeffrey H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (23): : 8535 - 8553
  • [5] 3D-2D Image Registration for Image-guided Surgery by Combining Normalized Cross Correlation and Laplacian Correlation
    Wang, Yang
    Xiao, Ye
    Xu, Congcong
    Yang, Bo
    Zheng, Wenfeng
    Liu, Shan
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 11 - 12
  • [6] A review of 3D/2D registration methods for image-guided interventions
    Markelj, P.
    Tomazvic, D.
    Likar, B.
    Pernus, F.
    [J]. MEDICAL IMAGE ANALYSIS, 2012, 16 (03) : 642 - 661
  • [7] Elastic 3D-2D Image Registration
    Striewski, Paul
    Wirth, Benedikt
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2022, 64 (05) : 443 - 462
  • [8] 3D-2D IMAGE REGISTRATION BY NONLINEAR REGRESSION
    Gouveia, Ana R.
    Metz, Coert
    Freire, Luis
    Klein, Stefan
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1343 - 1346
  • [9] Multi-Body 3D-2D Registration for Image-Guided Reduction of Pelvic Dislocation in Orthopaedic Trauma Surgery
    Han, R.
    Uneri, A.
    De Silva, T.
    Ketcha, M.
    Sheth, N.
    Kleinszig, G.
    Vogt, S.
    Osgood, G.
    Siewerdsen, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E298 - E298
  • [10] 3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms
    Mitrovic, Uros
    Likar, Bostjan
    Pernus, Franjo
    Spiclin, Ziga
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (02) : 193 - 202