Microplastics in Australian indoor air: Abundance, characteristics, and implications for human exposure

被引:42
|
作者
Perera, Kushani [1 ]
Ziajahromi, Shima [1 ]
Nash, Susan Bengtson [2 ]
Leusch, Frederic D. L. [1 ]
机构
[1] Griffith Univ, Australian Rivers Inst, Sch Environm & Sci, Southport, Qld 4222, Australia
[2] Griffith Univ, Ctr Planetary Hlth & Food Secur, Sch Environm & Sci, Southport, Qld 4222, Australia
关键词
Active sampling; Atmosphere; Fiber; Indoor air; Microplastics; FIBERS; DUST;
D O I
10.1016/j.scitotenv.2023.164292
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Studies on airborne microplastics (AMPs) have reported higher abundance of AMPs in indoor air compared to out-doors. Most people spend more time indoors compared to outdoors, and it is therefore important to identify and quan-tify AMPs in indoor air to understand human exposure to AMPs. This exposure can vary among different individuals as they spend their time in different locations and different activity levels, and thus experience different breathing rates. In this study, AMPs ranging from 20-5000 & mu;m were sampled across different indoor sites of Southeast Queensland using an active sampling technique. The highest indoor MP concentration was observed at a childcare site (2.25 & PLUSMN; 0.38 particles/m3), followed by an office (1.20 & PLUSMN; 0.14 particles/m3) and a school (1.03 & PLUSMN; 0.40 particles/m3). The lowest indoor MP concentration was observed inside a vehicle (0.20 & PLUSMN; 0.14 particles/m3), comparable to outdoor concentrations. The only shapes observed were fibers (98%) and fragments. MP fibers ranged from 71 to 4950 & mu;m in length. Polyethylene terephthalate was the prominent polymer type at most sites. Using our mea-sured airborne concentrations as inhaled air concentrations, we calculated the annual human exposure levels to AMPs using scenario-specific activity levels. Males between the ages of 18 to 64 were calculated to have the highest AMP exposure at 3187 & PLUSMN; 594 particles/year, followed by males & GE;65 years at 2978 & PLUSMN; 628 particles/ year. The lowest exposure of 1928 & PLUSMN; 549 particles/year was calculated for females between the ages of 5 to 17. This study provides the first report on AMPs for various types of indoor locations where individuals spend most of their time. Considering acute, chronic, industrial, and individual susceptibility, more detailed human inhalation expo-sure levels to AMPs should be estimated for a realistic appraisal of the human health risk, including how much of the inhaled particles are exhaled. Synopsis: Limited research exists on the occurrence and the associated human exposure levels to AMPs in indoor loca-tions where people spend most of their time. This study reports on the occurrence of AMPs at indoor locations and associated exposure levels using scenario-specific activity levels.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Microplastics exposure: implications for human fertility, pregnancy and child health
    Zurub, Rewa E.
    Cariaco, Yusmaris
    Wade, Michael G.
    Bainbridge, Shannon A.
    FRONTIERS IN ENDOCRINOLOGY, 2024, 14
  • [22] Indoor air and human exposure assessment - needs and approaches
    Kotzias, D
    EXPERIMENTAL AND TOXICOLOGIC PATHOLOGY, 2005, 57 : 5 - 7
  • [23] Human exposure to indoor air pollution in Ethiopian households
    Asefa, Elsai Mati
    Mergia, Mekuria Teshome
    HELIYON, 2022, 8 (11)
  • [24] Simulating human exposure to indoor airborne microplastics using a Breathing Thermal Manikin
    Alvise Vianello
    Rasmus Lund Jensen
    Li Liu
    Jes Vollertsen
    Scientific Reports, 9
  • [25] Review of microplastics in the indoor environment: Distribution, human exposure and potential health impacts
    Dewika, M.
    Markandan, Kalaimani
    Irfan, N. Ahmad
    Abdah, Muhammad Amirul Aizat Mohd
    Ruwaida, J. Nor
    Sara, Y. Y.
    Khalid, Mohammad
    CHEMOSPHERE, 2023, 324
  • [26] Microplastics in indoor and outdoor environments in China: Characteristic and human exposure risk assessment
    Zheng, Han
    Guo, Huibin
    Fu, Haiyan
    Yao, Kaixing
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2024, 287
  • [27] Simulating human exposure to indoor airborne microplastics using a Breathing Thermal Manikin
    Vianello, Alvise
    Jensen, Rasmus Lund
    Liu, Li
    Vollertsen, Jes
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [28] Indoor Airborne Microplastics: Human Health Importance and Effects of Air Filtration and Turbulence
    Gaylarde, Christine C.
    Neto, Jose Antonio Baptista
    da Fonseca, Estefan M.
    MICROPLASTICS, 2024, 3 (04): : 653 - 670
  • [29] A review of organophosphate esters in indoor dust, air, hand wipes and silicone wristbands: Implications for human exposure
    Hou, Minmin
    Shi, Yali
    Na, Guangshui
    Cai, Yaqi
    ENVIRONMENT INTERNATIONAL, 2021, 146
  • [30] Synthetic Microplastics in UK tap and bottled water; Implications for human exposure
    Al-Mansoori, Muneera
    Stephenson, Mia
    Harrad, Stuart
    Abdallah, Mohamed Abou-Elwafa
    EMERGING CONTAMINANTS, 2025, 11 (01)