Nano-mapping of vertical contact electrodes using synchrotron scanning photoelectron microscopy

被引:3
|
作者
Gu, Minseon [1 ]
Jang, Hansol [2 ]
Ahn, Hanyeol [1 ]
Kim, Hyuk Jin [1 ]
Hyun, Moon Seop [3 ]
Park, Yun Chang [3 ]
Kwak, In Hye [4 ,7 ]
Nam, Sangwoo [1 ,5 ]
Im, Jaehui [1 ,5 ]
Baik, Jaeyoon [4 ]
Shin, Hyun-Joon [2 ]
Han, Moonsup [1 ]
Kim, Gyungtae [3 ]
Chang, Young Jun [1 ,5 ,6 ]
机构
[1] Univ Seoul, Dept Phys, Seoul 02504, South Korea
[2] Chungbuk Natl Univ, Dept Phys, Cheongju 28644, South Korea
[3] Natl NanoFab Ctr NNFC, Daejeon 34141, South Korea
[4] POSTECH, Beamline Res Div, Pohang Accelerator Lab, Pohang 37673, South Korea
[5] Univ Seoul, Dept Smart Cities, Seoul 02504, South Korea
[6] Univ Seoul, Dept Intelligent Semicond Engn, Seoul 02504, South Korea
[7] Korea Basic Sci Inst KBSI, Res Ctr Mat Anal, Daejeon 34133, South Korea
关键词
Scanning photoelectron microscopy (SPEM); High aspect ratio contact hole; Nanoscale inspection methodology; Focused X-ray beam; HOLES;
D O I
10.1016/j.apsusc.2024.159605
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
With the rise in demand for high aspect ratio hole etching in semiconductor device fabrication, developing efficient inspection methods to detect etching failures is increasingly vital. Such failures can compromise the reliability of electrical connections of contact holes in highly sophisticated 3D semiconductor geometries. In this study, we present a nanoscale inspection technique employing synchrotron -based scanning photoelectron microscopy (SPEM) to assess the electrical connectivity of contact holes. Samples were systematically prepared with an array of contact holes of varying sizes. To simulate etching failure, a residual silicon oxide layer was deliberately left to induce the binding energy shift in photoelectron peak positions due to electrical charging. By obtaining W 4f and Si 2p spectra for the W -filled and W -unfilled structures, respectively, we objectively determined the electrical states of the contact holes. With its focused X-ray beams, SPEM has demonstrated its suitability for investigating the electrical connectivity of individual contact holes at the nanoscale. SPEM possesses the additional capability of non-destructive imaging the thickness of buried insulators inside an individual contact hole. Our results cast potential application of SPEM as a nanoscale inspection methodology for advanced semiconductor manufacturing.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Imaging the lateral shift of a quantum point contact using scanning gate microscopy
    Schnez, S.
    Roessler, C.
    Ihn, T.
    Ensslin, K.
    Reichl, C.
    Wegscheider, W.
    PHYSICAL REVIEW B, 2011, 84 (19)
  • [32] Nano-Localized Thermal Analysis and Mapping of Surface and Sub-Surface Thermal Properties Using Scanning Thermal Microscopy (SThM)
    Pereira, Maria J.
    Amaral, Joao S.
    Silva, Nuno J. O.
    Amaral, Vitor S.
    MICROSCOPY AND MICROANALYSIS, 2016, 22 (06) : 1270 - 1280
  • [33] Direct Observation of Contact Electrification Effects at Nanoscale Using Scanning Probe Microscopy
    Kim, Jong Hun
    Jeong, Jinhyeok
    Kong, Dae Sol
    Yoon, Hongyeon
    Cho, Hunyoung
    Jung, Jong Hoon
    Park, Jeong Young
    ADVANCED MATERIALS INTERFACES, 2024, 11 (06)
  • [34] Local voltage contrast changes in MOSFET using scanning electron microscopy with photoelectron beam technology
    Sato, Daiki
    Arakawa, Yuta
    Niimi, Kotaro
    Fukuroi, Keika
    Tajiri, Yutaro
    Koizumi, Atsushi
    Shikano, Haruka
    Iijima, Hokuto
    Nishitani, Tomohiro
    Honda, Yoshio
    Amano, Hiroshi
    METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVIII, 2024, 12955
  • [35] TEMPERATURE STUDY OF EMBEDDED CONTACT SENSOR FOR HDDS BY USING SCANNING THERMAL MICROSCOPY
    Furukawa, Masaru
    Xu, Junguo
    Li, Jianhua
    Hashimoto, Kiyoshi
    Satou, Makoto
    PROCEEDINGS OF THE ASME CONFERENCE ON INFORMATION STORAGE AND PROCESSING SYSTEMS, 2014, 2014,
  • [36] Nanoscale chemical imaging using synchrotron x-ray enhanced scanning tunneling microscopy
    Rose, Volker
    Freeland, John W.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 445 - 448
  • [37] Correction for piezoelectric creep in scanning probe microscopy images using polynomial mapping
    Trawick, ML
    Megens, M
    Harrison, C
    Angelescu, DE
    Vega, DA
    Chaikin, PM
    Register, RA
    Adamson, DH
    SCANNING, 2003, 25 (01) : 25 - 33
  • [38] Mapping Electron Transfer at MoS2 Using Scanning Electrochemical Microscopy
    Ritzert, Nicole L.
    Szalai, Veronika A.
    Moffat, Thomas P.
    LANGMUIR, 2018, 34 (46) : 13864 - 13870
  • [39] Local elasticity mapping of aluminum matrix composites using scanning acoustic microscopy
    Kordatou, T. Z.
    Tragazikis, I. K.
    Matikas, T. E.
    SMART MATERIALS AND NONDESTRUCTIVE EVALUATION FOR ENERGY SYSTEMS 2017, 2017, 10171
  • [40] Spatial mapping of the mechanical properties of the living retina using scanning force microscopy
    Franze, Kristian
    Francke, Mike
    Guenter, Katrin
    Christ, Andreas F.
    Koerber, Nicole
    Reichenbach, Andreas
    Guck, Jochen
    SOFT MATTER, 2011, 7 (07) : 3147 - 3154