Integrating vascular access surveillance with clinical monitoring for stenosis prediction

被引:0
|
作者
Wu, Chung-Kuan [1 ,2 ]
Lin, Chia-Hsun [2 ,3 ]
机构
[1] Shin Kong Wu Ho Su Mem Hosp, Dept Internal Med, Div Nephrol, Taipei, Taiwan
[2] Fu Jen Catholic Univ, Sch Med, New Taipei, Taiwan
[3] Shin Kong Wu Ho Su Mem Hosp, Dept Surg, Div Cardiovasc Surg, 95 Wenchang Rd, Taipei 111045, Taiwan
关键词
Arteriovenous fistula; Arteriovenous graft; Clinical monitoring; Vascular access stenosis; BLOOD-FLOW SURVEILLANCE; REDUCES THROMBOSIS; FISTULA PATENCY; HEMODIALYSIS; COMPLICATIONS;
D O I
10.1007/s40620-023-01799-2
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Arteriovenous fistula and arteriovenous graft are the most common types of vascular access for dialysis; stenosis and thrombosis are major complications leading to access failure and to an incresed risk of mortality. The aim of the present study was to assess the results of integrating strict vascular access blood flow surveillance with routine clinical monitoring for predicting vascular access stenosis in chronic hemodialysis patients.Methods In this retrospective study, chronic dialysis patients with arteriovenous fistula or arteriovenous graft were included from a setting in which all patients underwent quarterly blood flow surveillance in 2017. The results of blood flow surveillance were confirmed by thorough physical examination. Predictive performance of blood flow surveillance models in detecting stenosis in patients with arteriovenous fistula or arteriovenous graft was evaluated. The predictive performance of the quarterly blood flow surveillance model was described by confusion matrix. Differences in accuracy, positive predictive value (PPV), and negative predictive value (NPV) between blood flow surveillance models with distinct blood flow thresholds were evaluated.Results Of 397 included patients, 336 had an arteriovenous fistula and 61 had an arteriovenous graft. In 2017, 106 percutaneous transluminal angioplasty procedures were performed in patients with an arteriovenous fistula, and 63 in patients with an arteriovenous graft. The results revealed similar predictive performance of surveillance models using an absolute blood flow threshold of < 500 or < 400 mL/min in predicting stenosis in patients with arteriovenous fistula. Blood flow surveillance models for patients with an arteriovenous fistula had significantly higher accuracy than those for patients with an arteriovenous graft. Furthermore, the use of a relative threshold, defined as blood flow < 1000 mL/min and a 25% decline in blood flow, did not affect the predictive performance of blood flow surveillance models.Conclusion Blood flow surveillance models using thresholds of < 400 and < 600 mL/min, followed by thorough physical examination, showed an accuracy of 91.54% and 72.15% in predicting stenosis in patients with arteriovenous fistula and arteriovenous graft, respectively. These two blood flow surveillance models may be integrated with routine clinical monitoring to improve early detection and treatment of stenosis in hemodialysis patients.
引用
收藏
页码:461 / 470
页数:10
相关论文
共 50 条
  • [21] Assessment of stenosis in vascular access grafts
    Van Tricht, I
    De Wachter, D
    Vanhercke, D
    Tordoir, J
    Verdonck, P
    ARTIFICIAL ORGANS, 2004, 28 (07) : 617 - 622
  • [22] Hemodialysis vascular access dysfunction: From clinical stenosis to specific cell types
    Roy-Chaudhury, P
    Munda, R
    Edwards, J
    Kelly, BS
    JOURNAL OF NEPHROLOGY, 2003, 16 (02) : 277 - 277
  • [23] Vascular access surveillance: No benefit? Reply
    Tonelli, Marcello
    James, Mathew
    Wiebe, Natasha
    Hemmelgarm, Brenda
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 52 (03) : 628 - 629
  • [24] Routine surveillance in vascular access for hemodialysis
    Henry, Mitchell L.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (05) : 545 - 548
  • [25] Vascular access surveillance: an ongoing controversy
    Paulson, William D.
    Moist, Louise
    Lok, Charmaine E.
    KIDNEY INTERNATIONAL, 2012, 81 (02) : 132 - 142
  • [26] Controversial Vascular Access Surveillance Mandate
    Paulson, William D.
    Work, Jack
    SEMINARS IN DIALYSIS, 2010, 23 (01) : 92 - 94
  • [27] VASCULAR ACCESS STENOSIS: INTIMA MEDIA THICKNESS ULTRASOUND SURVEILLANCE. FROM BASICS TO A RISK PREDICTOR?
    Ibeas, Jose
    Vidal, Marta
    Vallespin, Joaquim
    Jose Amengual, Maria
    Merino, Jana
    Orellana, Ruth
    Sanfeliu, Isabel
    Rodriguez-Jornet, Angel
    Vinuesa, Xavier
    Marquina, Dolors
    Xirinachs, Mercedes
    Sanchez, Estrella
    Moya, Carmen
    Ramirez, Josefa
    Rey, Merce
    Gimenez, Antonio
    Garcia, Manuel
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 236 - 237
  • [28] Monitoring vascular access flow
    Lindsay, RM
    Leypoldt, JK
    ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (03): : 273 - 277
  • [29] Vascular access: care and monitoring
    Pengloan, J
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (06) : 1141 - 1142
  • [30] Monitoring techniques of vascular access
    Segal, JH
    Weitzel, WF
    HEMODIALYSIS VASCULAR ACCESS AND PERITONEAL DIALYSIS ACCESS, 2004, 142 : 216 - 227