Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up

被引:4
|
作者
Rashid, Mustafa S. [1 ]
Cunningham, Lindsay [1 ]
Shields, David W. [1 ]
Walton, Michael J. [1 ]
Monga, Puneet [1 ]
Bale, Richard S. [1 ]
Trail, Ian A. [1 ]
机构
[1] Wrightington Hosp, Dept Orthopaed Surg, Wigan, Lancs, England
关键词
Custom; 3D-printed; complex; shoulder; replacement; arthroplasty; revision; HEMIARTHROPLASTY;
D O I
10.1016/j.jse.2023.04.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study is to report the clinical and radiologic outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D-printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up.Methods: Following ethical approval, patients were identified and invited to participate. Inclusion criteria were (1) severe glenoid bone loss necessitating the need for custom implants and (2) patients with definitive glenoid and humeral components implanted more than 2 years prior. Included patients underwent clinical assessment using the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and the quick Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH). Radiographic assessment included anteroposterior and axial projections. Patients were invited to attend a computed tomography (CT) scan to confirm osseointegration. Statistical analysis used descriptive statistics (mean and standard deviation [SD]) and paired t test for parametric data.Results: Eleven patients declined to participate. Five patients were deceased prior to study commencement, leaving 42 remaining pa-tients in this analysis. Three patients had revision surgery before the 2-year follow-up; of these, 2 retained their custom glenoid com-ponents. Mean follow-up was 31.6 months from surgery (range 24-52 months). All 4 scores improved: OSS from a mean 15 (SD 8.4) to 36 (SD 12) (P < .001), Constant-Murley score from a mean 15 (SD 11.2) to 52 (SD 20.1) (P < .001), QuickDASH from a mean 70 (SD 21) to 31 (SD 24.8) (P = .004), and the ASES score from a mean 22 (SD 17.8) to 71 (SD 23.3) (P = .007). Radiologic evaluation demonstrated good osseointegration in all but 1 included patient.Conclusion: The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex cohort. Large complex glenoid bone defects can be managed successfully with custom 3D-printed glenoid components.
引用
收藏
页码:2017 / 2026
页数:10
相关论文
共 48 条
  • [31] Efficacy and safety of a 3D-printed arthrodesis prosthesis for reconstruction after resection of the proximal humerus: preliminary outcomes with a minimum 2-year follow-up
    Haijie Liang
    Wei Guo
    Yi Yang
    Dasen Li
    Rongli Yang
    Xiaodong Tang
    Taiqiang Yan
    BMC Musculoskeletal Disorders, 23
  • [32] Efficacy and safety of a 3D-printed arthrodesis prosthesis for reconstruction after resection of the proximal humerus: preliminary outcomes with a minimum 2-year follow-up
    Liang, Haijie
    Guo, Wei
    Yang, Yi
    Li, Dasen
    Yang, Rongli
    Tang, Xiaodong
    Yan, Taiqiang
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [33] Clinical outcomes following reverse shoulder arthroplasty-allograft composite for revision of failed arthroplasty associated with proximal humeral bone deficiency: 2-to 15-year follow-up
    Cox, Jacob L.
    McLendon, Paul B.
    Christmas, Kaitlyn N.
    Simon, Peter
    Mighell, Mark A.
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (05) : 900 - 907
  • [34] Minimally Invasive Chevron-Akin for Correction of Moderate and Severe Hallux Valgus Deformities: Clinical and Radiologic Outcomes With a Minimum 2-Year Follow-up
    de Carvalho, Kepler Alencar Mendes
    Baptista, Andre Donato
    de Cesar Netto, Cesar
    Johnson, Anne H.
    Dalmau-Pastor, Miki
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (10) : 1317 - 1330
  • [35] Results of Using a "2-in-1" Single-Stage Revision Total Knee Arthroplasty for Infection with Associated Bone Loss: Prospective 2-Year Follow-Up
    Holland, George
    Brown, Gavin
    Goudie, Stuart
    Brenkel, Ivan
    Walmsley, Philip J.
    JOURNAL OF KNEE SURGERY, 2021, 34 (05) : 526 - 532
  • [36] Cup-Cage Construct for Treatment of Severe Acetabular Bone Loss in Revision Total Hip Arthroplasty: Clinical and Radiographic Outcomes at a Mean Follow-Up of 7.7 Years
    Chaudhry, Faran
    Daud, Anser
    Greenberg, Arieh
    Braunstein, Doris
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (10): : 2555 - 2560
  • [37] Comparative study of 145° onlay curved stem versus 155° inlay straight stem reverse shoulder arthroplasty: clinical and radiographic results with a minimum 2-year follow-up
    Giordano, Matthew C.
    Corona, Katia
    Morris, Brent J.
    Mocini, Fabrizio
    Saturnino, Luca
    Cerciello, Simone
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (10) : 2089 - 2095
  • [38] Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2-to 7-year follow-up study
    Levy, Ofer
    Narvani, Ali
    Hous, Nir
    Abraham, Ruben
    Relwani, Jai
    Pradhan, Riten
    Bruguera, Juan
    Sforza, Giuseppe
    Atoun, Ehud
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (08) : 1362 - 1370
  • [39] Minimum 5 year follow-up of clinical and radiographic results of cemented acetabular components with an interface bioactive bone cement technique in primary cemented total hip arthroplasty
    Shuichi Miyamoto
    Satoshi Iida
    Chiho Suzuki
    Takushi Nakatani
    Yuya Kawarai
    Junichi Nakamura
    Sumihisa Orita
    Seiji Ohtori
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 139 - 147
  • [40] Minimum 5 year follow-up of clinical and radiographic results of cemented acetabular components with an interface bioactive bone cement technique in primary cemented total hip arthroplasty
    Miyamoto, Shuichi
    Iida, Satoshi
    Suzuki, Chiho
    Nakatani, Takushi
    Kawarai, Yuya
    Nakamura, Junichi
    Orita, Sumihisa
    Ohtori, Seiji
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (01) : 139 - 147